Login

Subtype

CTC EcoAir 700-series

Certificate Holder
CTC AB
Box 309, Näsvägen
SE-341 26 Ljungby
Sweden
Registration number
012-C700200 / Issue 1
Certification Body
RISE CERT
Subtype title
CTC EcoAir 700-series
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,800 kg

Certification Date
19.02.2024
Testing basis
EN 14511:2022, EN 14825:2022, EN 12102:2017
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

CTC EcoAir 708M 400V
Configure model
Model name
CTC EcoAir 708M 400V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.02 kW

4.79 kW

El input

1.03 kW

1.46 kW

COP

4.89

3.28

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

46 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

151 %

Prated

5.30 kW

5.00 kW

SCOP

5.03

3.84

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.74 kW

4.43 kW

COP Tj = -7°C

3.30

2.43

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.91 kW

2.69 kW

COP Tj = +2°C

4.99

3.82

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.11 kW

2.03 kW

COP Tj = +7°C

6.24

4.85

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

2.44 kW

2.37 kW

COP Tj = 12°C

8.00

6.16

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

4.95 kW

4.61 kW

COP Tj = Tbiv

2.93

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.95 kW

4.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

2.14

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2176 kWh

2687 kWh

CTC EcoAir 708M 230V
Configure model
Model name
CTC EcoAir 708M 230V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.02 kW

4.79 kW

El input

1.03 kW

1.46 kW

COP

4.89

3.28

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

46 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

151 %

Prated

5.30 kW

5.00 kW

SCOP

5.03

3.84

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.74 kW

4.43 kW

COP Tj = -7°C

3.30

2.43

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.91 kW

2.69 kW

COP Tj = +2°C

4.99

3.82

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.11 kW

2.03 kW

COP Tj = +7°C

6.24

4.85

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

2.44 kW

2.37 kW

COP Tj = 12°C

8.00

6.16

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

4.95 kW

4.61 kW

COP Tj = Tbiv

2.93

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.95 kW

4.61 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.93

2.14

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2176 kWh

2687 kWh

CTC EcoAir 712M 400V
Configure model
Model name
CTC EcoAir 712M 400V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.02 kW

4.79 kW

El input

1.03 kW

1.46 kW

COP

4.89

3.28

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

151 %

Prated

7.30 kW

7.00 kW

SCOP

5.00

3.86

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

5.97 kW

COP Tj = -7°C

3.07

2.31

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.84 kW

3.71 kW

COP Tj = +2°C

4.94

3.77

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.54 kW

2.39 kW

COP Tj = +7°C

6.46

5.16

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.45 kW

2.37 kW

COP Tj = 12°C

8.23

6.31

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.23 kW

6.78 kW

COP Tj = Tbiv

2.54

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.23 kW

6.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3016 kWh

3751 kWh

CTC EcoAir 712M 230V
Configure model
Model name
CTC EcoAir 712M 230V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.02 kW

4.79 kW

El input

1.03 kW

1.46 kW

COP

4.89

3.28

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

151 %

Prated

7.30 kW

7.00 kW

SCOP

5.00

3.86

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

5.97 kW

COP Tj = -7°C

3.07

2.31

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.84 kW

3.71 kW

COP Tj = +2°C

4.94

3.77

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.54 kW

2.39 kW

COP Tj = +7°C

6.46

5.16

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.45 kW

2.37 kW

COP Tj = 12°C

8.23

6.31

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

7.23 kW

6.78 kW

COP Tj = Tbiv

2.54

1.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.23 kW

6.78 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3016 kWh

3751 kWh