Ecodan Zubadan 14-300D
Heat Pump Type: Outdoor Air/Water
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.00 kW
14.00 kW
El input
3.32 kW
5.62 kW
COP
4.22
2.49
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
70 dB(A)
70 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
128 %
Prated
17.00 kW
15.80 kW
SCOP
4.21
3.27
Tbiv
-7 °C
-7 °C
TOL
-28 °C
-28 °C
Pdh Tj = -7°C
15.00 kW
14.00 kW
COP Tj = -7°C
2.59
1.84
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
9.10 kW
8.50 kW
COP Tj = +2°C
4.03
3.10
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
5.90 kW
5.50 kW
COP Tj = +7°C
5.71
4.67
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
7.30 kW
7.00 kW
COP Tj = 12°C
7.47
6.62
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
15.00 kW
14.00 kW
COP Tj = Tbiv
2.59
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.10 kW
13.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.42
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.90 kW
1.90 kW
Annual energy consumption Qhe
8344 kWh
9973 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
118 %
COP
2.84
Heating up time
02:12 h:min
Standby power input
43.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
417 l