Certificate holders

Subtype

TTF 04, TTF 04 cool, TTC 04, TTC 04 cool

Certificate Holder
tecalor GmbH
Fürstenbergerstr. 77
37603 Holzminden
Germany
Registration number
011-1W0038
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TTF 04, TTF 04 cool, TTC 04, TTC 04 cool
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

1,050 kg

Certification Date
01.11.2016
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 8

Models

TTF 04, all climates
Configure model
Model name
TTF 04, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

4.77 kW

El input

1.06 kW

COP

4.50

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Sound power level indoor

43 dB(A)

EN 14825

ηs

189 %

Prated

5.00 kW

SCOP

4.92

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

4.80 kW

COP Tj = -7°C

4.55

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

4.80 kW

COP Tj = +2°C

4.87

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.90 kW

COP Tj = +7°C

5.18

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.52

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2002 kWh

Warmer Climate

EN 14825

ηs

187 %

Prated

5.00 kW

SCOP

4.87

Tbiv

2 °C

TOL

0 °C

Pdh Tj = +2°C

4.80 kW

COP Tj = +2°C

4.50

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.80 kW

COP Tj = +7°C

4.80

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.29

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1310 kWh

Colder Climate

EN 14825

ηs

195 %

Prated

6.00 kW

SCOP

5.07

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

4.90 kW

COP Tj = -7°C

5.03

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

4.90 kW

COP Tj = +2°C

5.27

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.90 kW

COP Tj = +7°C

5.47

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.50

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.92

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.17 kW

Annual energy consumption Qhe

2888 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.80

COP Tj = -15°C (if TOL<-20°C)

4.92

Cdh Tj = -15 °C

0.90

TTF 04, average climates
Configure model
Model name
TTF 04, average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.77 kW

4.25 kW

El input

1.06 kW

1.56 kW

COP

4.50

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

128 %

Prated

5.00 kW

4.00 kW

SCOP

4.92

3.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.80 kW

4.30 kW

COP Tj = -7°C

4.55

2.85

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.80 kW

4.50 kW

COP Tj = +2°C

4.87

3.35

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.90 kW

4.60 kW

COP Tj = +7°C

5.18

3.73

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.90 kW

4.70 kW

COP Tj = 12°C

5.52

4.18

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.80 kW

4.30 kW

COP Tj = Tbiv

4.50

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.72

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

54 W

54 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2002 kWh

2583 kWh

TTF 04 cool, all climates
Configure model
Model name
TTF 04 cool, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

4.77 kW

El input

1.06 kW

COP

4.50

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Sound power level indoor

43 dB(A)

EN 14825

ηs

189 %

Prated

5.00 kW

SCOP

4.92

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

4.80 kW

COP Tj = -7°C

4.55

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

4.80 kW

COP Tj = +2°C

4.87

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.90 kW

COP Tj = +7°C

5.18

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.52

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2002 kWh

Warmer Climate

EN 14825

ηs

187 %

Prated

5.00 kW

SCOP

4.87

Tbiv

2 °C

TOL

0 °C

Pdh Tj = +2°C

4.80 kW

COP Tj = +2°C

4.50

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.80 kW

COP Tj = +7°C

4.80

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.29

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1310 kWh

Colder Climate

EN 14825

ηs

195 %

Prated

6.00 kW

SCOP

5.07

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

4.90 kW

COP Tj = -7°C

5.03

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

4.90 kW

COP Tj = +2°C

5.27

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.90 kW

COP Tj = +7°C

5.47

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.50

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.92

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.17 kW

Annual energy consumption Qhe

2888 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.80

COP Tj = -15°C (if TOL<-20°C)

4.92

Cdh Tj = -15 °C

0.90

TTF 04 cool, average climates
Configure model
Model name
TTF 04 cool, average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.77 kW

4.25 kW

El input

1.06 kW

1.56 kW

COP

4.50

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

128 %

Prated

5.00 kW

4.00 kW

SCOP

4.92

3.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.80 kW

4.30 kW

COP Tj = -7°C

4.55

2.85

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.80 kW

4.50 kW

COP Tj = +2°C

4.87

3.35

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.90 kW

4.60 kW

COP Tj = +7°C

5.18

3.73

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.90 kW

4.70 kW

COP Tj = 12°C

5.52

4.18

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.80 kW

4.30 kW

COP Tj = Tbiv

4.50

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.72

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

54 W

54 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2002 kWh

2583 kWh

TTC 04, all climates
Configure model
Model name
TTC 04, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

4.77 kW

El input

1.06 kW

COP

4.50

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Sound power level indoor

43 dB(A)

