Ecodan Power Inverter 8-200D AA
Heat Pump Type: Outdoor Air/Water
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.00 kW
8.00 kW
El input
1.82 kW
3.03 kW
COP
4.40
2.64
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
132 %
Prated
7.20 kW
7.10 kW
SCOP
4.22
3.37
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
6.40 kW
6.30 kW
COP Tj = -7°C
2.43
2.04
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.90 kW
3.80 kW
COP Tj = +2°C
4.16
3.23
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.60 kW
2.90 kW
COP Tj = +7°C
5.62
4.59
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
3.10 kW
2.80 kW
COP Tj = 12°C
7.93
6.10
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
6.40 kW
6.30 kW
COP Tj = Tbiv
2.43
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.22 kW
6.14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.00 kW
1.00 kW
Annual energy consumption Qhe
3525 kWh
4352 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
145 %
COP
3.41
Heating up time
02:23 h:min
Standby power input
35.0 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l