Login

Subtype

Intelligent Inverter Heat Pump R290- G40+G40S

Certificate Holder
Guangdong PHNIX Eco-Energy Solutions Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-12
Certification Body
BRE Global Limited
Subtype title
Intelligent Inverter Heat Pump R290- G40+G40S
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,000 kg

Certification Date
15.03.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

G40
Configure model
Model name
G40
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.48 kW

9.17 kW

El input

2.30 kW

3.21 kW

COP

4.56

2.86

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

143 %

Prated

11.62 kW

11.83 kW

SCOP

4.67

3.66

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

10.28 kW

10.47 kW

COP Tj = -7°C

2.97

2.31

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.30 kW

6.43 kW

COP Tj = +2°C

4.48

3.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.58 kW

4.33 kW

COP Tj = +7°C

6.50

5.09

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.33 kW

5.16 kW

COP Tj = 12°C

8.31

6.65

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.28 kW

10.47 kW

COP Tj = Tbiv

2.97

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.79 kW

9.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

12 W

12 W

PSB

11 W

11 W

PCK

83 W

83 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.83 kW

1.85 kW

Annual energy consumption Qhe

5144 kWh

6679 kWh

G40S
Configure model
Model name
G40S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.72 kW

9.67 kW

El input

2.13 kW

3.12 kW

COP

4.57

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

141 %

Prated

11.63 kW

11.71 kW

SCOP

4.71

3.60

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

10.29 kW

10.36 kW

COP Tj = -7°C

2.99

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.30 kW

6.45 kW

COP Tj = +2°C

4.54

3.45

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.19 kW

4.25 kW

COP Tj = +7°C

6.37

4.93

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.87 kW

5.03 kW

COP Tj = 12°C

8.09

6.40

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.29 kW

10.36 kW

COP Tj = Tbiv

2.99

2.28

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.71 kW

9.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

12 W

12 W

PSB

10 W

10 W

PCK

48 W

48 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.92 kW

1.82 kW

Annual energy consumption Qhe

5105 kWh

6718 kWh