Login

Subtype

VWL 37/5 230V / VWL 37/5 230V S2 / VWL 39/5 230V / VWL 39/5 230V S2 / VWL 57/5 230V, VWL 57/5 230V S2, VWL 59/5 230V / VWL 59/5 230V S2

Certificate Holder
Vaillant Deutschland GmbH & Co KG
Berghauser Straße 40
42859 Remscheid
Germany
Registration number
011-1W0754
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
VWL 37/5 230V / VWL 37/5 230V S2 / VWL 39/5 230V / VWL 39/5 230V S2 / VWL 57/5 230V, VWL 57/5 230V S2, VWL 59/5 230V / VWL 59/5 230V S2
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,400 kg

Certification Date
10.08.2022
Testing basis
DIN EN 14511-1:2019-07; EN 14511-1:2018, DIN EN 14511-2:2019-07; EN 14511-2:2018, DIN EN 14511-3:2019-07; EN 14511-3:2018, DIN EN 14511-4:2019-07; EN 14511-4:2018, DIN EN 14825:2019-07; EN 14825:2018, DIN EN 12102-1:2018-02; EN 12102-1:2017
Generate PDF Export model CSV
  • Number of models 8

Models

VWL 37/5 230V
Configure model
Model name
VWL 37/5 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.92 kW

4.73 kW

El input

1.15 kW

1.79 kW

COP

4.46

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

139 %

Prated

3.90 kW

3.80 kW

SCOP

5.38

3.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.93 kW

3.83 kW

COP Tj = +2°C

3.68

2.44

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.51 kW

2.44 kW

COP Tj = +7°C

5.29

3.31

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.70 kW

2.46 kW

COP Tj = 12°C

7.43

5.48

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.93 kW

3.80 kW

COP Tj = Tbiv

3.68

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.93 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

969 kWh

1428 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

109 %

Prated

3.85 kW

3.01 kW

SCOP

3.96

2.79

Tbiv

-13 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

2.43 kW

1.89 kW

COP Tj = -7°C

3.49

2.42

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.98 kW

1.75 kW

COP Tj = +2°C

4.79

3.46

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.31 kW

2.12 kW

COP Tj = +7°C

6.16

4.69

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.74 kW

2.57 kW

COP Tj = 12°C

7.83

6.54

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

2.99 kW

2.49 kW

COP Tj = Tbiv

2.77

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.36 kW

2.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.23

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.85 kW

3.01 kW

Annual energy consumption Qhe

2394 kWh

2661 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

130 %

Prated

4.00 kW

3.60 kW

SCOP

4.64

3.31

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.60 kW

3.24 kW

COP Tj = -7°C

3.15

2.11

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.31 kW

2.04 kW

COP Tj = +2°C

4.53

3.21

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.27 kW

2.06 kW

COP Tj = +7°C

5.84

4.30

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.75 kW

2.53 kW

COP Tj = 12°C

7.88

6.18

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.60 kW

3.24 kW

COP Tj = Tbiv

3.15

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.32 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.68 kW

0.74 kW

Annual energy consumption Qhe

1781 kWh

2246 kWh

VWL 39/5 230V
Configure model
Model name
VWL 39/5 230V
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.92 kW

4.73 kW

El input

1.15 kW

1.79 kW

COP

4.46

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

139 %

Prated

3.90 kW

3.80 kW

SCOP

5.38

3.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.93 kW

3.83 kW

COP Tj = +2°C

3.68

2.44

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.51 kW

2.44 kW

COP Tj = +7°C

5.29

3.31

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.70 kW

2.46 kW

COP Tj = 12°C

7.43

5.48

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.93 kW

3.80 kW

COP Tj = Tbiv

3.68

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.93 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

969 kWh

1428 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

109 %

Prated

3.85 kW

3.01 kW

SCOP

3.96

2.79

Tbiv

-13 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

2.43 kW

1.89 kW

COP Tj = -7°C

3.49

2.42

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.98 kW

1.75 kW

COP Tj = +2°C

4.79

3.46

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.31 kW

2.12 kW

COP Tj = +7°C

6.16

4.69

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.74 kW

2.57 kW

COP Tj = 12°C

7.83

6.54

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

2.99 kW

2.49 kW

COP Tj = Tbiv

2.77

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.36 kW

2.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.23

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.85 kW

3.01 kW

Annual energy consumption Qhe

2394 kWh

2661 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

130 %

Prated

4.00 kW

3.60 kW

SCOP

4.64

3.31

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.60 kW

3.24 kW

COP Tj = -7°C

3.15

2.11

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.31 kW

2.04 kW

COP Tj = +2°C

4.53

3.21

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.27 kW

2.06 kW

COP Tj = +7°C

5.84

4.30

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.75 kW

2.53 kW

COP Tj = 12°C

7.88

6.18

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.60 kW

3.24 kW

COP Tj = Tbiv

3.15

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.32 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.68 kW

