Login

Subtype

CTC EcoAir 610M

Certificate Holder
CTC AB
Box 309, Näsvägen
SE-341 26 Ljungby
Sweden
Registration number
012-SC0516-18 / Issue 2
Certification Body
RISE CERT
Subtype title
CTC EcoAir 610M
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R407c
Mass of Refrigerant

2,200 kg

Certification Date
n/a
Testing basis
EN 14511:2018, EN 14825:2016, EN12102:2017
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

CTC EcoAir 610M
Configure model
Model name
CTC EcoAir 610M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.88 kW

4.67 kW

El input

1.16 kW

1.47 kW

COP

5.06

3.17

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

124 %

Prated

6.50 kW

6.50 kW

SCOP

4.08

3.17

Tbiv

-14 °C

-13 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.29 kW

4.04 kW

COP Tj = -7°C

3.61

2.66

Pdh Tj = +2°C

2.39 kW

2.34 kW

COP Tj = +2°C

5.08

4.11

Pdh Tj = +7°C

2.46 kW

2.44 kW

COP Tj = +7°C

6.00

5.08

Pdh Tj = 12°C

2.94 kW

2.86 kW

COP Tj = 12°C

7.13

6.08

Pdh Tj = Tbiv

5.15 kW

5.00 kW

COP Tj = Tbiv

2.52

1.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.95 kW

3.64 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.91

1.25

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.98

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

14 W

14 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.55 kW

2.86 kW

Annual energy consumption Qhe

3932 kWh

5052 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

143 %

Prated

6.00 kW

6.60 kW

SCOP

4.81

3.64

Tbiv

-9 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.61 kW

5.89 kW

COP Tj = -7°C

3.03

2.03

Pdh Tj = +2°C

3.46 kW

3.62 kW

COP Tj = +2°C

5.14

3.81

Pdh Tj = +7°C

2.45 kW

2.43 kW

COP Tj = +7°C

5.83

4.86

Pdh Tj = 12°C

2.92 kW

2.83 kW

COP Tj = 12°C

7.27

5.90

Pdh Tj = Tbiv

5.88 kW

5.89 kW

COP Tj = Tbiv

2.66

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.71 kW

5.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.98

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

14 W

14 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.29 kW

1.27 kW

Annual energy consumption Qhe

2579 kWh

3743 kWh