Certificate holders

Subtype

WWC 100 H/X

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
041-K001-31 / 1
Certification Body
BRE Global Limited
Subtype title
WWC 100 H/X
Driving energy
n/a
Heat Pump Type
Water/Water
Refrigerant
R407c
Mass of Refrigerant

2,950 kg

Certification Date
06.09.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

WWC 100H/X
Configure model
Model name
WWC 100H/X
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.00 kW

9.00 kW

El input

1.96 kW

2.92 kW

COP

5.60

3.08

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

174 %

Prated

11.00 kW

9.93 kW

SCOP

5.99

4.56

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.02 kW

10.09 kW

COP Tj = -7°C

5.62

3.52

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

11.14 kW

10.63 kW

COP Tj = +2°C

6.01

4.51

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

11.25 kW

10.95 kW

COP Tj = +7°C

6.39

5.33

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

11.35 kW

11.27 kW

COP Tj = 12°C

6.70

6.32

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

11.00 kW

9.93 kW

COP Tj = Tbiv

5.56

3.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

9.93 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.56

3.29

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

10 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3796 kWh

4499 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

233 %

176 %

Prated

11.00 kW

9.93 kW

SCOP

6.01

4.59

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.00 kW

9.93 kW

COP Tj = +2°C

5.56

3.29

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

11.12 kW

10.41 kW

COP Tj = +7°C

5.93

4.07

Cdh Tj = +7 °C

1.00

1.00

Pdh Tj = 12°C

11.28 kW

11.05 kW

COP Tj = 12°C

6.52

5.65

Cdh Tj = +12 °C

0.99

1.00

Pdh Tj = Tbiv

11.00 kW

9.93 kW

COP Tj = Tbiv

5.56

3.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

9.93 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.56

3.29

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2443 kWh

2887 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

239 %

182 %

Prated

11.00 kW

9.93 kW

SCOP

6.18

4.74

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

11.16 kW

10.52 kW

COP Tj = -7°C

6.09

4.28

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

11.25 kW

10.89 kW

COP Tj = +2°C

6.42

5.18

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

11.32 kW

11.16 kW

COP Tj = +7°C

6.66

6.00

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

11.34 kW

11.37 kW

COP Tj = 12°C

6.53

6.63

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

11.00 kW

9.93 kW

COP Tj = Tbiv

5.56

3.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

9.93 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.56

3.29

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4389 kWh

5165 kWh

Pdh Tj = -15°C (if TOL<-20°C)

0.01

0.01

COP Tj = -15°C (if TOL<-20°C)

0.01

0.01

Cdh Tj = -15 °C

1.00

1.00