0.74 kW

Annual energy consumption Qhe

1781 kWh

2246 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

02:42 h:min

Standby power input

19.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

275 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.22

Heating up time

04:39 h:min

Standby power input

21.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

265 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.51

Heating up time

03:49 h:min

Standby power input

20.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

276 l

VWL 37/5 230V S2
Configure model
Model name
VWL 37/5 230V S2
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.92 kW

4.73 kW

El input

1.15 kW

1.79 kW

COP

4.46

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

135 %

Prated

3.90 kW

3.80 kW

SCOP

5.13

3.44

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.93 kW

3.83 kW

COP Tj = +2°C

3.68

2.44

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.51 kW

2.44 kW

COP Tj = +7°C

5.29

3.31

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.70 kW

2.46 kW

COP Tj = 12°C

7.43

5.48

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.93 kW

3.80 kW

COP Tj = Tbiv

3.68

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.93 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1015 kWh

1477 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

108 %

Prated

3.85 kW

3.01 kW

SCOP

3.92

2.76

Tbiv

-13 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

2.43 kW

1.89 kW

COP Tj = -7°C

3.49

2.42

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.98 kW

1.75 kW

COP Tj = +2°C

4.79

3.46

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.31 kW

2.12 kW

COP Tj = +7°C

6.16

4.69

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.74 kW

2.57 kW

COP Tj = 12°C

7.83

6.54

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

2.99 kW

2.49 kW

COP Tj = Tbiv

2.77

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.36 kW

2.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.23

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.85 kW

3.01 kW

Annual energy consumption Qhe

2419 kWh

2686 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

127 %

Prated

4.00 kW

3.60 kW

SCOP

4.54

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.60 kW

3.24 kW

COP Tj = -7°C

3.15

2.11

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.31 kW

2.04 kW

COP Tj = +2°C

4.53

3.21

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.27 kW

2.06 kW

COP Tj = +7°C

5.84

4.30

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.75 kW

2.53 kW

COP Tj = 12°C

7.88

6.18

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.60 kW

3.24 kW

COP Tj = Tbiv

3.15

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.32 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.68 kW

0.74 kW

Annual energy consumption Qhe

1821 kWh

2286 kWh

VWL 39/5 230V S2
Configure model
Model name
VWL 39/5 230V S2
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.92 kW

4.73 kW

El input

1.15 kW

1.79 kW

COP

4.46

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

135 %

Prated

3.90 kW

3.80 kW

SCOP

5.13

3.44

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.93 kW

3.83 kW

COP Tj = +2°C

3.68

2.44

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.51 kW

2.44 kW

COP Tj = +7°C

5.29

3.31

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.70 kW

2.46 kW

COP Tj = 12°C

7.43

5.48

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.93 kW

3.80 kW

COP Tj = Tbiv

3.68

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.93 kW

3.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1015 kWh

1477 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

108 %

Prated

3.85 kW

3.01 kW

SCOP

3.92

2.76

Tbiv

-13 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

2.43 kW

1.89 kW

COP Tj = -7°C

3.49

2.42

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.98 kW

1.75 kW

COP Tj = +2°C

4.79

3.46

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.31 kW

2.12 kW

COP Tj = +7°C

6.16

4.69

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.74 kW

2.57 kW

COP Tj = 12°C

7.83

6.54

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

2.99 kW

2.49 kW

COP Tj = Tbiv

2.77

1.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.36 kW

2.49 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.23

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.85 kW

3.01 kW

Annual energy consumption Qhe

2419 kWh

2686 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

127 %

Prated

4.00 kW

3.60 kW

SCOP

4.54

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.60 kW

3.24 kW

COP Tj = -7°C

3.15

2.11

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.31 kW

2.04 kW

COP Tj = +2°C

4.53

3.21

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.27 kW

2.06 kW

COP Tj = +7°C

5.84

4.30

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.75 kW

2.53 kW

COP Tj = 12°C

7.88

6.18

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.60 kW

3.24 kW

COP Tj = Tbiv

3.15

2.11

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.32 kW

2.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.68 kW

0.74 kW

Annual energy consumption Qhe

1821 kWh

2286 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

02:42 h:min

Standby power input

19.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

275 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.22

Heating up time

04:39 h:min

Standby power input

21.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

265 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.51

Heating up time

03:49 h:min

Standby power input

20.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

276 l

VWL 57/5 230V
Configure model
Model name
VWL 57/5 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.92 kW

