1,400 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.24 kW
4.78 kW
El input
1.10 kW
1.68 kW
COP
4.75
2.85
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
157 %
Prated
11.69 kW
10.60 kW
SCOP
5.68
4.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.34 kW
9.38 kW
COP Tj = -7°C
4.77
3.15
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
6.29 kW
5.71 kW
COP Tj = +2°C
5.82
4.20
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.05 kW
3.67 kW
COP Tj = +7°C
6.40
4.81
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.91 kW
2.91 kW
COP Tj = 12°C
5.97
4.66
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4249 kWh
5320 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
224 %
163 %
Prated
11.69 kW
10.60 kW
SCOP
5.80
4.29
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.07 kW
6.41 kW
COP Tj = -7°C
5.46
3.99
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.31 kW
3.90 kW
COP Tj = +2°C
6.39
4.77
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.77 kW
2.92 kW
COP Tj = +7°C
6.32
4.71
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.89 kW
2.92 kW
COP Tj = 12°C
5.78
4.74
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4963 kWh
6094 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.53
8.65
COP Tj = -15°C (if TOL<-20°C)
4.92
3.44
Cdh Tj = -15 °C
0.99
1.00
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.06 kW
6.26 kW
El input
1.08 kW
1.71 kW
COP
6.56
3.66
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
290 %
206 %
Prated
10.42 kW
11.60 kW
SCOP
7.45
5.36
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.22 kW
10.26 kW
COP Tj = -7°C
6.60
4.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
5.61 kW
6.25 kW
COP Tj = +2°C
7.78
5.49
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.88 kW
4.02 kW
COP Tj = +7°C
8.02
6.19
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.88 kW
3.74 kW
COP Tj = 12°C
8.04
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2890 kWh
4473 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
299 %
214 %
Prated
10.42 kW
11.60 kW
SCOP
7.68
5.56
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.31 kW
7.02 kW
COP Tj = -7°C
7.84
5.18
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
3.84 kW
4.27 kW
COP Tj = +2°C
7.93
6.12
Cdh Tj = +2 °C
0.96
0.98
Pdh Tj = +7°C
3.88 kW
3.75 kW
COP Tj = +7°C
8.07
6.35
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.89 kW
3.78 kW
COP Tj = 12°C
7.88
6.54
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3346 kWh
5142 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.50
9.46
COP Tj = -15°C (if TOL<-20°C)
7.09
4.46
Cdh Tj = -15 °C
0.99
0.99
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.24 kW
4.78 kW
El input
1.10 kW
1.68 kW
COP
4.75
2.85
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
157 %
Prated
11.69 kW
10.60 kW
SCOP
5.68
4.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.34 kW
9.38 kW
COP Tj = -7°C
4.77
3.15
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
6.29 kW
5.71 kW
COP Tj = +2°C
5.82
4.20
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.05 kW
3.67 kW
COP Tj = +7°C
6.40
4.81
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.91 kW
2.91 kW
COP Tj = 12°C
5.97
4.66
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4249 kWh
5320 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
224 %
163 %
Prated
11.69 kW
10.60 kW
SCOP
5.80
4.29
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.07 kW
6.41 kW
COP Tj = -7°C
5.46
3.99
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.31 kW
3.90 kW
COP Tj = +2°C
6.39
4.77
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.77 kW
2.92 kW
COP Tj = +7°C
6.32
4.71
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.89 kW
2.92 kW
COP Tj = 12°C
5.78
4.74
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4963 kWh
6094 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.53
8.65
COP Tj = -15°C (if TOL<-20°C)
4.92
3.44
Cdh Tj = -15 °C
0.99
1.00
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.06 kW
6.26 kW
El input
1.08 kW
1.71 kW
COP
6.56
3.66
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
290 %
206 %
Prated
10.42 kW
11.60 kW
SCOP
7.45
5.36
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.22 kW
10.26 kW
COP Tj = -7°C
6.60
4.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
5.61 kW
6.25 kW
COP Tj = +2°C
7.78
5.49
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.88 kW
4.02 kW
COP Tj = +7°C
8.02
6.19
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.88 kW
3.74 kW
COP Tj = 12°C
8.04
