3,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.10 kW
3.99 kW
El input
0.75 kW
1.29 kW
COP
5.54
3.09
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
272 %
185 %
Prated
8.57 kW
8.64 kW
SCOP
6.88
4.71
Tbiv
2 °C
2 °C
TOL
-22 °C
-22 °C
Pdh Tj = +2°C
8.57 kW
8.64 kW
COP Tj = +2°C
3.51
2.40
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.99 kW
5.93 kW
COP Tj = +7°C
6.41
4.14
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.14 kW
3.82 kW
COP Tj = 12°C
8.36
5.99
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
8.57 kW
8.64 kW
COP Tj = Tbiv
3.51
2.40
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.57 kW
8.64 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.51
2.40
WTOL
35 °C
55 °C
Poff
13 W
13 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1665 kWh
2451 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
135 %
Prated
8.78 kW
8.17 kW
SCOP
4.50
3.44
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.32 kW
5.44 kW
COP Tj = -7°C
4.00
2.84
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.36 kW
3.30 kW
COP Tj = +2°C
5.10
4.25
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.73 kW
3.61 kW
COP Tj = +7°C
7.24
5.52
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
4.03 kW
3.90 kW
COP Tj = 12°C
7.70
6.57
Cdh Tj = +12 °C
0.97
0.97
Pdh Tj = Tbiv
7.62 kW
7.09 kW
COP Tj = Tbiv
2.47
1.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
5.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.35
WTOL
35 °C
55 °C
Poff
13 W
13 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.08 kW
2.22 kW
Annual energy consumption Qhe
4812 kWh
5852 kWh
Pdh Tj = -15°C (if TOL<-20°C)
7.10
7.28
COP Tj = -15°C (if TOL<-20°C)
2.77
1.99
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
141 %
Prated
7.58 kW
7.40 kW
SCOP
4.86
3.60
Tbiv
-10 °C
-10 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.25 kW
7.03 kW
COP Tj = -7°C
2.92
2.09
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
4.33 kW
4.28 kW
COP Tj = +2°C
4.69
3.45
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.72 kW
3.54 kW
COP Tj = +7°C
6.89
5.07
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.75 kW
4.09 kW
COP Tj = 12°C
7.43
6.60
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
7.58 kW
7.40 kW
COP Tj = Tbiv
2.52
1.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.58 kW
7.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.75
WTOL
35 °C
55 °C
Poff
13 W
13 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3225 kWh
4255 kWh