Thermia Calibra 12

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-SC0356-19
Certification Body
RISE CERT
Subtype title
Thermia Calibra 12
Driving energy
n/a
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

1,400 kg

Certification Date
04.10.2019
Testing basis
EN 14511:2018; EN 14825:2016; EN 12102:2017
Generate PDF Export model CSV Download certificate
  • Number of models 5

Models

Thermia Calibra 12 400V
Configure model
Model name
Thermia Calibra 12 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.24 kW

4.78 kW

El input

1.10 kW

1.68 kW

COP

4.75

2.85

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

157 %

Prated

11.69 kW

10.60 kW

SCOP

5.68

4.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.34 kW

9.38 kW

COP Tj = -7°C

4.77

3.15

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

6.29 kW

5.71 kW

COP Tj = +2°C

5.82

4.20

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

4.05 kW

3.67 kW

COP Tj = +7°C

6.40

4.81

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

2.91 kW

2.91 kW

COP Tj = 12°C

5.97

4.66

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4249 kWh

5320 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

224 %

163 %

Prated

11.69 kW

10.60 kW

SCOP

5.80

4.29

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.07 kW

6.41 kW

COP Tj = -7°C

5.46

3.99

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.31 kW

3.90 kW

COP Tj = +2°C

6.39

4.77

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.77 kW

2.92 kW

COP Tj = +7°C

6.32

4.71

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.89 kW

2.92 kW

COP Tj = 12°C

5.78

4.74

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4963 kWh

6094 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.53

8.65

COP Tj = -15°C (if TOL<-20°C)

4.92

3.44

Cdh Tj = -15 °C

0.99

1.00

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.06 kW

6.26 kW

El input

1.08 kW

1.71 kW

COP

6.56

3.66

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

290 %

206 %

Prated

10.42 kW

11.60 kW

SCOP

7.45

5.36

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.22 kW

10.26 kW

COP Tj = -7°C

6.60

4.09

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.61 kW

6.25 kW

COP Tj = +2°C

7.78

5.49

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.88 kW

4.02 kW

COP Tj = +7°C

8.02

6.19

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.88 kW

3.74 kW

COP Tj = 12°C

8.04

6.34

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2890 kWh

4473 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

299 %

214 %

Prated

10.42 kW

11.60 kW

SCOP

7.68

5.56

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.31 kW

7.02 kW

COP Tj = -7°C

7.84

5.18

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

3.84 kW

4.27 kW

COP Tj = +2°C

7.93

6.12

Cdh Tj = +2 °C

0.96

0.98

Pdh Tj = +7°C

3.88 kW

3.75 kW

COP Tj = +7°C

8.07

6.35

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.89 kW

3.78 kW

COP Tj = 12°C

7.88

6.54

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3346 kWh

5142 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.50

9.46

COP Tj = -15°C (if TOL<-20°C)

7.09

4.46

Cdh Tj = -15 °C

0.99

0.99

Thermia Calibra 12 Duo 400V
Configure model
Model name
Thermia Calibra 12 Duo 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.24 kW

4.78 kW

El input

1.10 kW

1.68 kW

COP

4.75

2.85

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

157 %

Prated

11.69 kW

10.60 kW

SCOP

5.68

4.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.34 kW

9.38 kW

COP Tj = -7°C

4.77

3.15

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

6.29 kW

5.71 kW

COP Tj = +2°C

5.82

4.20

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

4.05 kW

3.67 kW

COP Tj = +7°C

6.40

4.81

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

2.91 kW

2.91 kW

COP Tj = 12°C

5.97

4.66

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4249 kWh

5320 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

224 %

163 %

Prated

11.69 kW

10.60 kW

SCOP

5.80

4.29

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.07 kW

6.41 kW

COP Tj = -7°C

5.46

3.99

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.31 kW

3.90 kW

COP Tj = +2°C

6.39

4.77

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.77 kW

2.92 kW

COP Tj = +7°C

6.32

4.71

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.89 kW

2.92 kW

COP Tj = 12°C

5.78

4.74

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4963 kWh

6094 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.53

8.65

COP Tj = -15°C (if TOL<-20°C)

