Certificate holders

Subtype

THERMOR Alféa Extensa A.I. size 13

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-SC0226-19
Certification Body
RISE CERT
Subtype title
THERMOR Alféa Extensa A.I. size 13
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,500 kg

Certification Date
05.06.2019
Testing basis
n/a
Phase-out Date
16.04.2026
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

THERMOR Alféa Extensa A.I. 13 Phasing out on 16.04.2026
Configure model
Model name
THERMOR Alféa Extensa A.I. 13
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
16.04.2026

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

14.01 kW

7.84 kW

El input

3.50 kW

3.25 kW

COP

4.00

2.41

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

151 %

109 %

Prated

11.00 kW

8.00 kW

SCOP

3.85

2.80

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.00 kW

8.20 kW

COP Tj = -7°C

2.60

1.90

Pdh Tj = +2°C

6.10 kW

5.00 kW

COP Tj = +2°C

3.70

2.70

Pdh Tj = +7°C

6.20 kW

5.90 kW

COP Tj = +7°C

5.30

3.80

Pdh Tj = 12°C

7.40 kW

7.00 kW

COP Tj = 12°C

6.90

4.80

Pdh Tj = Tbiv

10.00 kW

8.20 kW

COP Tj = Tbiv

2.60

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.00 kW

8.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.90

0.90

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

45 W

22 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.30 kW

1.30 kW

Annual energy consumption Qhe

6062 kWh

6842 kWh