3,000 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
6.94 kW
7.25 kW
El input
1.43 kW
2.35 kW
COP
4.85
3.08
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
134 %
Prated
13.00 kW
14.00 kW
SCOP
4.19
3.41
Tbiv
-12 °C
-12 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.87 kW
8.47 kW
COP Tj = -7°C
3.50
2.85
Pdh Tj = +2°C
6.20 kW
6.10 kW
COP Tj = +2°C
5.25
4.15
Pdh Tj = +7°C
5.90 kW
6.00 kW
COP Tj = +7°C
5.60
4.80
Pdh Tj = 12°C
6.70 kW
6.40 kW
COP Tj = 12°C
7.00
5.80
Pdh Tj = Tbiv
9.58 kW
10.32 kW
COP Tj = Tbiv
3.15
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.30 kW
8.69 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.30
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
7 W
12 W
PSB
25 W
25 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.70 kW
5.30 kW
Annual energy consumption Qhe
7639 kWh
10108 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
153 %
Prated
11.00 kW
12.30 kW
SCOP
5.05
3.90
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.74 kW
10.91 kW
COP Tj = -7°C
3.41
2.48
Pdh Tj = +2°C
6.47 kW
6.66 kW
COP Tj = +2°C
5.08
3.96
Pdh Tj = +7°C
6.86 kW
5.93 kW
COP Tj = +7°C
5.95
4.69
Pdh Tj = 12°C
6.76 kW
6.49 kW
COP Tj = 12°C
7.36
5.81
Pdh Tj = Tbiv
9.74 kW
10.91 kW
COP Tj = Tbiv
3.41
2.48
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.80 kW
11.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.11
2.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
65 °C
65 °C
Poff
25 W
25 W
PTO
7 W
12 W
PSB
25 W
25 W
PCK
37 W
37 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.20 kW
0.70 kW
Annual energy consumption Qhe
4508 kWh
6530 kWh