Login

Subtype

Intelligent Inverter Heat Pump R290- G15+G20

Certificate Holder
Guangdong PHNIX Eco-Energy Solutions Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-11
Certification Body
BRE Global Limited
Subtype title
Intelligent Inverter Heat Pump R290- G15+G20
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,650 kg

Certification Date
15.03.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

G15
Configure model
Model name
G15
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.07 kW

4.14 kW

El input

0.85 kW

1.40 kW

COP

4.79

2.95

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

54 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

132 %

Prated

4.45 kW

4.47 kW

SCOP

4.83

3.36

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

3.94 kW

3.95 kW

COP Tj = -7°C

3.10

2.23

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.55 kW

2.57 kW

COP Tj = +2°C

4.87

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.01 kW

1.75 kW

COP Tj = +7°C

6.59

4.16

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.29 kW

2.19 kW

COP Tj = 12°C

7.21

6.13

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.94 kW

3.95 kW

COP Tj = Tbiv

3.10

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.08 kW

4.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.37 kW

0.36 kW

Annual energy consumption Qhe

1903 kWh

2744 kWh

G20
Configure model
Model name
G20
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

6.95 kW

El input

1.46 kW

2.31 kW

COP

4.78

3.01

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

138 %

Prated

7.01 kW

6.64 kW

SCOP

4.78

3.51

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

6.20 kW

5.87 kW

COP Tj = -7°C

2.93

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.78 kW

3.71 kW

COP Tj = +2°C

4.59

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.49 kW

2.42 kW

COP Tj = +7°C

6.75

4.69

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.49 kW

2.29 kW

COP Tj = 12°C

8.37

6.72

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.20 kW

5.87 kW

COP Tj = Tbiv

2.93

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.69 kW

5.04 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.33 kW

1.60 kW

Annual energy consumption Qhe

3033 kWh

3904 kWh