Certificate holders

Subtype

F1x55-6

Certificate Holder
Nibe AB
Box 14
S-28521 Markaryd
Sweden
Registration number
012-047 / issue 2
Certification Body
RISE CERT
Subtype title
F1x55-6
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R407c
Mass of Refrigerant

1,160 kg

Certification Date
12.12.2023
Testing basis
EN 14511:2013, EN 16147:2011, EN 14825:2013, EN 12102:2013
Generate PDF Export model CSV Download certificate
  • Number of models 8

Models

F1155-6 1x230
Configure model
Model name
F1155-6 1x230
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.15 kW

2.78 kW

El input

0.67 kW

0.93 kW

COP

4.72

2.99

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

157 %

Prated

5.50 kW

5.50 kW

SCOP

5.48

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.40 kW

3.40 kW

COP Tj = -7°C

5.17

3.77

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.10 kW

2.10 kW

COP Tj = +2°C

5.91

4.51

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.40 kW

1.40 kW

COP Tj = +7°C

6.36

5.12

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

4.15

4.81

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.40 kW

5.50 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2481 kWh

3287 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

150 %

Prated

5.50 kW

5.50 kW

SCOP

5.20

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

4.37

3.06

Pdh Tj = +2°C

3.10 kW

3.00 kW

COP Tj = +2°C

5.24

3.97

Pdh Tj = +7°C

2.00 kW

2.00 kW

COP Tj = +7°C

5.92

4.63

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

5.95

4.86

Pdh Tj = Tbiv

5.40 kW

5.40 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2188 kWh

2875 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

3.82 kW

El input

0.66 kW

1.00 kW

COP

6.49

3.83

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

282 %

222 %

Prated

7.00 kW

7.00 kW

SCOP

7.25

5.75

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

4.30 kW

COP Tj = -7°C

7.00

5.39

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

7.83

6.21

Pdh Tj = +7°C

1.80 kW

1.80 kW

COP Tj = +7°C

8.14

6.85

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.70

6.64

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3005 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

214 %

Prated

7.00 kW

7.00 kW

SCOP

6.95

5.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.30 kW

COP Tj = -7°C

6.07

4.52

Pdh Tj = +2°C

3.90 kW

3.90 kW

COP Tj = +2°C

7.09

5.62

Pdh Tj = +7°C

2.50 kW

2.50 kW

COP Tj = +7°C

7.84

6.34

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.97

6.57

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.97

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2078 kWh

2611 kWh

F1155-6 PC 1x230
Configure model
Model name
F1155-6 PC 1x230
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.15 kW

2.78 kW

El input

0.67 kW

0.93 kW

COP

4.72

2.99

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

157 %

Prated

5.50 kW

5.50 kW

SCOP

5.48

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.40 kW

3.40 kW

COP Tj = -7°C

5.17

3.77

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.10 kW

2.10 kW

COP Tj = +2°C

5.91

4.51

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.40 kW

1.40 kW

COP Tj = +7°C

6.36

5.12

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

4.15

4.81

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.40 kW

5.50 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2481 kWh

3287 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

150 %

Prated

5.50 kW

5.50 kW

SCOP

5.20

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

4.37

3.06

Pdh Tj = +2°C

3.10 kW

3.00 kW

COP Tj = +2°C

5.24

3.97

Pdh Tj = +7°C

2.00 kW

2.00 kW

COP Tj = +7°C

5.92

4.63

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

5.95

4.86

Pdh Tj = Tbiv

5.40 kW

5.40 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2188 kWh

2875 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

3.82 kW

El input

0.66 kW

1.00 kW

COP

6.49

3.83

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

282 %

222 %

Prated

7.00 kW

7.00 kW

SCOP

7.25

5.75

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

4.30 kW

COP Tj = -7°C

7.00

5.39

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

7.83

6.21

Pdh Tj = +7°C

1.80 kW

1.80 kW

COP Tj = +7°C

8.14

6.85

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.70

6.64

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3005 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

214 %

Prated

7.00 kW

7.00 kW

SCOP

6.95

5.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.30 kW

COP Tj = -7°C

6.07

4.52

Pdh Tj = +2°C

3.90 kW

3.90 kW

COP Tj = +2°C

7.09

5.62

Pdh Tj = +7°C

2.50 kW

2.50 kW

COP Tj = +7°C

7.84

6.34

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.97

6.57

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.97

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2078 kWh

2611 kWh

F1155-6 3x400
Configure model
Model name
F1155-6 3x400
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.15 kW

