Login

Subtype

Aquarea Split 16 kW T-CAP (K series)

Certificate Holder
Panasonic Marketing Europe GmbH
Hagenauer Strasse 43, Wiesbaden
65203 Wiesbaden
Germany
Registration number
011-1W0780
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquarea Split 16 kW T-CAP (K series)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,830 kg

Certification Date
15.04.2024
Testing basis
HP KEYMARK certification scheme rules V13
Generate PDF Export model CSV
  • Number of models 3

Models

WH-ADC16K9E8 / WH-UXZ16KE8
Configure model
Model name
WH-ADC16K9E8 / WH-UXZ16KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.65 kW

5.88 kW

COP

4.38

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

5.08 kW

Cooling capacity

13.40

EER

2.64

EN 14825

+7°C/+12°C

Pdesignc

13.00 kW

SEER

4.53

Pdc Tj = 35°C

13.00 kW

EER Tj = 35°C

2.70

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

10.00 kW

EER Tj = 30°C

3.95

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

7.75 kW

EER Tj = 25°C

5.10

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

8.15 kW

EER Tj = 20°C

5.85

Cdc Tj = 20 °C

1.000

Poff

12 W

PTO

0 W

PSB

12 W

PCK

0 W

Annual energy consumption Qce

1004 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

160 %

Prated

16.00 kW

16.00 kW

SCOP

5.88

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

16.00 kW

16.00 kW

COP Tj = +2°C

3.10

2.07

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

10.31 kW

10.54 kW

COP Tj = +7°C

5.56

3.60

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.80 kW

8.92 kW

COP Tj = 12°C

6.89

5.14

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

3.10

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

14 W

14 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3634 kWh

5230 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

150 %

125 %

Prated

19.00 kW

18.00 kW

SCOP

3.83

3.20

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

11.50 kW

10.89 kW

COP Tj = -7°C

2.98

2.59

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

6.63 kW

COP Tj = +2°C

4.71

3.87

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

8.27 kW

7.70 kW

COP Tj = +7°C

5.97

5.31

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

9.34 kW

8.86 kW

COP Tj = 12°C

7.58

7.31

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.50 kW

14.68 kW

COP Tj = Tbiv

2.39

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.09 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.26

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

14 W

14 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.91 kW

6.57 kW

Annual energy consumption Qhe

12233 kWh

13870 kWh

Pdh Tj = -15°C (if TOL<-20°C)

15.50

14.68

COP Tj = -15°C (if TOL<-20°C)

2.39

1.90

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

13.00 kW

16.00 kW

SCOP

4.46

3.31

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

14.10 kW

COP Tj = -7°C

2.89

2.02

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

8.60 kW

COP Tj = +2°C

4.29

3.15

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

8.10 kW

8.00 kW

COP Tj = +7°C

5.83

4.50

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

9.00 kW

9.00 kW

COP Tj = 12°C

7.13

5.82

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

13.00 kW

16.00 kW

COP Tj = Tbiv

2.66

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

14 W

14 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6018 kWh

9984 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.24

Heating up time

0:41 h:min

Standby power input

37.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

86 %

COP

2.14

Heating up time

0:41 h:min

Standby power input

59.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

109 %

COP

2.73

Heating up time

0:41 h:min

Standby power input

43.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

244 l

WH-ADC16K9E8AN / WH-UXZ16KE8
Configure model
Model name
WH-ADC16K9E8AN / WH-UXZ16KE8
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.65 kW

5.88 kW

COP

4.38

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

5.08 kW

Cooling capacity

13.40

EER

2.64

EN 14825

+7°C/+12°C

Pdesignc

13.00 kW

SEER

4.53

Pdc Tj = 35°C

13.00 kW

EER Tj = 35°C

2.70

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

10.00 kW

EER Tj = 30°C

3.95

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

7.75 kW

EER Tj = 25°C

5.10

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

8.15 kW

EER Tj = 20°C

5.85

Cdc Tj = 20 °C

1.000

Poff

12 W

PTO

0 W

PSB

12 W

PCK

0 W

Annual energy consumption Qce

1004 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

160 %

Prated

16.00 kW

16.00 kW

SCOP

5.88

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

16.00 kW

16.00 kW

COP Tj = +2°C

3.10

2.07

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

10.31 kW

10.54 kW

COP Tj = +7°C

5.56

3.60

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.80 kW

8.92 kW

COP Tj = 12°C

6.89

5.14

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

3.10

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

14 W

14 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3634 kWh

5230 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

150 %

125 %

Prated

19.00 kW

18.00 kW

SCOP

3.83

3.20

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

11.50 kW

10.89 kW

COP Tj = -7°C

2.98

2.59

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

6.63 kW

COP Tj = +2°C

4.71

3.87

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

8.27 kW

7.70 kW

COP Tj = +7°C

5.97

5.31

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

9.34 kW

8.86 kW

COP Tj = 12°C

7.58

7.31

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.50 kW

14.68 kW

COP Tj = Tbiv

2.39

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.09 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.26

