Certificate holders

Subtype

THERMOR Alféa Excellia A.I. size 14

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-SC0217-19
Certification Body
RISE CERT
Subtype title
THERMOR Alféa Excellia A.I. size 14
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,500 kg

Certification Date
05.06.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

THERMOR Alféa Excellia Duo A.I. 14
Configure model
Model name
THERMOR Alféa Excellia Duo A.I. 14
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.50 kW

9.48 kW

El input

3.23 kW

3.95 kW

COP

4.18

2.40

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

12.50 kW

11.30 kW

SCOP

3.77

2.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

10.00 kW

COP Tj = -7°C

2.50

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.70 kW

6.10 kW

COP Tj = +2°C

3.60

2.80

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.20 kW

5.90 kW

COP Tj = +7°C

5.40

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.30 kW

7.10 kW

COP Tj = 12°C

6.90

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.10 kW

10.00 kW

COP Tj = Tbiv

2.50

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

8 W

8 W

PTO

72 W

25 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.00 kW

Annual energy consumption Qhe

6824 kWh

8041 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

88 %

COP

2.25

Heating up time

0:46 h:min

Standby power input

40.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

250 l

THERMOR Alféa Excellia A.I. 14
Configure model
Model name
THERMOR Alféa Excellia A.I. 14
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.50 kW

9.48 kW

El input

3.23 kW

3.95 kW

COP

4.18

2.40

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

69 dB(A)

69 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

113 %

Prated

12.50 kW

11.30 kW

SCOP

3.77

2.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.10 kW

10.00 kW

COP Tj = -7°C

2.50

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.70 kW

6.10 kW

COP Tj = +2°C

3.60

2.80

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.20 kW

5.90 kW

COP Tj = +7°C

5.40

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.30 kW

7.10 kW

COP Tj = 12°C

6.90

5.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.10 kW

10.00 kW

COP Tj = Tbiv

2.50

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.80 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

8 W

8 W

PTO

72 W

25 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.70 kW

2.00 kW

Annual energy consumption Qhe

6824 kWh

8041 kWh