Login

Subtype

Intelligent Inverter Heat Pump R290- U40+U40S

Certificate Holder
Guangdong PHNIX Eco-Energy Solutions Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-16
Certification Body
BRE Global Limited
Subtype title
Intelligent Inverter Heat Pump R290- U40+U40S
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,980 kg

Certification Date
15.03.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

U40
Configure model
Model name
U40
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.98 kW

9.25 kW

El input

2.13 kW

3.00 kW

COP

4.67

3.09

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

143 %

Prated

9.84 kW

9.80 kW

SCOP

4.85

3.65

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

8.70 kW

8.67 kW

COP Tj = -7°C

3.17

2.39

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.31 kW

5.28 kW

COP Tj = +2°C

4.82

3.61

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.68 kW

3.66 kW

COP Tj = +7°C

5.98

4.60

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.18 kW

3.91 kW

COP Tj = 12°C

8.38

5.89

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.70 kW

8.67 kW

COP Tj = Tbiv

3.17

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.75 kW

9.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

2.11

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

12 W

12 W

PSB

11 W

11 W

PCK

44 W

44 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.09 kW

0.49 kW

Annual energy consumption Qhe

4187 kWh

5554 kWh

U40S
Configure model
Model name
U40S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.92 kW

9.25 kW

El input

2.21 kW

3.02 kW

COP

4.50

3.06

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

138 %

Prated

9.83 kW

9.83 kW

SCOP

4.80

3.53

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

8.70 kW

8.69 kW

COP Tj = -7°C

3.18

2.35

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.30 kW

5.31 kW

COP Tj = +2°C

4.70

3.45

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.53 kW

4.29 kW

COP Tj = +7°C

6.22

4.61

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.16 kW

4.99 kW

COP Tj = 12°C

8.34

6.19

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.70 kW

8.69 kW

COP Tj = Tbiv

3.18

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.70 kW

9.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

48 W

48 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.13 kW

0.64 kW

Annual energy consumption Qhe

4232 kWh

5748 kWh