1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.20 kW
8.80 kW
El input
2.34 kW
3.27 kW
COP
4.35
2.69
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
202 %
144 %
Prated
10.40 kW
8.72 kW
SCOP
5.26
3.79
Tbiv
-9 °C
-9 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.99 kW
7.65 kW
COP Tj = -7°C
4.45
2.93
Cdh
1.00
1.00
Pdh Tj = +2°C
5.64 kW
4.62 kW
COP Tj = +2°C
5.40
3.82
Cdh
1.00
1.00
Pdh Tj = +7°C
3.69 kW
2.94 kW
COP Tj = +7°C
5.89
4.39
Cdh
1.00
1.00
Pdh Tj = 12°C
2.57 kW
2.51 kW
COP Tj = 12°C
6.02
5.06
Cdh
0.92
0.90
Pdh Tj = Tbiv
10.00 kW
8.35 kW
COP Tj = Tbiv
4.21
2.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.99 kW
8.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.20
2.82
WTOL
35 °C
55 °C
Poff
20 W
20 W
PTO
37 W
37 W
PSB
20 W
20 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electrical
Electrical
Supplementary Heater: PSUP
9.00 kW
9.00 kW
Annual energy consumption Qhe
4017 kWh
4676 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Standby power input
42.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
199 l
COP
2.28
Efficiency ηDHW
93 %
Heating up time
1:25 h:min