1,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.14 kW
1.88 kW
El input
0.46 kW
0.72 kW
COP
4.68
2.60
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
161 %
Prated
5.30 kW
5.60 kW
SCOP
5.69
4.10
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.28 kW
5.65 kW
COP Tj = +2°C
3.08
2.22
Pdh Tj = +7°C
3.22 kW
3.92 kW
COP Tj = +7°C
5.31
3.54
Pdh Tj = 12°C
1.50 kW
2.49 kW
COP Tj = 12°C
6.79
5.35
Pdh Tj = Tbiv
5.28 kW
5.65 kW
COP Tj = Tbiv
3.08
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.28 kW
5.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.08
2.22
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1245 kWh
1823 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
159 %
117 %
Prated
3.90 kW
4.00 kW
SCOP
4.04
3.00
Tbiv
-17 °C
-16 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
2.46 kW
2.32 kW
COP Tj = -7°C
3.56
2.57
Pdh Tj = +2°C
1.48 kW
1.79 kW
COP Tj = +2°C
4.86
3.66
Pdh Tj = +7°C
1.13 kW
2.13 kW
COP Tj = +7°C
5.53
4.54
Pdh Tj = 12°C
1.21 kW
2.55 kW
COP Tj = 12°C
5.75
5.82
Pdh Tj = Tbiv
3.43 kW
3.37 kW
COP Tj = Tbiv
2.36
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.08 kW
3.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.61
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
4.00 kW
Annual energy consumption Qhe
2378 kWh
3287 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.27
1.88
COP Tj = -15°C (if TOL<-20°C)
2.55
1.88
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
131 %
Prated
4.40 kW
4.10 kW
SCOP
4.65
3.34
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.88 kW
3.57 kW
COP Tj = -7°C
3.07
2.16
Pdh Tj = +2°C
2.51 kW
2.34 kW
COP Tj = +2°C
4.69
3.29
Pdh Tj = +7°C
1.50 kW
2.13 kW
COP Tj = +7°C
5.78
4.29
Pdh Tj = 12°C
1.23 kW
2.52 kW
COP Tj = 12°C
6.13
5.53
Pdh Tj = Tbiv
4.37 kW
4.05 kW
COP Tj = Tbiv
2.76
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.37 kW
4.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.76
1.85
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1955 kWh
2533 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.14 kW
1.88 kW
El input
0.46 kW
0.72 kW
COP
4.68
2.60
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
161 %
Prated
5.30 kW
5.60 kW
SCOP
5.69
4.10
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.28 kW
5.65 kW
COP Tj = +2°C
3.08
2.22
Pdh Tj = +7°C
3.22 kW
3.92 kW
COP Tj = +7°C
5.31
3.54
Pdh Tj = 12°C
1.50 kW
2.49 kW
COP Tj = 12°C
6.79
5.35
Pdh Tj = Tbiv
5.28 kW
5.65 kW
COP Tj = Tbiv
3.08
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.28 kW
5.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.08
2.22
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1245 kWh
1823 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
159 %
117 %
Prated
3.90 kW
4.00 kW
SCOP
4.04
3.00
Tbiv
-17 °C
-16 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
2.46 kW
2.32 kW
COP Tj = -7°C
3.56
2.57
Cdh Tj = -7 °C
Pdh Tj = +2°C
1.48 kW
1.79 kW
COP Tj = +2°C
4.86
3.66
Cdh Tj = +2 °C
Pdh Tj = +7°C
1.13 kW
2.13 kW
COP Tj = +7°C
5.53
4.54
Cdh Tj = +7 °C
Pdh Tj = 12°C
1.21 kW
2.55 kW
COP Tj = 12°C
5.75
5.82
Cdh Tj = +12 °C
Pdh Tj = Tbiv
3.43 kW
3.37 kW
COP Tj = Tbiv
2.36
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.08 kW
3.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.61
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
3.90 kW
4.00 kW
Annual energy consumption Qhe
2378 kWh
3287 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.27
1.88
COP Tj = -15°C (if TOL<-20°C)
2.55
1.88
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
29 dB(A)
29 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
131 %
Prated
4.40 kW
4.10 kW
SCOP
4.65
3.34
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.88 kW
3.57 kW
COP Tj = -7°C
3.07
2.16
Pdh Tj = +2°C
2.51 kW
2.34 kW
COP Tj = +2°C
4.69
3.29
Pdh Tj = +7°C
1.50 kW
2.13 kW
COP Tj = +7°C
5.78
4.29
Pdh Tj = 12°C
1.23 kW
2.52 kW
COP Tj = 12°C
6.13
5.53
Pdh Tj = Tbiv
4.37 kW
4.05 kW
COP Tj = Tbiv
2.76
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.37 kW
4.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.76
1.85
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1955 kWh
2533 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.14 kW
1.88 kW
El input
0.46 kW
0.72 kW
COP
4.68
2.60
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
25 dB(A)
25 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
161 %
Prated
5.30 kW
5.60 kW
SCOP
5.69
4.10
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.28 kW
5.65 kW
COP Tj = +2°C
3.08
2.22
Pdh Tj = +7°C
3.22 kW
3.92 kW
COP Tj = +7°C
5.31
3.54
Pdh Tj = 12°C
1.50 kW
2.49 kW
COP Tj = 12°C
6.79
5.35
Pdh Tj = Tbiv
5.28 kW
5.65 kW
COP Tj = Tbiv
3.08
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.28 kW
5.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.08
2.22
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1245 kWh
1823 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
25 dB(A)
25 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
159 %
117 %
Prated
3.90 kW
4.00 kW
