Ecodan Power Inverter 10 AA
Heat Pump Type: Outdoor Air/Water
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.2 kW
11.2 kW
El input
2.52 kW
4.31 kW
COP
4.45
2.6
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
132 %
Prated
10.6 kW
10 kW
SCOP
4.31
3.36
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
9.4 kW
8.9 kW
COP Tj = -7°C
2.75
1.95
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
5.7 kW
5.4 kW
COP Tj = +2°C
4.2
3.22
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.5 kW
4.7 kW
COP Tj = +7°C
5.55
4.79
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
4.3 kW
5.3 kW
COP Tj = 12°C
7.47
6.12
Cdh Tj = +12 °C
0.96
0.98
Pdh Tj = Tbiv
9.4 kW
8.9 kW
COP Tj = Tbiv
2.75
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.96 kW
8.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
1.84
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.64 kW
1.42 kW
Annual energy consumption Qhe
5086 kWh
6141 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
145 %
COP
3.41
Heating up time
01:58 h:min
Standby power input
35 W
Reference hot water temperature
52.5 °C
Mixed water at 40°C
278 l