4.92

3.44

Cdh Tj = -15 °C

0.99

1.00

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.06 kW

6.26 kW

El input

1.08 kW

1.71 kW

COP

6.56

3.66

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

290 %

206 %

Prated

10.42 kW

11.60 kW

SCOP

7.45

5.36

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.22 kW

10.26 kW

COP Tj = -7°C

6.60

4.09

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.61 kW

6.25 kW

COP Tj = +2°C

7.78

5.49

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.88 kW

4.02 kW

COP Tj = +7°C

8.02

6.19

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.88 kW

3.74 kW

COP Tj = 12°C

8.04

6.34

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2890 kWh

4473 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

299 %

214 %

Prated

10.42 kW

11.60 kW

SCOP

7.68

5.56

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.31 kW

7.02 kW

COP Tj = -7°C

7.84

5.18

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

3.84 kW

4.27 kW

COP Tj = +2°C

7.93

6.12

Cdh Tj = +2 °C

0.96

0.98

Pdh Tj = +7°C

3.88 kW

3.75 kW

COP Tj = +7°C

8.07

6.35

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.89 kW

3.78 kW

COP Tj = 12°C

7.88

6.54

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3346 kWh

5142 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.50

9.46

COP Tj = -15°C (if TOL<-20°C)

7.09

4.46

Cdh Tj = -15 °C

0.99

0.99

Thermia Calibra 12 230V
Configure model
Model name
Thermia Calibra 12 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.24 kW

4.78 kW

El input

1.10 kW

1.68 kW

COP

4.75

2.85

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

157 %

Prated

11.69 kW

10.60 kW

SCOP

5.68

4.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.34 kW

9.38 kW

COP Tj = -7°C

4.77

3.15

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

6.29 kW

5.71 kW

COP Tj = +2°C

5.82

4.20

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

4.05 kW

3.67 kW

COP Tj = +7°C

6.40

4.81

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

2.91 kW

2.91 kW

COP Tj = 12°C

5.97

4.66

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4249 kWh

5320 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

224 %

163 %

Prated

11.69 kW

10.60 kW

SCOP

5.80

4.29

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.07 kW

6.41 kW

COP Tj = -7°C

5.46

3.99

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.31 kW

3.90 kW

COP Tj = +2°C

6.39

4.77

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.77 kW

2.92 kW

COP Tj = +7°C

6.32

4.71

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.89 kW

2.92 kW

COP Tj = 12°C

5.78

4.74

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4963 kWh

6094 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.53

8.65

COP Tj = -15°C (if TOL<-20°C)

4.92

3.44

Cdh Tj = -15 °C

0.99

1.00

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.06 kW

6.26 kW

El input

1.08 kW

1.71 kW

COP

6.56

3.66

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

290 %

206 %

Prated

10.42 kW

11.60 kW

SCOP

7.45

5.36

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.22 kW

10.26 kW

COP Tj = -7°C

6.60

4.09

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.61 kW

6.25 kW

COP Tj = +2°C

7.78

5.49

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.88 kW

4.02 kW

COP Tj = +7°C

8.02

6.19

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.88 kW

3.74 kW

COP Tj = 12°C

8.04

6.34

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2890 kWh

4473 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

299 %

214 %

Prated

10.42 kW

11.60 kW

SCOP

7.68

5.56

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.31 kW

7.02 kW

COP Tj = -7°C

7.84

5.18

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

3.84 kW

4.27 kW

COP Tj = +2°C

7.93

6.12

Cdh Tj = +2 °C

0.96

0.98

Pdh Tj = +7°C

3.88 kW

3.75 kW

COP Tj = +7°C

8.07

6.35

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.89 kW

3.78 kW

COP Tj = 12°C

7.88

6.54

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3346 kWh

5142 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.50

9.46

COP Tj = -15°C (if TOL<-20°C)

7.09

4.46

Cdh Tj = -15 °C

0.99

0.99

Thermia Calibra 12 Duo 230V
Configure model
Model name
Thermia Calibra 12 Duo 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.24 kW

4.78 kW

El input

1.10 kW

1.68 kW

COP

4.75

2.85

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

157 %

Prated

11.69 kW

10.60 kW

SCOP

5.68

4.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.34 kW

9.38 kW

COP Tj = -7°C

4.77

3.15

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

6.29 kW

5.71 kW

COP Tj = +2°C

5.82

4.20

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

4.05 kW

3.67 kW

COP Tj = +7°C

6.40

4.81

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

2.91 kW

2.91 kW

COP Tj = 12°C

5.97

4.66

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4249 kWh

5320 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

224 %

163 %

Prated

11.69 kW

10.60 kW

SCOP

5.80

4.29

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.07 kW

6.41 kW

COP Tj = -7°C

5.46

3.99

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.31 kW

3.90 kW

COP Tj = +2°C

6.39

4.77

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.77 kW

2.92 kW

COP Tj = +7°C

6.32

4.71

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.89 kW

2.92 kW

COP Tj = 12°C

5.78

4.74

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4963 kWh

6094 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.53

8.65

COP Tj = -15°C (if TOL<-20°C)

