Login

Subtype

VWF 57/4

Certificate Holder
Vaillant Deutschland GmbH & Co KG
Berghauser Straße 40
42859 Remscheid
Germany
Registration number
011-1W0749
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
VWF 57/4
Driving energy
n/a
Heat Pump Type
Brine/Water
Refrigerant
R410A
Mass of Refrigerant

1,500 kg

Certification Date
28.04.2021
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

VWF 57/4
Configure model
Model name
VWF 57/4
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.28 kW

5.34 kW

El input

1.20 kW

1.85 kW

COP

4.41

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

41 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

132 %

Prated

5.28 kW

5.34 kW

SCOP

4.85

3.51

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.34 kW

COP Tj = +2°C

4.41

2.89

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.27 kW

5.32 kW

COP Tj = +7°C

4.69

3.23

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

5.26 kW

5.29 kW

COP Tj = 12°C

5.17

3.93

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.28 kW

5.34 kW

COP Tj = Tbiv

4.41

2.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.41

2.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

4 W

4 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1453 kWh

2036 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

41 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

134 %

Prated

5.28 kW

5.34 kW

SCOP

4.91

3.55

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.27 kW

5.32 kW

COP Tj = -7°C

4.80

3.34

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

5.26 kW

5.30 kW

COP Tj = +2°C

5.08

3.72

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.25 kW

5.29 kW

COP Tj = +7°C

5.30

4.08

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.25 kW

5.28 kW

COP Tj = 12°C

5.36

4.41

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.28 kW

5.34 kW

COP Tj = Tbiv

4.41

2.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.41

2.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

4 W

4 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2648 kWh

3713 kWh

Cdh Tj = -15 °C

0.99

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

41 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

5.28 kW

5.34 kW

SCOP

4.79

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.27 kW

5.34 kW

COP Tj = -7°C

4.46

2.99

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

5.27 kW

5.31 kW

COP Tj = +2°C

4.76

3.44

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.26 kW

5.30 kW

COP Tj = +7°C

5.06

3.79

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.25 kW

5.28 kW

COP Tj = 12°C

5.40

4.22

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.28 kW

5.34 kW

COP Tj = Tbiv

4.41

2.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.41

2.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

4 W

4 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2275 kWh

3171 kWh

VWF 58/4
Configure model
Model name
VWF 58/4
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.28 kW

5.34 kW

El input

1.20 kW

1.85 kW

COP

4.41

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

41 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

132 %

Prated

5.28 kW

5.34 kW

SCOP

4.85

3.51

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.28 kW

5.34 kW

COP Tj = +2°C

4.41

2.89

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.27 kW

5.32 kW

COP Tj = +7°C

4.69

3.23

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

5.26 kW

5.29 kW

COP Tj = 12°C

5.17

3.93

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.28 kW

5.34 kW

COP Tj = Tbiv

4.41

2.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.41

2.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

4 W

4 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1453 kWh

2036 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

41 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

134 %

Prated

5.28 kW

5.34 kW

SCOP

4.91

3.55

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.27 kW

5.32 kW

COP Tj = -7°C

4.80

3.34

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

5.26 kW

5.30 kW

COP Tj = +2°C

5.08

3.72

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.25 kW

5.29 kW

COP Tj = +7°C

5.30

4.08

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.25 kW

5.28 kW

COP Tj = 12°C

5.36

4.41

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.28 kW

5.34 kW

COP Tj = Tbiv

4.41

2.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.41

2.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

4 W

4 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2648 kWh

3713 kWh

Cdh Tj = -15 °C

0.99

1.00

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

41 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

131 %

Prated

5.28 kW

5.34 kW

SCOP

4.79

3.48

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.27 kW

5.34 kW

COP Tj = -7°C

4.46

2.99

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

5.27 kW

5.31 kW

COP Tj = +2°C

4.76

3.44

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.26 kW

5.30 kW

COP Tj = +7°C

5.06

3.79

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.25 kW

5.28 kW

COP Tj = 12°C

5.40

4.22

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

5.28 kW

5.34 kW

COP Tj = Tbiv

4.41

2.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.28 kW

5.34 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.41

2.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

4 W

4 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2275 kWh

3171 kWh