2.78 kW

El input

0.67 kW

0.93 kW

COP

4.72

2.99

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

157 %

Prated

5.50 kW

5.50 kW

SCOP

5.48

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.40 kW

3.40 kW

COP Tj = -7°C

5.17

3.77

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.10 kW

2.10 kW

COP Tj = +2°C

5.91

4.51

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.40 kW

1.40 kW

COP Tj = +7°C

6.36

5.12

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

4.15

4.81

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.40 kW

5.50 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2481 kWh

3287 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

150 %

Prated

5.50 kW

5.50 kW

SCOP

5.20

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

4.37

3.06

Pdh Tj = +2°C

3.10 kW

3.00 kW

COP Tj = +2°C

5.24

3.97

Pdh Tj = +7°C

2.00 kW

2.00 kW

COP Tj = +7°C

5.92

4.63

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

5.95

4.86

Pdh Tj = Tbiv

5.40 kW

5.40 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2188 kWh

2875 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

3.82 kW

El input

0.66 kW

1.00 kW

COP

6.49

3.83

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

282 %

222 %

Prated

7.00 kW

7.00 kW

SCOP

7.25

5.75

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

4.30 kW

COP Tj = -7°C

7.00

5.39

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

7.83

6.21

Pdh Tj = +7°C

1.80 kW

1.80 kW

COP Tj = +7°C

8.14

6.85

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.70

6.64

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3005 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

214 %

Prated

7.00 kW

7.00 kW

SCOP

6.95

5.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.30 kW

COP Tj = -7°C

6.07

4.52

Pdh Tj = +2°C

3.90 kW

3.90 kW

COP Tj = +2°C

7.09

5.62

Pdh Tj = +7°C

2.50 kW

2.50 kW

COP Tj = +7°C

7.84

6.34

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.97

6.57

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.97

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2078 kWh

2611 kWh

F1155-6 PC 3x400
Configure model
Model name
F1155-6 PC 3x400
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.15 kW

2.78 kW

El input

0.67 kW

0.93 kW

COP

4.72

2.99

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

157 %

Prated

5.50 kW

5.50 kW

SCOP

5.48

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.40 kW

3.40 kW

COP Tj = -7°C

5.17

3.77

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.10 kW

2.10 kW

COP Tj = +2°C

5.91

4.51

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.40 kW

1.40 kW

COP Tj = +7°C

6.36

5.12

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

4.15

4.81

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.40 kW

5.50 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2481 kWh

3287 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

150 %

Prated

5.50 kW

5.50 kW

SCOP

5.20

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

4.37

3.06

Pdh Tj = +2°C

3.10 kW

3.00 kW

COP Tj = +2°C

5.24

3.97

Pdh Tj = +7°C

2.00 kW

2.00 kW

COP Tj = +7°C

5.92

4.63

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

5.95

4.86

Pdh Tj = Tbiv

5.40 kW

5.40 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2188 kWh

2875 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

3.82 kW

El input

0.66 kW

1.00 kW

COP

6.49

3.83

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

282 %

222 %

Prated

7.00 kW

7.00 kW

SCOP

7.25

5.75

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

4.30 kW

COP Tj = -7°C

7.00

5.39

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

7.83

6.21

Pdh Tj = +7°C

1.80 kW

1.80 kW

COP Tj = +7°C

8.14

6.85

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.70

6.64

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3005 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

214 %

Prated

7.00 kW

7.00 kW

SCOP

6.95

5.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.30 kW

COP Tj = -7°C

6.07

4.52

Pdh Tj = +2°C

3.90 kW

3.90 kW

COP Tj = +2°C

7.09

5.62

Pdh Tj = +7°C

2.50 kW

2.50 kW

COP Tj = +7°C

7.84

6.34

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.97

6.57

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.97

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2078 kWh

2611 kWh

F1255-6 1x230
Configure model
Model name
F1255-6 1x230
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.15 kW

