4,927 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
9.00 kW
El input
1.84 kW
2.81 kW
COP
4.90
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
70 dB(A)
70 dB(A)
Sound power level outdoor
77 dB(A)
77 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
124 %
113 %
Prated
22.77 kW
21.70 kW
SCOP
3.17
2.89
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
19.50 kW
19.00 kW
COP Tj = -7°C
2.37
2.05
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
12.30 kW
11.90 kW
COP Tj = +2°C
3.21
2.97
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.20 kW
7.70 kW
COP Tj = +7°C
3.83
3.43
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.80 kW
3.90 kW
COP Tj = 12°C
3.63
3.57
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
22.80 kW
21.70 kW
COP Tj = Tbiv
2.03
1.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.80 kW
21.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.03
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
55 W
55 W
PTO
55 W
55 W
PSB
55 W
55 W
PCK
1 W
1 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
14856 kWh
15511 kWh