Login

Subtype

VWL 77/5 230V / VWL 77/5 230V S2 / VWL 79/5 230V / VWL 79/5 230V S2

Certificate Holder
Vaillant Deutschland GmbH & Co KG
Berghauser Straße 40
42859 Remscheid
Germany
Registration number
011-1W0755
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
VWL 77/5 230V / VWL 77/5 230V S2 / VWL 79/5 230V / VWL 79/5 230V S2
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,800 kg

Certification Date
10.08.2022
Testing basis
DIN EN 14511-1:2019-07; EN 14511-1:2018, DIN EN 14511-2:2019-07; EN 14511-2:2018, DIN EN 14511-3:2019-07; EN 14511-3:2018, DIN EN 14511-4:2019-07; EN 14511-4:2018, DIN EN 14825:2019-07; EN 14825:2018, DIN EN 12102-1:2018-02; EN 12102-1:2017
Generate PDF Export model CSV
  • Number of models 4

Models

VWL 77/5 230V
Configure model
Model name
VWL 77/5 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.77 kW

6.84 kW

El input

1.55 kW

2.60 kW

COP

3.72

2.63

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

47 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

221 %

154 %

Prated

4.45 kW

4.33 kW

SCOP

5.59

3.92

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.49 kW

4.36 kW

COP Tj = +2°C

3.63

2.45

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.82 kW

2.77 kW

COP Tj = +7°C

5.09

3.26

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

3.33 kW

3.14 kW

COP Tj = 12°C

6.87

5.30

Cdh Tj = +12 °C

0.969

0.965

Pdh Tj = Tbiv

4.49 kW

4.36 kW

COP Tj = Tbiv

3.63

2.45

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.49 kW

4.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.63

2.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1073 kWh

1474 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

47 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

114 %

Prated

6.25 kW

6.08 kW

SCOP

4.00

2.94

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

3.59 kW

3.81 kW

COP Tj = -7°C

3.38

2.53

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.55 kW

2.29 kW

COP Tj = +2°C

5.03

3.70

Cdh Tj = +2 °C

0.971

1.000

Pdh Tj = +7°C

2.86 kW

2.69 kW

COP Tj = +7°C

5.87

4.69

Cdh Tj = +7 °C

0.969

0.964

Pdh Tj = 12°C

3.42 kW

3.26 kW

COP Tj = 12°C

7.42

6.39

Cdh Tj = +12 °C

0.967

0.959

Pdh Tj = Tbiv

5.14 kW

4.99 kW

COP Tj = Tbiv

2.36

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.81 kW

4.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.25 kW

6.08 kW

Annual energy consumption Qhe

3854 kWh

5106 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

47 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

133 %

Prated

7.34 kW

6.32 kW

SCOP

4.29

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.53 kW

5.62 kW

COP Tj = -7°C

2.63

1.98

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.84 kW

3.42 kW

COP Tj = +2°C

4.26

3.45

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.84 kW

2.64 kW

COP Tj = +7°C

5.67

4.29

Cdh Tj = +7 °C

0.970

0.966

Pdh Tj = 12°C

3.43 kW

3.22 kW

COP Tj = 12°C

7.48

6.01

Cdh Tj = +12 °C

0.967

0.961

Pdh Tj = Tbiv

6.53 kW

5.62 kW

COP Tj = Tbiv

2.63

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.96 kW

4.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.54

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.74 kW

Annual energy consumption Qhe

3538 kWh

3849 kWh

VWL 79/5 230V
Configure model
Model name
VWL 79/5 230V
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.77 kW