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2890 kWh
4473 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
299 %
214 %
Prated
10.42 kW
11.60 kW
SCOP
7.68
5.56
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.31 kW
7.02 kW
COP Tj = -7°C
7.84
5.18
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
3.84 kW
4.27 kW
COP Tj = +2°C
7.93
6.12
Cdh Tj = +2 °C
0.96
0.98
Pdh Tj = +7°C
3.88 kW
3.75 kW
COP Tj = +7°C
8.07
6.35
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.89 kW
3.78 kW
COP Tj = 12°C
7.88
6.54
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3346 kWh
5142 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.50
9.46
COP Tj = -15°C (if TOL<-20°C)
7.09
4.46
Cdh Tj = -15 °C
0.99
0.99
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.24 kW
4.78 kW
El input
1.10 kW
1.68 kW
COP
4.75
2.85
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
157 %
Prated
11.69 kW
10.60 kW
SCOP
5.68
4.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.34 kW
9.38 kW
COP Tj = -7°C
4.77
3.15
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
6.29 kW
5.71 kW
COP Tj = +2°C
5.82
4.20
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.05 kW
3.67 kW
COP Tj = +7°C
6.40
4.81
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.91 kW
2.91 kW
COP Tj = 12°C
5.97
4.66
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4249 kWh
5320 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
224 %
163 %
Prated
11.69 kW
10.60 kW
SCOP
5.80
4.29
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.07 kW
6.41 kW
COP Tj = -7°C
5.46
3.99
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.31 kW
3.90 kW
COP Tj = +2°C
6.39
4.77
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.77 kW
2.92 kW
COP Tj = +7°C
6.32
4.71
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.89 kW
2.92 kW
COP Tj = 12°C
5.78
4.74
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4963 kWh
6094 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.53
8.65
COP Tj = -15°C (if TOL<-20°C)
4.92
3.44
Cdh Tj = -15 °C
0.99
1.00
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.06 kW
6.26 kW
El input
1.08 kW
1.71 kW
COP
6.56
3.66
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
290 %
206 %
Prated
10.42 kW
11.60 kW
SCOP
7.45
5.36
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.22 kW
10.26 kW
COP Tj = -7°C
6.60
4.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
5.61 kW
6.25 kW
COP Tj = +2°C
7.78
5.49
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.88 kW
4.02 kW
COP Tj = +7°C
8.02
6.19
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.88 kW
3.74 kW
COP Tj = 12°C
8.04
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2890 kWh
4473 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
299 %
214 %
Prated
10.42 kW
11.60 kW
SCOP
7.68
5.56
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.31 kW
7.02 kW
COP Tj = -7°C
7.84
5.18
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
3.84 kW
4.27 kW
COP Tj = +2°C
7.93
6.12
Cdh Tj = +2 °C
0.96
0.98
Pdh Tj = +7°C
3.88 kW
3.75 kW
COP Tj = +7°C
8.07
6.35
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.89 kW
3.78 kW
COP Tj = 12°C
7.88
6.54
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3346 kWh
5142 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.50
9.46
COP Tj = -15°C (if TOL<-20°C)
7.09
4.46
Cdh Tj = -15 °C
0.99
0.99
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.24 kW
4.78 kW
El input
1.10 kW
1.68 kW
COP
4.75
2.85
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
157 %
Prated
11.69 kW
10.60 kW
SCOP
5.68
4.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.34 kW
9.38 kW
COP Tj = -7°C
4.77
3.15
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
6.29 kW
5.71 kW
COP Tj = +2°C
5.82
4.20
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.05 kW
3.67 kW
COP Tj = +7°C
6.40
4.81
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.91 kW
2.91 kW
COP Tj = 12°C
5.97
4.66
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4249 kWh
5320 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
224 %
163 %
Prated
11.69 kW
10.60 kW
SCOP
5.80
4.29
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.07 kW
6.41 kW
COP Tj = -7°C
5.46
3.99
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.31 kW
3.90 kW
COP Tj = +2°C
6.39
4.77
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.77 kW
2.92 kW
COP Tj = +7°C
6.32
4.71
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.89 kW
2.92 kW
COP Tj = 12°C
5.78
4.74
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4963 kWh
