Login

Subtype

Intelligent Inverter Heat Pump R290- G60+G60S

Certificate Holder
Guangdong PHNIX Eco-Energy Solutions Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-13
Certification Body
BRE Global Limited
Subtype title
Intelligent Inverter Heat Pump R290- G60+G60S
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,400 kg

Certification Date
15.03.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

G60
Configure model
Model name
G60
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.98 kW

17.09 kW

El input

4.02 kW

5.90 kW

COP

4.22

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

141 %

Prated

16.66 kW

17.07 kW

SCOP

4.65

3.61

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

14.74 kW

15.10 kW

COP Tj = -7°C

2.76

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.98 kW

9.37 kW

COP Tj = +2°C

4.52

3.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.82 kW

6.02 kW

COP Tj = +7°C

6.43

4.98

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.06 kW

5.80 kW

COP Tj = 12°C

8.11

6.41

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.74 kW

15.10 kW

COP Tj = Tbiv

2.76

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.05 kW

15.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

12 W

12 W

PSB

11 W

11 W

PCK

86 W

86 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

2.03 kW

Annual energy consumption Qhe

7404 kWh

9777 kWh

G60S
Configure model
Model name
G60S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.02 kW

16.92 kW

El input

4.03 kW

5.57 kW

COP

4.23

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

142 %

Prated

16.71 kW

16.62 kW

SCOP

4.64

3.62

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

14.78 kW

14.70 kW

COP Tj = -7°C

2.85

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

9.16 kW

9.09 kW

COP Tj = +2°C

4.49

3.54

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.80 kW

5.76 kW

COP Tj = +7°C

6.27

4.87

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.04 kW

5.86 kW

COP Tj = 12°C

8.36

6.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

14.78 kW

14.70 kW

COP Tj = Tbiv

2.85

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.57 kW

14.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

88 W

88 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.14 kW

2.57 kW

Annual energy consumption Qhe

7440 kWh

9486 kWh