6.84 kW

El input

1.55 kW

2.60 kW

COP

3.72

2.63

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

50 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

221 %

154 %

Prated

4.45 kW

4.33 kW

SCOP

5.59

3.92

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.49 kW

4.36 kW

COP Tj = +2°C

3.63

2.45

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.82 kW

2.77 kW

COP Tj = +7°C

5.09

3.26

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

3.33 kW

3.14 kW

COP Tj = 12°C

6.87

5.30

Cdh Tj = +12 °C

0.969

0.965

Pdh Tj = Tbiv

4.49 kW

4.36 kW

COP Tj = Tbiv

3.63

2.45

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.49 kW

4.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.63

2.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1073 kWh

1474 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

50 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

114 %

Prated

6.25 kW

6.08 kW

SCOP

4.00

2.94

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

3.59 kW

3.81 kW

COP Tj = -7°C

3.38

2.53

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.55 kW

2.29 kW

COP Tj = +2°C

5.03

3.70

Cdh Tj = +2 °C

0.971

1.000

Pdh Tj = +7°C

2.86 kW

2.69 kW

COP Tj = +7°C

5.87

4.69

Cdh Tj = +7 °C

0.969

0.964

Pdh Tj = 12°C

3.42 kW

3.26 kW

COP Tj = 12°C

7.42

6.39

Cdh Tj = +12 °C

0.967

0.959

Pdh Tj = Tbiv

5.14 kW

4.99 kW

COP Tj = Tbiv

2.36

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.81 kW

4.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.25 kW

6.08 kW

Annual energy consumption Qhe

3854 kWh

5106 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

50 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

169 %

133 %

Prated

7.34 kW

6.32 kW

SCOP

4.29

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.53 kW

5.62 kW

COP Tj = -7°C

2.63

1.98

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.84 kW

3.42 kW

COP Tj = +2°C

4.26

3.45

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.84 kW

2.64 kW

COP Tj = +7°C

5.67

4.29

Cdh Tj = +7 °C

0.970

0.966

Pdh Tj = 12°C

3.43 kW

3.22 kW

COP Tj = 12°C

7.48

6.01

Cdh Tj = +12 °C

0.970

0.961

Pdh Tj = Tbiv

6.53 kW

5.62 kW

COP Tj = Tbiv

2.63

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.96 kW

4.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.54

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.74 kW

Annual energy consumption Qhe

3538 kWh

3849 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.75

Heating up time

01:15 h:min

Standby power input

34.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

275 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.19

Heating up time

02:51 h:min

Standby power input

39.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

266 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

96 %

COP

2.33

Heating up time

02:24 h:min

Standby power input

38.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

270 l

VWL 77/5 230V S2
Configure model
Model name
VWL 77/5 230V S2
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.77 kW