2.78 kW

El input

0.67 kW

0.93 kW

COP

4.72

2.99

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

157 %

Prated

5.50 kW

5.50 kW

SCOP

5.48

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.40 kW

3.40 kW

COP Tj = -7°C

5.17

3.77

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.10 kW

2.10 kW

COP Tj = +2°C

5.91

4.51

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.40 kW

1.40 kW

COP Tj = +7°C

6.36

5.12

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

4.15

4.81

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.40 kW

5.50 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2481 kWh

3287 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

150 %

Prated

5.50 kW

5.50 kW

SCOP

5.20

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

4.37

3.06

Pdh Tj = +2°C

3.10 kW

3.00 kW

COP Tj = +2°C

5.24

3.97

Pdh Tj = +7°C

2.00 kW

2.00 kW

COP Tj = +7°C

5.92

4.63

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

5.95

4.86

Pdh Tj = Tbiv

5.40 kW

5.40 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2188 kWh

2875 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.55

Heating up time

02:23 h:min

Standby power input

50.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

245 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.55

Heating up time

02:23 h:min

Standby power input

50.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

245 l

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

3.82 kW

El input

0.66 kW

1.00 kW

COP

6.49

3.83

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

282 %

222 %

Prated

7.00 kW

7.00 kW

SCOP

7.25

5.75

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

4.30 kW

COP Tj = -7°C

7.00

5.39

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

7.83

6.21

Pdh Tj = +7°C

1.80 kW

1.80 kW

COP Tj = +7°C

8.14

6.85

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.70

6.64

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3005 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

214 %

Prated

7.00 kW

7.00 kW

SCOP

6.95

5.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.30 kW

COP Tj = -7°C

6.07

4.52

Pdh Tj = +2°C

3.90 kW

3.90 kW

COP Tj = +2°C

7.09

5.62

Pdh Tj = +7°C

2.50 kW

2.50 kW

COP Tj = +7°C

7.84

6.34

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.97

6.57

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.97

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2078 kWh

2611 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.93

Heating up time

02:09 h:min

Standby power input

45.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

240 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.93

Heating up time

02:09 h:min

Standby power input

45.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

240 l

F1255-6 PC 1x230
Configure model
Model name
F1255-6 PC 1x230
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.15 kW

2.78 kW

El input

0.67 kW

0.93 kW

COP

4.72

2.99

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

157 %

Prated

5.50 kW

5.50 kW

SCOP

5.48

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.40 kW

3.40 kW

COP Tj = -7°C

5.17

3.77

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.10 kW

2.10 kW

COP Tj = +2°C

5.91

4.51

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.40 kW

1.40 kW

COP Tj = +7°C

6.36

5.12

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

4.15

4.81

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.40 kW

5.50 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2481 kWh

3287 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

150 %

Prated

5.50 kW

5.50 kW

SCOP

5.20

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

4.37

3.06

Pdh Tj = +2°C

3.10 kW

3.00 kW

COP Tj = +2°C

5.24

3.97

Pdh Tj = +7°C

2.00 kW

2.00 kW

COP Tj = +7°C

5.92

4.63

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

5.95

4.86

Pdh Tj = Tbiv

5.40 kW

5.40 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2188 kWh

2875 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.55

Heating up time

02:23 h:min

Standby power input

61.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

245 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.55

Heating up time

02:23 h:min

Standby power input

61.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

245 l

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

3.82 kW

El input

0.66 kW

1.00 kW

COP

6.49

3.83

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

282 %

222 %

Prated

7.00 kW

7.00 kW

SCOP

7.25

5.75

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

4.30 kW

COP Tj = -7°C

7.00

5.39

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

7.83

6.21

Pdh Tj = +7°C

1.80 kW

1.80 kW

COP Tj = +7°C

8.14

6.85

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.70

6.64

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3005 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

214 %

Prated

7.00 kW

7.00 kW

SCOP

6.95

5.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.30 kW

COP Tj = -7°C

6.07

4.52

Pdh Tj = +2°C

3.90 kW

3.90 kW

COP Tj = +2°C

7.09

5.62

Pdh Tj = +7°C

2.50 kW

2.50 kW

COP Tj = +7°C

7.84

6.34

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.97

6.57

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.97

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2078 kWh

2611 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.93

Heating up time

02:09 h:min

Standby power input

55.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

240 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.93

Heating up time

02:09 h:min

Standby power input

55.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

240 l

F1255-6 3x400
Configure model
Model name
F1255-6 3x400
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.15 kW