4.73 kW

El input

1.15 kW

1.79 kW

COP

4.46

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

161 %

Prated

3.90 kW

3.90 kW

SCOP

5.94

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.97 kW

3.83 kW

COP Tj = +2°C

3.68

2.44

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.48 kW

2.33 kW

COP Tj = +7°C

5.32

3.38

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.70 kW

2.46 kW

COP Tj = 12°C

7.43

5.48

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

3.97 kW

3.83 kW

COP Tj = Tbiv

3.68

2.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.97 kW

3.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

877 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

113 %

Prated

5.56 kW

4.69 kW

SCOP

3.79

2.90

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

3.25 kW

2.73 kW

COP Tj = -7°C

3.51

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.00 kW

1.77 kW

COP Tj = +2°C

4.93

3.57

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.35 kW

2.13 kW

COP Tj = +7°C

6.34

4.76

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.75 kW

2.57 kW

COP Tj = 12°C

7.88

6.54

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.58 kW

3.85 kW

COP Tj = Tbiv

2.56

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.58 kW

3.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.56 kW

4.69 kW

Annual energy consumption Qhe

3612 kWh

3989 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

135 %

Prated

6.40 kW

4.90 kW

SCOP

4.71

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.73 kW

4.38 kW

COP Tj = -7°C

2.93

2.12

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.55 kW

2.74 kW

COP Tj = +2°C

4.64

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.32 kW

2.08 kW

COP Tj = +7°C

6.10

4.40

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.77 kW

2.54 kW

COP Tj = 12°C

8.17

6.23

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

5.73 kW

4.38 kW

COP Tj = Tbiv

2.93

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.99 kW

3.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

0.99 kW

Annual energy consumption Qhe

2807 kWh

2941 kWh

VWL 59/5 230V
Configure model
Model name
VWL 59/5 230V
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.92 kW

4.73 kW

El input

1.15 kW

1.79 kW

COP

4.46

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

235 %

161 %

Prated

3.90 kW

3.90 kW

SCOP

5.94

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.97 kW

3.83 kW

COP Tj = +2°C

3.68

2.44

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.48 kW

2.33 kW

COP Tj = +7°C

5.32

3.38

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.70 kW

2.46 kW

COP Tj = 12°C

7.43

5.48

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

3.97 kW

3.83 kW

COP Tj = Tbiv

3.68

2.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.97 kW

3.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

877 kWh

1274 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

149 %

113 %

Prated

5.56 kW

4.69 kW

SCOP

3.79

2.90

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

3.25 kW

2.73 kW

COP Tj = -7°C

3.51

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.00 kW

1.77 kW

COP Tj = +2°C

4.93

3.57

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.35 kW

2.13 kW

COP Tj = +7°C

6.34

4.76

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.75 kW

2.57 kW

COP Tj = 12°C

7.88

6.54

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.58 kW

3.85 kW

COP Tj = Tbiv

2.56

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.58 kW

3.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.56 kW

4.69 kW

Annual energy consumption Qhe

3612 kWh

3989 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

135 %

Prated

6.40 kW

4.90 kW

SCOP

4.71

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.73 kW

4.38 kW

COP Tj = -7°C

2.93

2.12

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.55 kW

2.74 kW

COP Tj = +2°C

4.64

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.32 kW

2.08 kW

COP Tj = +7°C

6.10

4.40

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.77 kW

2.54 kW

COP Tj = 12°C

8.17

6.23

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

5.73 kW

4.38 kW

COP Tj = Tbiv

2.93

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.99 kW

3.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

0.99 kW

Annual energy consumption Qhe

2807 kWh

2941 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

02:42 h:min

Standby power input

19.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

275 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.22

Heating up time

04:39 h:min

Standby power input

21.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

265 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.51

Heating up time

03:49 h:min

Standby power input

20.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

276 l

VWL 57/5 230V S2
Configure model
Model name
VWL 57/5 230V S2
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.92 kW