4.92

3.44

Cdh Tj = -15 °C

0.99

1.00

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.06 kW

6.26 kW

El input

1.08 kW

1.71 kW

COP

6.56

3.66

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

290 %

206 %

Prated

10.42 kW

11.60 kW

SCOP

7.45

5.36

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.22 kW

10.26 kW

COP Tj = -7°C

6.60

4.09

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.61 kW

6.25 kW

COP Tj = +2°C

7.78

5.49

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.88 kW

4.02 kW

COP Tj = +7°C

8.02

6.19

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.88 kW

3.74 kW

COP Tj = 12°C

8.04

6.34

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2890 kWh

4473 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

299 %

214 %

Prated

10.42 kW

11.60 kW

SCOP

7.68

5.56

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.31 kW

7.02 kW

COP Tj = -7°C

7.84

5.18

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

3.84 kW

4.27 kW

COP Tj = +2°C

7.93

6.12

Cdh Tj = +2 °C

0.96

0.98

Pdh Tj = +7°C

3.88 kW

3.75 kW

COP Tj = +7°C

8.07

6.35

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.89 kW

3.78 kW

COP Tj = 12°C

7.88

6.54

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3346 kWh

5142 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.50

9.46

COP Tj = -15°C (if TOL<-20°C)

7.09

4.46

Cdh Tj = -15 °C

0.99

0.99

Thermia Calibra 12 400V (White)
Configure model
Model name
Thermia Calibra 12 400V (White)
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.24 kW

4.78 kW

El input

1.10 kW

1.68 kW

COP

4.75

2.85

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

157 %

Prated

11.69 kW

10.60 kW

SCOP

5.68

4.12

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.34 kW

9.38 kW

COP Tj = -7°C

4.77

3.15

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

6.29 kW

5.71 kW

COP Tj = +2°C

5.82

4.20

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

4.05 kW

3.67 kW

COP Tj = +7°C

6.40

4.81

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

2.91 kW

2.91 kW

COP Tj = 12°C

5.97

4.66

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4249 kWh

5320 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

224 %

163 %

Prated

11.69 kW

10.60 kW

SCOP

5.80

4.29

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.07 kW

6.41 kW

COP Tj = -7°C

5.46

3.99

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.31 kW

3.90 kW

COP Tj = +2°C

6.39

4.77

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

2.77 kW

2.92 kW

COP Tj = +7°C

6.32

4.71

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

2.89 kW

2.92 kW

COP Tj = 12°C

5.78

4.74

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

11.69 kW

10.60 kW

COP Tj = Tbiv

4.39

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.69 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.88

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4963 kWh

6094 kWh

Pdh Tj = -15°C (if TOL<-20°C)

9.53

8.65

COP Tj = -15°C (if TOL<-20°C)

4.92

3.44

Cdh Tj = -15 °C

0.99

1.00

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.06 kW

6.26 kW

El input

1.08 kW

1.71 kW

COP

6.56

3.66

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

290 %

206 %

Prated

10.42 kW

11.60 kW

SCOP

7.45

5.36

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

9.22 kW

10.26 kW

COP Tj = -7°C

6.60

4.09

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

5.61 kW

6.25 kW

COP Tj = +2°C

7.78

5.49

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.88 kW

4.02 kW

COP Tj = +7°C

8.02

6.19

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.88 kW

3.74 kW

COP Tj = 12°C

8.04

6.34

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2890 kWh

4473 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

299 %

214 %

Prated

10.42 kW

11.60 kW

SCOP

7.68

5.56

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.31 kW

7.02 kW

COP Tj = -7°C

7.84

5.18

Cdh Tj = -7 °C

0.98

0.99

Pdh Tj = +2°C

3.84 kW

4.27 kW

COP Tj = +2°C

7.93

6.12

Cdh Tj = +2 °C

0.96

0.98

Pdh Tj = +7°C

3.88 kW

3.75 kW

COP Tj = +7°C

8.07

6.35

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.89 kW

3.78 kW

COP Tj = 12°C

7.88

6.54

Cdh Tj = +12 °C

0.96

0.97

Pdh Tj = Tbiv

10.42 kW

11.60 kW

COP Tj = Tbiv

6.34

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.42 kW

11.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.34

3.73

WTOL

65 °C

65 °C

Poff

15 W

15 W

PTO

18 W

18 W

PSB

18 W

18 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3346 kWh

5142 kWh

Pdh Tj = -15°C (if TOL<-20°C)

8.50

9.46

COP Tj = -15°C (if TOL<-20°C)

7.09

4.46

Cdh Tj = -15 °C

0.99