1,200 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.75 kW
5.12 kW
El input
1.32 kW
1.91 kW
COP
4.36
2.68
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
126 %
Prated
5.70 kW
5.10 kW
SCOP
4.66
3.36
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.75 kW
5.12 kW
COP Tj = +2°C
4.36
2.68
Cdh Tj = +2 °C
0.990
0.993
Pdh Tj = +7°C
5.82 kW
5.28 kW
COP Tj = +7°C
4.60
3.12
Cdh Tj = +7 °C
0.989
0.992
Pdh Tj = 12°C
5.92 kW
5.52 kW
COP Tj = 12°C
4.99
3.85
Cdh Tj = +12 °C
0.989
0.990
Pdh Tj = Tbiv
5.75 kW
5.12 kW
COP Tj = Tbiv
4.36
2.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.36
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1633 kWh
2027 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
127 %
Prated
9.60 kW
8.80 kW
SCOP
4.43
3.37
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.89 kW
5.39 kW
COP Tj = -7°C
4.94
3.47
Cdh Tj = -7 °C
0.989
0.991
Pdh Tj = +2°C
5.94 kW
5.51 kW
COP Tj = +2°C
5.08
3.83
Cdh Tj = +2 °C
0.988
0.990
Pdh Tj = +7°C
5.98 kW
5.61 kW
COP Tj = +7°C
5.22
4.12
Cdh Tj = +7 °C
0.988
0.990
Pdh Tj = 12°C
5.96 kW
5.68 kW
COP Tj = 12°C
5.19
4.36
Cdh Tj = +12 °C
0.988
0.989
Pdh Tj = Tbiv
5.89 kW
5.39 kW
COP Tj = Tbiv
4.94
3.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.36
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.85 kW
3.68 kW
Annual energy consumption Qhe
5345 kWh
6441 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
6.50 kW
5.90 kW
SCOP
4.72
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.77 kW
5.20 kW
COP Tj = -7°C
4.51
2.89
Cdh Tj = -7 °C
0.989
0.992
Pdh Tj = +2°C
5.83 kW
5.37 kW
COP Tj = +2°C
4.74
3.40
Cdh Tj = +2 °C
0.989
0.991
Pdh Tj = +7°C
5.89 kW
5.49 kW
COP Tj = +7°C
4.99
3.75
Cdh Tj = +7 °C
0.989
0.990
Pdh Tj = 12°C
5.96 kW
5.60 kW
COP Tj = 12°C
5.25
4.13
Cdh Tj = +12 °C
0.988
0.990
Pdh Tj = Tbiv
5.77 kW
5.20 kW
COP Tj = Tbiv
4.51
2.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.43
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
0.78 kW
Annual energy consumption Qhe
2847 kWh
3592 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.86 kW
6.97 kW
El input
1.33 kW
2.00 kW
COP
5.90
3.49
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
252 %
175 %
Prated
7.80 kW
7.00 kW
SCOP
6.49
4.57
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.86 kW
6.97 kW
COP Tj = +2°C
5.90
3.49
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
7.98 kW
7.31 kW
COP Tj = +7°C
6.30
4.13
Cdh Tj = +7 °C
0.994
0.996
Pdh Tj = 12°C
8.13 kW
7.75 kW
COP Tj = 12°C
6.90
5.29
Cdh Tj = +12 °C
0.994
0.995
Pdh Tj = Tbiv
7.86 kW
6.97 kW
COP Tj = Tbiv
5.90
3.49
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1606 kWh
2046 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
225 %
170 %
Prated
13.20 kW
12.30 kW
SCOP
5.83
4.45
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.13 kW
7.56 kW
COP Tj = -7°C
6.85
4.78
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
8.17 kW
7.74 kW
COP Tj = +2°C
7.04
5.28
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
8.22 kW
7.86 kW
COP Tj = +7°C
7.22
5.74
Cdh Tj = +7 °C
0.994
0.995
Pdh Tj = 12°C
8.22 kW
7.93 kW
COP Tj = 12°C
7.18
6.06
Cdh Tj = +12 °C
0.994
0.994
Pdh Tj = Tbiv
8.13 kW
7.56 kW
COP Tj = Tbiv
6.85
4.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.34 kW
5.33 kW
Annual energy consumption Qhe
5579 kWh
6815 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
250 %
176 %