4.73 kW

El input

1.15 kW

1.79 kW

COP

4.46

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

155 %

Prated

3.90 kW

3.90 kW

SCOP

5.63

3.96

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.97 kW

3.83 kW

COP Tj = +2°C

3.68

2.44

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.48 kW

2.33 kW

COP Tj = +7°C

5.32

3.38

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.70 kW

2.46 kW

COP Tj = 12°C

7.43

5.48

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

3.97 kW

3.83 kW

COP Tj = Tbiv

3.68

2.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.97 kW

3.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

925 kWh

1317 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

112 %

Prated

5.56 kW

4.69 kW

SCOP

3.77

2.88

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

3.25 kW

2.73 kW

COP Tj = -7°C

3.51

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.00 kW

1.77 kW

COP Tj = +2°C

4.93

3.57

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.35 kW

2.13 kW

COP Tj = +7°C

6.34

4.76

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.75 kW

2.57 kW

COP Tj = 12°C

7.88

6.54

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.58 kW

3.85 kW

COP Tj = Tbiv

2.56

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.58 kW

3.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.56 kW

4.69 kW

Annual energy consumption Qhe

3636 kWh

4013 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

133 %

Prated

6.40 kW

4.90 kW

SCOP

4.64

3.40

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.73 kW

4.38 kW

COP Tj = -7°C

2.93

2.12

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.55 kW

2.74 kW

COP Tj = +2°C

4.64

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.32 kW

2.08 kW

COP Tj = +7°C

6.10

4.40

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.77 kW

2.54 kW

COP Tj = 12°C

8.17

6.23

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

5.73 kW

4.38 kW

COP Tj = Tbiv

2.93

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.99 kW

3.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

0.99 kW

Annual energy consumption Qhe

2847 kWh

2982 kWh

VWL 59/5 230V S2
Configure model
Model name
VWL 59/5 230V S2
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.92 kW

4.73 kW

El input

1.15 kW

1.79 kW

COP

4.46

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

155 %

Prated

3.90 kW

3.90 kW

SCOP

5.63

3.96

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.97 kW

3.83 kW

COP Tj = +2°C

3.68

2.44

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.48 kW

2.33 kW

COP Tj = +7°C

5.32

3.38

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

2.70 kW

2.46 kW

COP Tj = 12°C

7.43

5.48

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

3.97 kW

3.83 kW

COP Tj = Tbiv

3.68

2.44

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.97 kW

3.83 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.68

2.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

925 kWh

1317 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

148 %

112 %

Prated

5.56 kW

4.69 kW

SCOP

3.77

2.88

Tbiv

-15 °C

-15 °C

TOL

-15 °C

-15 °C

Pdh Tj = -7°C

3.25 kW

2.73 kW

COP Tj = -7°C

3.51

2.55

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.00 kW

1.77 kW

COP Tj = +2°C

4.93

3.57

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.35 kW

2.13 kW

COP Tj = +7°C

6.34

4.76

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.75 kW

2.57 kW

COP Tj = 12°C

7.88

6.54

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.58 kW

3.85 kW

COP Tj = Tbiv

2.56

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.58 kW

3.85 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.56 kW

4.69 kW

Annual energy consumption Qhe

3636 kWh

4013 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

49 dB(A)

49 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

133 %

Prated

6.40 kW

4.90 kW

SCOP

4.64

3.40

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.73 kW

4.38 kW

COP Tj = -7°C

2.93

2.12

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.55 kW

2.74 kW

COP Tj = +2°C

4.64

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.32 kW

2.08 kW

COP Tj = +7°C

6.10

4.40

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.77 kW

2.54 kW

COP Tj = 12°C

8.17

6.23

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

5.73 kW

4.38 kW

COP Tj = Tbiv

2.93

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.99 kW

3.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.62

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

0.99 kW

Annual energy consumption Qhe

2847 kWh

2982 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

125 %

COP

3.06

Heating up time

02:42 h:min

Standby power input

19.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

275 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.22

Heating up time

04:39 h:min

Standby power input

21.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

265 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

102 %

COP

2.51

Heating up time

03:49 h:min

Standby power input

20.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

276 l