6.84 kW

El input

1.55 kW

2.60 kW

COP

3.72

2.63

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

47 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

149 %

Prated

4.49 kW

4.36 kW

SCOP

5.37

3.81

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.49 kW

4.36 kW

COP Tj = +2°C

3.63

2.45

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.82 kW

2.77 kW

COP Tj = +7°C

5.09

3.26

Cdh Tj = +7 °C

1.000

0.930

Pdh Tj = 12°C

3.33 kW

3.14 kW

COP Tj = 12°C

6.87

5.30

Cdh Tj = +12 °C

0.969

0.965

Pdh Tj = Tbiv

4.49 kW

4.36 kW

COP Tj = Tbiv

3.63

2.45

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.49 kW

4.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.63

2.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1107 kWh

1519 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

47 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

114 %

Prated

6.25 kW

6.08 kW

SCOP

3.98

2.92

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

3.59 kW

3.81 kW

COP Tj = -7°C

3.38

2.53

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.55 kW

2.29 kW

COP Tj = +2°C

5.03

3.70

Cdh Tj = +2 °C

0.971

1.000

Pdh Tj = +7°C

2.86 kW

2.69 kW

COP Tj = +7°C

5.87

4.69

Cdh Tj = +7 °C

0.969

0.964

Pdh Tj = 12°C

3.42 kW

3.26 kW

COP Tj = 12°C

7.42

6.39

Cdh Tj = +12 °C

0.967

0.959

Pdh Tj = Tbiv

5.14 kW

4.99 kW

COP Tj = Tbiv

2.36

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.81 kW

4.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.25 kW

6.08 kW

Annual energy consumption Qhe

3875 kWh

5129 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

47 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

131 %

Prated

7.34 kW

6.32 kW

SCOP

4.24

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.52 kW

5.62 kW

COP Tj = -7°C

2.63

1.98

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.84 kW

3.42 kW

COP Tj = +2°C

4.26

3.45

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.84 kW

2.64 kW

COP Tj = +7°C

5.67

4.29

Cdh Tj = +7 °C

0.970

0.966

Pdh Tj = 12°C

3.43 kW

3.22 kW

COP Tj = 12°C

7.48

6.01

Cdh Tj = +12 °C

0.967

0.961

Pdh Tj = Tbiv

6.53 kW

5.62 kW

COP Tj = Tbiv

2.63

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.96 kW

4.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.54

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.74 kW

Annual energy consumption Qhe

3574 kWh

3887 kWh

VWL 79/5 230V S2
Configure model
Model name
VWL 79/5 230V S2
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.77 kW

6.84 kW

El input

1.55 kW

2.60 kW

COP

3.72

2.63

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

50 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

149 %

Prated

4.49 kW

4.36 kW

SCOP

5.37

3.81

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

4.49 kW

4.36 kW

COP Tj = +2°C

3.63

2.45

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.82 kW

2.77 kW

COP Tj = +7°C

5.09

3.26

Cdh Tj = +7 °C

1.000

0.930

Pdh Tj = 12°C

3.33 kW

3.14 kW

COP Tj = 12°C

6.87

5.30

Cdh Tj = +12 °C

0.969

0.965

Pdh Tj = Tbiv

4.49 kW

4.36 kW

COP Tj = Tbiv

3.63

2.45

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.49 kW

4.36 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.63

2.45

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1107 kWh

1519 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

50 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

114 %

Prated

6.25 kW

6.08 kW

SCOP

3.98

2.92

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

3.59 kW

3.81 kW

COP Tj = -7°C

3.38

2.53

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

2.55 kW

2.29 kW

COP Tj = +2°C

5.03

3.70

Cdh Tj = +2 °C

0.971

1.000

Pdh Tj = +7°C

2.86 kW

2.69 kW

COP Tj = +7°C

5.87

4.69

Cdh Tj = +7 °C

0.969

0.964

Pdh Tj = 12°C

3.42 kW

3.26 kW

COP Tj = 12°C

7.42

6.39

Cdh Tj = +12 °C

0.967

0.959

Pdh Tj = Tbiv

5.14 kW

4.99 kW

COP Tj = Tbiv

2.36

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.81 kW

4.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.25 kW

6.08 kW

Annual energy consumption Qhe

3875 kWh

5129 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

48 dB(A)

50 dB(A)

Sound power level outdoor

- dB(A)

- dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

131 %

Prated

7.34 kW

6.32 kW

SCOP

4.24

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.53 kW

5.62 kW

COP Tj = -7°C

2.63

1.98

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.84 kW

3.42 kW

COP Tj = +2°C

4.26

3.45

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

2.84 kW

2.64 kW

COP Tj = +7°C

5.67

4.29

Cdh Tj = +7 °C

0.970

0.966

Pdh Tj = 12°C

3.43 kW

3.22 kW

COP Tj = 12°C

7.48

6.01

Cdh Tj = +12 °C

0.967

0.961

Pdh Tj = Tbiv

6.53 kW

5.62 kW

COP Tj = Tbiv

2.63

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.96 kW

4.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.54

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.74 kW

Annual energy consumption Qhe

3574 kWh

3887 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

113 %

COP

2.75

Heating up time

01:15 h:min

Standby power input

34.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

275 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

90 %

COP

2.19

Heating up time

02:51 h:min

Standby power input

39.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

266 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

96 %

COP

2.33

Heating up time

02:24 h:min

Standby power input

38.0 W

Reference hot water temperature

55.0 °C

Mixed water at 40°C

270 l