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

14 W

14 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.91 kW

6.57 kW

Annual energy consumption Qhe

12233 kWh

13870 kWh

Pdh Tj = -15°C (if TOL<-20°C)

15.50

14.68

COP Tj = -15°C (if TOL<-20°C)

2.39

1.90

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

13.00 kW

16.00 kW

SCOP

4.46

3.31

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

14.10 kW

COP Tj = -7°C

2.89

2.02

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

8.60 kW

COP Tj = +2°C

4.29

3.15

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

8.10 kW

8.00 kW

COP Tj = +7°C

5.83

4.50

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

9.00 kW

9.00 kW

COP Tj = 12°C

7.13

5.82

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

13.00 kW

16.00 kW

COP Tj = Tbiv

2.66

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

14 W

14 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6018 kWh

9984 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.24

Heating up time

0:41 h:min

Standby power input

37.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

244 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

86 %

COP

2.14

Heating up time

0:41 h:min

Standby power input

59.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

244 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

109 %

COP

2.73

Heating up time

0:41 h:min

Standby power input

43.0 W

Reference hot water temperature

52.9 °C

Mixed water at 40°C

244 l

WH-SXC16K9E8 / WH-UXZ16KE8
Configure model
Model name
WH-SXC16K9E8 / WH-UXZ16KE8
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.65 kW

5.88 kW

COP

4.38

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

El input

5.08 kW

Cooling capacity

13.40

EER

2.64

EN 14825

+7°C/+12°C

Pdesignc

13.00 kW

SEER

4.53

Pdc Tj = 35°C

13.00 kW

EER Tj = 35°C

2.70

Cdc Tj = 35 °C

1.000

Pdc Tj = 30°C

10.00 kW

EER Tj = 30°C

3.95

Cdc Tj = 30 °C

1.000

Pdc Tj = 25°C

7.75 kW

EER Tj = 25°C

5.10

Cdc Tj = 25 °C

1.000

Pdc Tj = 20°C

8.15 kW

EER Tj = 20°C

5.85

Cdc Tj = 20 °C

1.000

Poff

12 W

PTO

0 W

PSB

12 W

PCK

0 W

Annual energy consumption Qce

1004 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

160 %

Prated

16.00 kW

16.00 kW

SCOP

5.88

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

16.00 kW

16.00 kW

COP Tj = +2°C

3.10

2.07

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

10.31 kW

10.54 kW

COP Tj = +7°C

5.56

3.60

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.80 kW

8.92 kW

COP Tj = 12°C

6.89

5.14

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

3.10

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.10

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

14 W

14 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3634 kWh

5230 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

150 %

125 %

Prated

19.00 kW

18.00 kW

SCOP

3.83

3.20

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

11.50 kW

10.89 kW

COP Tj = -7°C

2.98

2.59

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

6.63 kW

COP Tj = +2°C

4.71

3.87

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

8.27 kW

7.70 kW

COP Tj = +7°C

5.97

5.31

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

9.34 kW

8.86 kW

COP Tj = 12°C

7.58

7.31

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.50 kW

14.68 kW

COP Tj = Tbiv

2.39

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.09 kW

11.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.26

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

14 W

14 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.91 kW

6.57 kW

Annual energy consumption Qhe

12233 kWh

13870 kWh

Pdh Tj = -15°C (if TOL<-20°C)

15.50

14.68

COP Tj = -15°C (if TOL<-20°C)

2.39

1.90

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

46 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

13.00 kW

16.00 kW

SCOP

4.46

3.31

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

14.10 kW

COP Tj = -7°C

2.89

2.02

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

8.60 kW

COP Tj = +2°C

4.29

3.15

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

8.10 kW

8.00 kW

COP Tj = +7°C

5.83

4.50

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

9.00 kW

9.00 kW

COP Tj = 12°C

7.13

5.82

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

13.00 kW

16.00 kW

COP Tj = Tbiv

2.66

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

12 W

12 W

PTO

14 W

14 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6018 kWh

9984 kWh