0,750 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
4.42 kW
El input
0.82 kW
1.53 kW
COP
4.90
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
141 %
Prated
4.48 kW
4.75 kW
SCOP
4.96
3.59
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
3.96 kW
4.20 kW
COP Tj = -7°C
3.14
2.22
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.63 kW
2.63 kW
COP Tj = +2°C
4.91
3.52
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.96 kW
1.79 kW
COP Tj = +7°C
6.63
4.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.33 kW
2.04 kW
COP Tj = 12°C
8.81
6.26
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.96 kW
4.20 kW
COP Tj = Tbiv
3.14
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.24 kW
4.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
11 W
11 W
PSB
10 W
10 W
PCK
42 W
42 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.23 kW
0.28 kW
Annual energy consumption Qhe
1864 kWh
2735 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.10 kW
5.47 kW
El input
1.26 kW
1.84 kW
COP
4.83
2.98
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
135 %
Prated
5.63 kW
5.58 kW
SCOP
4.87
3.46
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
4.98 kW
4.93 kW
COP Tj = -7°C
3.14
2.20
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.06 kW
3.03 kW
COP Tj = +2°C
4.60
3.35
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.07 kW
1.99 kW
COP Tj = +7°C
6.74
4.54
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.49 kW
2.18 kW
COP Tj = 12°C
8.96
6.35
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
4.98 kW
4.93 kW
COP Tj = Tbiv
3.14
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.49 kW
5.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.80
1.93
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
12 W
12 W
PSB
11 W
11 W
PCK
44 W
44 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.14 kW
0.44 kW
Annual energy consumption Qhe
2387 kWh
3333 kWh