Prated
8.90 kW
8.10 kW
SCOP
6.45
4.60
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.93 kW
7.17 kW
COP Tj = -7°C
6.11
3.81
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
8.02 kW
7.49 kW
COP Tj = +2°C
6.45
4.59
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
8.11 kW
7.68 kW
COP Tj = +7°C
6.81
5.13
Cdh Tj = +7 °C
0.994
0.995
Pdh Tj = 12°C
8.21 kW
7.87 kW
COP Tj = 12°C
7.19
5.75
Cdh Tj = +12 °C
0.994
0.995
Pdh Tj = Tbiv
7.93 kW
7.17 kW
COP Tj = Tbiv
6.11
3.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.04 kW
1.13 kW
Annual energy consumption Qhe
2852 kWh
3634 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.75 kW
5.12 kW
El input
1.32 kW
1.91 kW
COP
4.36
2.68
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
126 %
Prated
5.70 kW
5.10 kW
SCOP
4.66
3.36
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.75 kW
5.12 kW
COP Tj = +2°C
4.36
2.68
Cdh Tj = +2 °C
0.990
0.993
Pdh Tj = +7°C
5.82 kW
5.28 kW
COP Tj = +7°C
4.60
3.12
Cdh Tj = +7 °C
0.989
0.992
Pdh Tj = 12°C
5.92 kW
5.52 kW
COP Tj = 12°C
4.99
3.85
Cdh Tj = +12 °C
0.989
0.990
Pdh Tj = Tbiv
5.75 kW
5.12 kW
COP Tj = Tbiv
4.36
2.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.36
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1633 kWh
2027 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
127 %
Prated
9.60 kW
8.80 kW
SCOP
4.43
3.37
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.89 kW
5.39 kW
COP Tj = -7°C
4.94
3.47
Cdh Tj = -7 °C
0.989
0.991
Pdh Tj = +2°C
5.94 kW
5.51 kW
COP Tj = +2°C
5.08
3.83
Cdh Tj = +2 °C
0.988
0.990
Pdh Tj = +7°C
5.98 kW
5.61 kW
COP Tj = +7°C
5.22
4.12
Cdh Tj = +7 °C
0.988
0.990
Pdh Tj = 12°C
5.96 kW
5.68 kW
COP Tj = 12°C
5.19
4.36
Cdh Tj = +12 °C
0.988
0.989
Pdh Tj = Tbiv
5.89 kW
5.39 kW
COP Tj = Tbiv
4.94
3.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.36
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.85 kW
3.68 kW
Annual energy consumption Qhe
5345 kWh
6441 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
6.50 kW
5.90 kW
SCOP
4.72
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.77 kW
5.20 kW
COP Tj = -7°C
4.51
2.89
Cdh Tj = -7 °C
0.989
0.992
Pdh Tj = +2°C
5.83 kW
5.37 kW
COP Tj = +2°C
4.74
3.40
Cdh Tj = +2 °C
0.989
0.991
Pdh Tj = +7°C
5.89 kW
5.49 kW
COP Tj = +7°C
4.99
3.75
Cdh Tj = +7 °C
0.989
0.990
Pdh Tj = 12°C
5.96 kW
5.60 kW
COP Tj = 12°C
5.25
4.13
Cdh Tj = +12 °C
0.988
0.990
Pdh Tj = Tbiv
5.77 kW
5.20 kW
COP Tj = Tbiv
4.51
2.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.43
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
0.78 kW
Annual energy consumption Qhe
2847 kWh
3592 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.86 kW
6.97 kW
El input
1.33 kW
2.00 kW
COP
5.90
3.49
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
252 %
175 %
Prated
7.80 kW
7.00 kW
SCOP
6.49
4.57
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.86 kW
6.97 kW
COP Tj = +2°C
5.90
3.49
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
7.98 kW
7.31 kW
COP Tj = +7°C
6.30
4.13
Cdh Tj = +7 °C
0.994
0.996
Pdh Tj = 12°C
8.13 kW
7.75 kW
COP Tj = 12°C
6.90
5.29
Cdh Tj = +12 °C
0.994
0.995
Pdh Tj = Tbiv
7.86 kW
6.97 kW
COP Tj = Tbiv
5.90
3.49
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1606 kWh
2046 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
225 %
170 %
Prated
13.20 kW
12.30 kW
SCOP
5.83
4.45
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.13 kW
