Certificate holders

Subtype

Daikin Altherma LT split integrated solar 16 kW 3ph / ROTEX HPSU Compact H (BIV) 16 kW 3ph

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Reg. No.
011-1W0095
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Daikin Altherma LT split integrated solar 16 kW 3ph / ROTEX HPSU Compact H (BIV) 16 kW 3ph
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410a
Mass Of Refrigerant

3,400 kg

Certification Date
30.03.2017
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 4

Models

ERLQ016C*W1 / EHSH16P50B
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.34 kW

14.32 kW

El input

3.74 kW

5.64 kW

COP

4.10

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

125 %

Prated

16.00 kW

14.00 kW

SCOP

3.80

3.27

Tbiv

-4 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.40 kW

12.60 kW

COP Tj = -7°C

2.33

1.85

Cdh

1.00

1.00

Pdh Tj = +2°C

8.62 kW

7.80 kW

COP Tj = +2°C

3.74

3.19

Cdh

1.00

1.00

Pdh Tj = +7°C

5.74 kW

4.90 kW

COP Tj = +7°C

6.77

4.47

Cdh

0.94

1.00

Pdh Tj = 12°C

6.50 kW

5.40 kW

COP Tj = 12°C

8.97

6.52

Cdh

0.92

0.90

Pdh Tj = Tbiv

12.10 kW

12.60 kW

COP Tj = Tbiv

2.56

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.70 kW

11.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.05

1.57

WTOL

35 °C

55 °C

Poff

50 W

50 W

PTO

105 W

105 W

PSB

50 W

50 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

9.00 kW

9.00 kW

Annual energy consumption Qhe

8270 kWh

8978 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

83 %

COP

2.11

Heating up time

1:20 h:min

Standby power input

67.4 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

237 l

RRLQ016C*W1 / HPSU Compact 516 H
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.34 kW

14.32 kW

El input

3.74 kW

5.64 kW

COP

4.10

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

125 %

Prated

16.00 kW

14.00 kW

SCOP

3.80

3.27

Tbiv

-4 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.40 kW

12.60 kW

COP Tj = -7°C

2.33

1.85

Cdh

1.00

1.00

Pdh Tj = +2°C

8.62 kW

7.80 kW

COP Tj = +2°C

3.74

3.19

Cdh

1.00

1.00

Pdh Tj = +7°C

5.74 kW

4.90 kW

COP Tj = +7°C

6.77

4.47

Cdh

0.94

1.00

Pdh Tj = 12°C

6.50 kW

5.40 kW

COP Tj = 12°C

8.97

6.52

Cdh

0.92

0.90

Pdh Tj = Tbiv

12.10 kW

12.60 kW

COP Tj = Tbiv

2.56

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.70 kW

11.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.05

1.57

WTOL

35 °C

55 °C

Poff

50 W

50 W

PTO

105 W

105 W

PSB

50 W

50 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

9.00 kW

9.00 kW

Annual energy consumption Qhe

8270 kWh

8978 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

83 %

COP

2.11

Heating up time

1:20 h:min

Standby power input

67.4 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

237 l

ERLQ016C*W1 / EHSHB16P50B
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.34 kW

14.32 kW

El input

3.74 kW

5.64 kW

COP

4.10

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

125 %

Prated

16.00 kW

14.00 kW

SCOP

3.80

3.27

Tbiv

-4 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.40 kW

12.60 kW

COP Tj = -7°C

2.33

1.85

Cdh

1.00

1.00

Pdh Tj = +2°C

8.62 kW

7.80 kW

COP Tj = +2°C

3.74

3.19

Cdh

1.00

1.00

Pdh Tj = +7°C

5.74 kW

4.90 kW

COP Tj = +7°C

6.77

4.47

Cdh

0.94

1.00

Pdh Tj = 12°C

6.50 kW

5.40 kW

COP Tj = 12°C

8.97

6.52

Cdh

0.92

0.90

Pdh Tj = Tbiv

12.10 kW

12.60 kW

COP Tj = Tbiv

2.56

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.70 kW

11.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.05

1.57

WTOL

35 °C

55 °C

Poff

50 W

50 W

PTO

105 W

105 W

PSB

50 W

50 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

9.00 kW

9.00 kW

Annual energy consumption Qhe

8270 kWh

8978 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

84 %

COP

2.14

Heating up time

1:20 h:min

Standby power input

66.1 W

Reference hot water temperature

45.0 °C

Mixed water at 40°C

211 l

RRLQ016C*W1 / HPSU Compact 516 H Biv
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.34 kW

14.32 kW

El input

3.74 kW

5.64 kW

COP

4.10

2.51

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

125 %

Prated

16.00 kW

14.00 kW

SCOP

3.80

3.27

Tbiv

-4 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.40 kW

12.60 kW

COP Tj = -7°C

2.33

1.85

Cdh

1.00

1.00

Pdh Tj = +2°C

8.62 kW

7.80 kW

COP Tj = +2°C

3.74

3.19

Cdh

1.00

1.00

Pdh Tj = +7°C

5.74 kW

4.90 kW

COP Tj = +7°C

6.77

4.47

Cdh

0.94

1.00

Pdh Tj = 12°C

6.50 kW

5.40 kW

COP Tj = 12°C

8.97

6.52

Cdh

0.92

0.90

Pdh Tj = Tbiv

12.10 kW

12.60 kW

COP Tj = Tbiv

2.56

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.70 kW

11.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.05

1.57

WTOL

35 °C

55 °C

Poff

50 W

50 W

PTO

105 W

105 W

PSB

50 W

50 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

electrical

electrical

Supplementary Heater: PSUP

9.00 kW

9.00 kW

Annual energy consumption Qhe

8270 kWh

8978 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

84 %

COP

2.14

Heating up time

1:20 h:min

Standby power input

66.1 W

Reference hot water temperature

45.0 °C

Mixed water at 40°C

211 l