EN 14825

ηs

189 %

Prated

5.00 kW

SCOP

4.92

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

4.80 kW

COP Tj = -7°C

4.55

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

4.80 kW

COP Tj = +2°C

4.87

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.90 kW

COP Tj = +7°C

5.18

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.52

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2002 kWh

Warmer Climate

EN 14825

ηs

187 %

Prated

5.00 kW

SCOP

4.87

Tbiv

2 °C

TOL

0 °C

Pdh Tj = +2°C

4.80 kW

COP Tj = +2°C

4.50

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.80 kW

COP Tj = +7°C

4.80

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.29

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1310 kWh

Colder Climate

EN 14825

ηs

195 %

Prated

6.00 kW

SCOP

5.07

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

4.90 kW

COP Tj = -7°C

5.03

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

4.90 kW

COP Tj = +2°C

5.27

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.90 kW

COP Tj = +7°C

5.47

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.50

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.92

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.17 kW

Annual energy consumption Qhe

2888 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.80

COP Tj = -15°C (if TOL<-20°C)

4.92

Cdh Tj = -15 °C

0.90

TTC 04, average climates
Configure model
Model name
TTC 04, average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.77 kW

4.25 kW

El input

1.06 kW

1.56 kW

COP

4.50

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

128 %

Prated

5.00 kW

4.00 kW

SCOP

4.92

3.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.80 kW

4.30 kW

COP Tj = -7°C

4.55

2.85

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.80 kW

4.50 kW

COP Tj = +2°C

4.87

3.35

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.90 kW

4.60 kW

COP Tj = +7°C

5.18

3.73

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.90 kW

4.70 kW

COP Tj = 12°C

5.52

4.18

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.80 kW

4.30 kW

COP Tj = Tbiv

4.50

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.72

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

54 W

54 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2002 kWh

2583 kWh

TTC 04 cool, all climates
Configure model
Model name
TTC 04 cool, all climates
Application
Heating (low temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

4.77 kW

El input

1.06 kW

COP

4.50

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Sound power level indoor

43 dB(A)

EN 14825

ηs

189 %

Prated

5.00 kW

SCOP

4.92

Tbiv

-10 °C

TOL

-10 °C

Pdh Tj = -7°C

4.80 kW

COP Tj = -7°C

4.55

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

4.80 kW

COP Tj = +2°C

4.87

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.90 kW

COP Tj = +7°C

5.18

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.52

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

2002 kWh

Warmer Climate

EN 14825

ηs

187 %

Prated

5.00 kW

SCOP

4.87

Tbiv

2 °C

TOL

0 °C

Pdh Tj = +2°C

4.80 kW

COP Tj = +2°C

4.50

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.80 kW

COP Tj = +7°C

4.80

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.29

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.00 kW

Annual energy consumption Qhe

1310 kWh

Colder Climate

EN 14825

ηs

195 %

Prated

6.00 kW

SCOP

5.07

Tbiv

-15 °C

TOL

-22 °C

Pdh Tj = -7°C

4.90 kW

COP Tj = -7°C

5.03

Cdh Tj = -7 °C

0.90

Pdh Tj = +2°C

4.90 kW

COP Tj = +2°C

5.27

Cdh Tj = +2 °C

0.90

Pdh Tj = +7°C

4.90 kW

COP Tj = +7°C

5.47

Cdh Tj = +7 °C

0.90

Pdh Tj = 12°C

4.90 kW

COP Tj = 12°C

5.50

Cdh Tj = +12 °C

0.90

Pdh Tj = Tbiv

4.80 kW

COP Tj = Tbiv

4.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.92

WTOL

65 °C

Poff

0 W

PTO

54 W

PSB

9 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

1.17 kW

Annual energy consumption Qhe

2888 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.80

COP Tj = -15°C (if TOL<-20°C)

4.92

Cdh Tj = -15 °C

0.90

TTC 04 cool, average climates
Configure model
Model name
TTC 04 cool, average climates
Application
Heating (medium temp)
Units
Indoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.77 kW

4.25 kW

El input

1.06 kW

1.56 kW

COP

4.50

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

128 %

Prated

5.00 kW

4.00 kW

SCOP

4.92

3.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.80 kW

4.30 kW

COP Tj = -7°C

4.55

2.85

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.80 kW

4.50 kW

COP Tj = +2°C

4.87

3.35

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

4.90 kW

4.60 kW

COP Tj = +7°C

5.18

3.73

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.90 kW

4.70 kW

COP Tj = 12°C

5.52

4.18

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.80 kW

4.30 kW

COP Tj = Tbiv

4.50

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.80 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.72

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

54 W

54 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2002 kWh

2583 kWh