Login

Subtype

Intelligent Inverter Heat Pump R290- U60+U60S

Certificate Holder
Guangdong PHNIX Eco-Energy Solutions Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-17
Certification Body
BRE Global Limited
Subtype title
Intelligent Inverter Heat Pump R290- U60+U60S
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,400 kg

Certification Date
15.03.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

U60
Configure model
Model name
U60
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.01 kW

17.30 kW

El input

3.73 kW

5.64 kW

COP

4.57

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

141 %

Prated

14.71 kW

14.85 kW

SCOP

4.87

3.61

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

13.01 kW

13.14 kW

COP Tj = -7°C

3.13

2.31

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.97 kW

8.11 kW

COP Tj = +2°C

4.83

3.53

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.17 kW

5.25 kW

COP Tj = +7°C

6.12

4.57

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.81 kW

5.60 kW

COP Tj = 12°C

8.32

6.58

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.01 kW

13.14 kW

COP Tj = Tbiv

3.13

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.39 kW

14.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

15 W

15 W

PSB

13 W

13 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.32 kW

0.06 kW

Annual energy consumption Qhe

6244 kWh

8502 kWh

U60S
Configure model
Model name
U60S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.21 kW

16.47 kW

El input

3.65 kW

5.28 kW

COP

4.71

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

143 %

Prated

14.55 kW

14.72 kW

SCOP

4.90

3.65

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

12.87 kW

13.02 kW

COP Tj = -7°C

2.99

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.85 kW

7.93 kW

COP Tj = +2°C

4.81

3.60

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.67 kW

5.84 kW

COP Tj = +7°C

6.80

4.78

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.57 kW

7.14 kW

COP Tj = 12°C

8.58

6.70

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.87 kW

13.02 kW

COP Tj = Tbiv

2.99

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.42 kW

14.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

1.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

48 W

48 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.16 kW

Annual energy consumption Qhe

6136 kWh

8323 kWh