7.56 kW
COP Tj = -7°C
6.85
4.78
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
8.17 kW
7.74 kW
COP Tj = +2°C
7.04
5.28
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
8.22 kW
7.86 kW
COP Tj = +7°C
7.22
5.74
Cdh Tj = +7 °C
0.994
0.995
Pdh Tj = 12°C
8.22 kW
7.93 kW
COP Tj = 12°C
7.18
6.06
Cdh Tj = +12 °C
0.994
0.994
Pdh Tj = Tbiv
8.13 kW
7.56 kW
COP Tj = Tbiv
6.85
4.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.34 kW
5.33 kW
Annual energy consumption Qhe
5579 kWh
6815 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
250 %
176 %
Prated
8.90 kW
8.10 kW
SCOP
6.45
4.60
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.93 kW
7.17 kW
COP Tj = -7°C
6.11
3.81
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
8.02 kW
7.49 kW
COP Tj = +2°C
6.45
4.59
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
8.11 kW
7.68 kW
COP Tj = +7°C
6.81
5.13
Cdh Tj = +7 °C
0.994
0.995
Pdh Tj = 12°C
8.21 kW
7.87 kW
COP Tj = 12°C
7.19
5.75
Cdh Tj = +12 °C
0.994
0.995
Pdh Tj = Tbiv
7.93 kW
7.17 kW
COP Tj = Tbiv
6.11
3.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.04 kW
1.13 kW
Annual energy consumption Qhe
2852 kWh
3634 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.75 kW
5.12 kW
El input
1.32 kW
1.91 kW
COP
4.36
2.68
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
126 %
Prated
5.70 kW
5.10 kW
SCOP
4.66
3.36
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.75 kW
5.12 kW
COP Tj = +2°C
4.36
2.68
Cdh Tj = +2 °C
0.990
0.993
Pdh Tj = +7°C
5.82 kW
5.28 kW
COP Tj = +7°C
4.60
3.12
Cdh Tj = +7 °C
0.989
0.992
Pdh Tj = 12°C
5.92 kW
5.52 kW
COP Tj = 12°C
4.99
3.85
Cdh Tj = +12 °C
0.989
0.990
Pdh Tj = Tbiv
5.75 kW
5.12 kW
COP Tj = Tbiv
4.36
2.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.36
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1633 kWh
2027 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
127 %
Prated
9.60 kW
8.80 kW
SCOP
4.43
3.37
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.89 kW
5.39 kW
COP Tj = -7°C
4.94
3.47
Cdh Tj = -7 °C
0.989
0.991
Pdh Tj = +2°C
5.94 kW
5.51 kW
COP Tj = +2°C
5.08
3.83
Cdh Tj = +2 °C
0.988
0.990
Pdh Tj = +7°C
5.98 kW
5.61 kW
COP Tj = +7°C
5.22
4.12
Cdh Tj = +7 °C
0.988
0.990
Pdh Tj = 12°C
5.96 kW
5.68 kW
COP Tj = 12°C
5.19
4.36
Cdh Tj = +12 °C
0.988
0.989
Pdh Tj = Tbiv
5.89 kW
5.39 kW
COP Tj = Tbiv
4.94
3.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.36
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.85 kW
3.68 kW
Annual energy consumption Qhe
5345 kWh
6441 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
6.50 kW
5.90 kW
SCOP
4.72
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.77 kW
5.20 kW
COP Tj = -7°C
4.51
2.89
Cdh Tj = -7 °C
0.989
0.992
Pdh Tj = +2°C
5.83 kW
5.37 kW
COP Tj = +2°C
4.74
3.40
Cdh Tj = +2 °C
0.989
0.991
Pdh Tj = +7°C
5.89 kW
5.49 kW
COP Tj = +7°C
4.99
3.75
Cdh Tj = +7 °C
0.989
0.990
Pdh Tj = 12°C
5.96 kW
5.60 kW
COP Tj = 12°C
5.25
4.13
Cdh Tj = +12 °C
0.988
0.990
Pdh Tj = Tbiv
5.77 kW
5.20 kW
COP Tj = Tbiv
4.51
2.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.43
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
0.78 kW
Annual energy consumption Qhe
2847 kWh
3592 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2:04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2:04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2:04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.86 kW