6094 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.53
8.65
COP Tj = -15°C (if TOL<-20°C)
4.92
3.44
Cdh Tj = -15 °C
0.99
1.00
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.06 kW
6.26 kW
El input
1.08 kW
1.71 kW
COP
6.56
3.66
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
36 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
290 %
206 %
Prated
10.42 kW
11.60 kW
SCOP
7.45
5.36
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.22 kW
10.26 kW
COP Tj = -7°C
6.60
4.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
5.61 kW
6.25 kW
COP Tj = +2°C
7.78
5.49
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.88 kW
4.02 kW
COP Tj = +7°C
8.02
6.19
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.88 kW
3.74 kW
COP Tj = 12°C
8.04
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2890 kWh
4473 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
299 %
214 %
Prated
10.42 kW
11.60 kW
SCOP
7.68
5.56
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.31 kW
7.02 kW
COP Tj = -7°C
7.84
5.18
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
3.84 kW
4.27 kW
COP Tj = +2°C
7.93
6.12
Cdh Tj = +2 °C
0.96
0.98
Pdh Tj = +7°C
3.88 kW
3.75 kW
COP Tj = +7°C
8.07
6.35
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.89 kW
3.78 kW
COP Tj = 12°C
7.88
6.54
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3346 kWh
5142 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.50
9.46
COP Tj = -15°C (if TOL<-20°C)
7.09
4.46
Cdh Tj = -15 °C
0.99
0.99
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.24 kW
4.78 kW
El input
1.10 kW
1.68 kW
COP
4.75
2.85
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
157 %
Prated
11.69 kW
10.60 kW
SCOP
5.68
4.12
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.34 kW
9.38 kW
COP Tj = -7°C
4.77
3.15
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
6.29 kW
5.71 kW
COP Tj = +2°C
5.82
4.20
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.05 kW
3.67 kW
COP Tj = +7°C
6.40
4.81
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.91 kW
2.91 kW
COP Tj = 12°C
5.97
4.66
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4249 kWh
5320 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
224 %
163 %
Prated
11.69 kW
10.60 kW
SCOP
5.80
4.29
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.07 kW
6.41 kW
COP Tj = -7°C
5.46
3.99
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
4.31 kW
3.90 kW
COP Tj = +2°C
6.39
4.77
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.77 kW
2.92 kW
COP Tj = +7°C
6.32
4.71
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.89 kW
2.92 kW
COP Tj = 12°C
5.78
4.74
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
11.69 kW
10.60 kW
COP Tj = Tbiv
4.39
2.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.69 kW
10.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.39
2.88
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4963 kWh
6094 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.53
8.65
COP Tj = -15°C (if TOL<-20°C)
4.92
3.44
Cdh Tj = -15 °C
0.99
1.00
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.06 kW
6.26 kW
El input
1.08 kW
1.71 kW
COP
6.56
3.66
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
290 %
206 %
Prated
10.42 kW
11.60 kW
SCOP
7.45
5.36
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.22 kW
10.26 kW
COP Tj = -7°C
6.60
4.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
5.61 kW
6.25 kW
COP Tj = +2°C
7.78
5.49
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
3.88 kW
4.02 kW
COP Tj = +7°C
8.02
6.19
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.88 kW
3.74 kW
COP Tj = 12°C
8.04
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2890 kWh
4473 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
299 %
214 %
Prated
10.42 kW
11.60 kW
SCOP
7.68
5.56
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
6.31 kW
7.02 kW
COP Tj = -7°C
7.84
5.18
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
3.84 kW
4.27 kW
COP Tj = +2°C
7.93
6.12
Cdh Tj = +2 °C
0.96
0.98
Pdh Tj = +7°C
3.88 kW
3.75 kW
COP Tj = +7°C
8.07
6.35
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.89 kW
3.78 kW
COP Tj = 12°C
7.88
6.54
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
10.42 kW
11.60 kW
COP Tj = Tbiv
6.34
3.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.42 kW
11.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.34
3.73
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3346 kWh
5142 kWh
Pdh Tj = -15°C (if TOL<-20°C)
8.50
9.46
COP Tj = -15°C (if TOL<-20°C)
7.09
4.46
Cdh Tj = -15 °C
0.99
0.99