2.78 kW

El input

0.67 kW

0.93 kW

COP

4.72

2.99

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

157 %

Prated

5.50 kW

5.50 kW

SCOP

5.48

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.40 kW

3.40 kW

COP Tj = -7°C

5.17

3.77

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.10 kW

2.10 kW

COP Tj = +2°C

5.91

4.51

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.40 kW

1.40 kW

COP Tj = +7°C

6.36

5.12

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

4.15

4.81

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.40 kW

5.50 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2481 kWh

3287 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

150 %

Prated

5.50 kW

5.50 kW

SCOP

5.20

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

4.37

3.06

Pdh Tj = +2°C

3.10 kW

3.00 kW

COP Tj = +2°C

5.24

3.97

Pdh Tj = +7°C

2.00 kW

2.00 kW

COP Tj = +7°C

5.92

4.63

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

5.95

4.86

Pdh Tj = Tbiv

5.40 kW

5.40 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2188 kWh

2875 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.55

Heating up time

02:23 h:min

Standby power input

50.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

245 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.55

Heating up time

02:23 h:min

Standby power input

50.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

245 l

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

3.82 kW

El input

0.66 kW

1.00 kW

COP

6.49

3.83

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

282 %

222 %

Prated

7.00 kW

7.00 kW

SCOP

7.25

5.75

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

4.30 kW

COP Tj = -7°C

7.00

5.39

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

7.83

6.21

Pdh Tj = +7°C

1.80 kW

1.80 kW

COP Tj = +7°C

8.14

6.85

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.70

6.64

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3005 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

214 %

Prated

7.00 kW

7.00 kW

SCOP

6.95

5.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.30 kW

COP Tj = -7°C

6.07

4.52

Pdh Tj = +2°C

3.90 kW

3.90 kW

COP Tj = +2°C

7.09

5.62

Pdh Tj = +7°C

2.50 kW

2.50 kW

COP Tj = +7°C

7.84

6.34

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.97

6.57

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.97

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2078 kWh

2611 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.93

Heating up time

02:09 h:min

Standby power input

45.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

240 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.93

Heating up time

02:09 h:min

Standby power input

45.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

240 l

F1255-6 PC 3x400
Configure model
Model name
F1255-6 PC 3x400
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
No

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.15 kW

2.78 kW

El input

0.67 kW

0.93 kW

COP

4.72

2.99

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

157 %

Prated

5.50 kW

5.50 kW

SCOP

5.48

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.40 kW

3.40 kW

COP Tj = -7°C

5.17

3.77

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.10 kW

2.10 kW

COP Tj = +2°C

5.91

4.51

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.40 kW

1.40 kW

COP Tj = +7°C

6.36

5.12

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

4.15

4.81

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

5.40 kW

5.50 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2481 kWh

3287 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

150 %

Prated

5.50 kW

5.50 kW

SCOP

5.20

3.95

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.00 kW

5.00 kW

COP Tj = -7°C

4.37

3.06

Pdh Tj = +2°C

3.10 kW

3.00 kW

COP Tj = +2°C

5.24

3.97

Pdh Tj = +7°C

2.00 kW

2.00 kW

COP Tj = +7°C

5.92

4.63

Pdh Tj = 12°C

1.30 kW

1.20 kW

COP Tj = 12°C

5.95

4.86

Pdh Tj = Tbiv

5.40 kW

5.40 kW

COP Tj = Tbiv

4.15

2.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.15

2.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

10 W

7 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2188 kWh

2875 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.55

Heating up time

02:23 h:min

Standby power input

61.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

245 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.55

Heating up time

02:23 h:min

Standby power input

61.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

245 l

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.30 kW

3.82 kW

El input

0.66 kW

1.00 kW

COP

6.49

3.83

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

282 %

222 %

Prated

7.00 kW

7.00 kW

SCOP

7.25

5.75

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.30 kW

4.30 kW

COP Tj = -7°C

7.00

5.39

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

7.83

6.21

Pdh Tj = +7°C

1.80 kW

1.80 kW

COP Tj = +7°C

8.14

6.85

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.70

6.64

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.95

0.96

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2378 kWh

3005 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

42 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

270 %

214 %

Prated

7.00 kW

7.00 kW

SCOP

6.95

5.55

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.30 kW

6.30 kW

COP Tj = -7°C

6.07

4.52

Pdh Tj = +2°C

3.90 kW

3.90 kW

COP Tj = +2°C

7.09

5.62

Pdh Tj = +7°C

2.50 kW

2.50 kW

COP Tj = +7°C

7.84

6.34

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

7.97

6.57

Pdh Tj = Tbiv

7.00 kW

7.00 kW

COP Tj = Tbiv

5.79

4.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.00 kW

7.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.79

4.21

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.96

0.97

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

18 W

15 W

PSB

10 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2078 kWh

2611 kWh

Domestic Hot Water (DHW)

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.93

Heating up time

02:09 h:min

Standby power input

55.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

240 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

117 %

COP

2.93

Heating up time

02:09 h:min

Standby power input

55.0 W

Reference hot water temperature

49.0 °C

Mixed water at 40°C

240 l