6.97 kW
El input
1.33 kW
2.00 kW
COP
5.90
3.49
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
252 %
175 %
Prated
7.80 kW
7.00 kW
SCOP
6.49
4.57
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.86 kW
6.97 kW
COP Tj = +2°C
5.90
3.49
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
7.98 kW
7.31 kW
COP Tj = +7°C
6.30
4.13
Cdh Tj = +7 °C
0.994
0.996
Pdh Tj = 12°C
8.13 kW
7.75 kW
COP Tj = 12°C
6.90
5.29
Cdh Tj = +12 °C
0.994
0.995
Pdh Tj = Tbiv
7.86 kW
6.97 kW
COP Tj = Tbiv
5.90
3.49
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1606 kWh
2046 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
225 %
170 %
Prated
13.20 kW
12.30 kW
SCOP
5.83
4.45
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.13 kW
7.56 kW
COP Tj = -7°C
6.85
4.78
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
8.17 kW
7.74 kW
COP Tj = +2°C
7.04
5.28
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
8.22 kW
7.86 kW
COP Tj = +7°C
7.22
5.74
Cdh Tj = +7 °C
0.994
0.995
Pdh Tj = 12°C
8.22 kW
7.93 kW
COP Tj = 12°C
7.18
6.06
Cdh Tj = +12 °C
0.994
0.994
Pdh Tj = Tbiv
8.13 kW
7.56 kW
COP Tj = Tbiv
6.85
4.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.34 kW
5.33 kW
Annual energy consumption Qhe
5579 kWh
6815 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
250 %
176 %
Prated
8.90 kW
8.10 kW
SCOP
6.45
4.60
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.93 kW
7.17 kW
COP Tj = -7°C
6.11
3.81
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
8.02 kW
7.49 kW
COP Tj = +2°C
6.45
4.59
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
8.11 kW
7.68 kW
COP Tj = +7°C
6.81
5.13
Cdh Tj = +7 °C
0.994
0.995
Pdh Tj = 12°C
8.21 kW
7.87 kW
COP Tj = 12°C
7.19
5.75
Cdh Tj = +12 °C
0.994
0.995
Pdh Tj = Tbiv
7.93 kW
7.17 kW
COP Tj = Tbiv
6.11
3.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.04 kW
1.13 kW
Annual energy consumption Qhe
2852 kWh
3634 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2,04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2,04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2,04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.75 kW
5.12 kW
El input
1.32 kW
1.91 kW
COP
4.36
2.68
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
126 %
Prated
5.70 kW
5.10 kW
SCOP
4.66
3.36
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.75 kW
5.12 kW
COP Tj = +2°C
4.36
2.68
Cdh Tj = +2 °C
0.990
0.993
Pdh Tj = +7°C
5.82 kW
5.28 kW
COP Tj = +7°C
4.60
3.12
Cdh Tj = +7 °C
0.989
0.992
Pdh Tj = 12°C
5.92 kW
5.52 kW
COP Tj = 12°C
4.99
3.85
Cdh Tj = +12 °C
0.989
0.990
Pdh Tj = Tbiv
5.75 kW
5.12 kW
COP Tj = Tbiv
4.36
2.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.36
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1633 kWh
2027 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
127 %
Prated
9.60 kW
8.80 kW
SCOP
4.43
3.37
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.89 kW
5.39 kW
COP Tj = -7°C
4.94
3.47
Cdh Tj = -7 °C
0.989
0.991
Pdh Tj = +2°C
5.94 kW
5.51 kW
COP Tj = +2°C
5.08
3.83
Cdh Tj = +2 °C
0.988
0.990
Pdh Tj = +7°C
5.98 kW
5.61 kW
COP Tj = +7°C
5.22
4.12
Cdh Tj = +7 °C
0.988
0.990
Pdh Tj = 12°C
5.96 kW
5.68 kW
COP Tj = 12°C
5.19
4.36
Cdh Tj = +12 °C
0.988
0.989
Pdh Tj = Tbiv
5.89 kW
5.39 kW
COP Tj = Tbiv
4.94
3.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.36
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.85 kW
3.68 kW
Annual energy consumption Qhe
5345 kWh
6441 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
6.50 kW
5.90 kW
SCOP
4.72
3.39
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.77 kW
5.20 kW
COP Tj = -7°C
4.51
2.89
Cdh Tj = -7 °C
0.989
0.992
Pdh Tj = +2°C
5.83 kW
5.37 kW
COP Tj = +2°C
4.74
3.40
Cdh Tj = +2 °C
0.989
0.991
Pdh Tj = +7°C
5.89 kW
5.49 kW
COP Tj = +7°C
4.99
3.75
Cdh Tj = +7 °C
0.989
0.990
Pdh Tj = 12°C
5.96 kW
5.60 kW
COP Tj = 12°C
5.25
4.13
Cdh Tj = +12 °C
0.988
0.990
Pdh Tj = Tbiv
5.77 kW
5.20 kW
COP Tj = Tbiv
4.51
2.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.75 kW
5.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.43
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.993
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
0.78 kW
Annual energy consumption Qhe
2847 kWh
3592 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2:04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2:04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2:04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.86 kW
6.97 kW
El input
1.33 kW
2.00 kW
COP
5.90
3.49
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
252 %
175 %
Prated
7.80 kW
7.00 kW
SCOP
6.49
4.57
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.86 kW
6.97 kW
COP Tj = +2°C
5.90
3.49
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
7.98 kW
7.31 kW
COP Tj = +7°C
6.30
4.13
Cdh Tj = +7 °C
0.994
0.996
Pdh Tj = 12°C
8.13 kW
7.75 kW
COP Tj = 12°C
6.90
5.29
Cdh Tj = +12 °C
0.994
0.995
Pdh Tj = Tbiv
7.86 kW
6.97 kW
COP Tj = Tbiv
5.90
3.49
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1606 kWh
2046 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
225 %
170 %
Prated
13.20 kW
12.30 kW
SCOP
5.83
4.45
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
8.13 kW
7.56 kW
COP Tj = -7°C
6.85
4.78
Cdh Tj = -7 °C
0.994
0.995
Pdh Tj = +2°C
8.17 kW
7.74 kW
COP Tj = +2°C
7.04
5.28
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
8.22 kW
7.86 kW
COP Tj = +7°C
7.22
5.74
Cdh Tj = +7 °C
0.994
0.995
Pdh Tj = 12°C
8.22 kW
7.93 kW
COP Tj = 12°C
7.18
6.06
Cdh Tj = +12 °C
0.994
0.994
Pdh Tj = Tbiv
8.13 kW
7.56 kW
COP Tj = Tbiv
6.85
4.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.34 kW
5.33 kW
Annual energy consumption Qhe
5579 kWh
6815 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
250 %
176 %
Prated
8.90 kW
8.10 kW
SCOP
6.45
4.60
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.93 kW
7.17 kW
COP Tj = -7°C
6.11
3.81
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
8.02 kW
7.49 kW
COP Tj = +2°C
6.45
4.59
Cdh Tj = +2 °C
0.994
0.995
Pdh Tj = +7°C
8.11 kW
7.68 kW
COP Tj = +7°C
6.81
5.13
Cdh Tj = +7 °C
0.994
0.995
Pdh Tj = 12°C
8.21 kW
7.87 kW
COP Tj = 12°C
7.19
5.75
Cdh Tj = +12 °C
0.994
0.995
Pdh Tj = Tbiv
7.93 kW
7.17 kW
COP Tj = Tbiv
6.11
3.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.86 kW
6.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.90
3.49
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.04 kW
1.13 kW
Annual energy consumption Qhe
2852 kWh
3634 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2,04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2,04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
115 %
COP
2.80
Heating up time
2,04 h:min
Standby power input
26.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
289 l