SCOP
4.04
3.00
Tbiv
-17 °C
-16 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
2.46 kW
2.32 kW
COP Tj = -7°C
3.56
2.57
Pdh Tj = +2°C
1.48 kW
1.79 kW
COP Tj = +2°C
4.86
3.66
Pdh Tj = +7°C
1.13 kW
2.13 kW
COP Tj = +7°C
5.53
4.54
Pdh Tj = 12°C
1.21 kW
2.55 kW
COP Tj = 12°C
5.75
5.82
Pdh Tj = Tbiv
3.43 kW
3.37 kW
COP Tj = Tbiv
2.36
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.08 kW
3.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.61
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
4.00 kW
Annual energy consumption Qhe
2378 kWh
3287 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.27
1.88
COP Tj = -15°C (if TOL<-20°C)
2.55
1.88
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
25 dB(A)
25 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
131 %
Prated
4.40 kW
4.10 kW
SCOP
4.65
3.34
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.88 kW
3.57 kW
COP Tj = -7°C
3.07
2.16
Pdh Tj = +2°C
2.51 kW
2.34 kW
COP Tj = +2°C
4.69
3.29
Pdh Tj = +7°C
1.50 kW
2.13 kW
COP Tj = +7°C
5.78
4.29
Pdh Tj = 12°C
1.23 kW
2.52 kW
COP Tj = 12°C
6.13
5.53
Pdh Tj = Tbiv
4.37 kW
4.05 kW
COP Tj = Tbiv
2.76
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.37 kW
4.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.76
1.85
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1955 kWh
2533 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
119 %
COP
2.80
Heating up time
03:00 h:min
Standby power input
47.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
272 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
81 %
COP
1.90
Heating up time
04:18 h:min
Standby power input
65.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
275 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
96 %
COP
2.25
Heating up time
03:30 h:min
Standby power input
55.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
272 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.14 kW
1.88 kW
El input
0.46 kW
0.72 kW
COP
4.68
2.60
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
25 dB(A)
25 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
224 %
161 %
Prated
5.30 kW
5.60 kW
SCOP
5.69
4.10
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.28 kW
5.65 kW
COP Tj = +2°C
3.08
2.22
Pdh Tj = +7°C
3.22 kW
3.92 kW
COP Tj = +7°C
5.31
3.54
Pdh Tj = 12°C
1.50 kW
2.49 kW
COP Tj = 12°C
6.79
5.35
Pdh Tj = Tbiv
5.28 kW
5.65 kW
COP Tj = Tbiv
3.08
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.28 kW
5.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.08
2.22
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1245 kWh
1823 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
25 dB(A)
25 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
159 %
117 %
Prated
3.90 kW
4.00 kW
SCOP
4.04
3.00
Tbiv
-17 °C
-16 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
2.46 kW
2.32 kW
COP Tj = -7°C
3.56
2.57
Pdh Tj = +2°C
1.48 kW
1.79 kW
COP Tj = +2°C
4.86
3.66
Pdh Tj = +7°C
1.13 kW
2.13 kW
COP Tj = +7°C
5.53
4.54
Pdh Tj = 12°C
1.21 kW
2.55 kW
COP Tj = 12°C
5.75
5.82
Pdh Tj = Tbiv
3.43 kW
3.37 kW
COP Tj = Tbiv
2.36
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.08 kW
3.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.16
1.61
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
4.00 kW
Annual energy consumption Qhe
2378 kWh
3287 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.27
1.88
COP Tj = -15°C (if TOL<-20°C)
2.55
1.88
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
25 dB(A)
25 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
131 %
Prated
4.40 kW
4.10 kW
SCOP
4.65
3.34
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.88 kW
3.57 kW
COP Tj = -7°C
3.07
2.16
Pdh Tj = +2°C
2.51 kW
2.34 kW
COP Tj = +2°C
4.69
3.29
Pdh Tj = +7°C
1.50 kW
2.13 kW
COP Tj = +7°C
5.78
4.29
Pdh Tj = 12°C
1.23 kW
2.52 kW
COP Tj = 12°C
6.13
5.53
Pdh Tj = Tbiv
4.37 kW
4.05 kW
COP Tj = Tbiv
2.76
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.37 kW
4.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.76
1.85
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
17 W
17 W
PTO
22 W
22 W
PSB
17 W
17 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1955 kWh
2533 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
119 %
COP
2.80
Heating up time
03:00 h:min
Standby power input
47.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
272 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
81 %
COP
1.90
Heating up time
04:18 h:min
Standby power input
65.0 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
275 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
96 %
COP
2.25
Heating up time
03:30 h:min
Standby power input
55.0 W
Reference hot water temperature
52.1 °C
Mixed water at 40°C
272 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.14 kW
1.88 kW
El input
0.48 kW
0.75 kW
COP
4.44
2.52
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
153 %
Prated
5.30 kW
5.60 kW
SCOP
5.28
3.90
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.28 kW
5.65 kW
COP Tj = +2°C
2.98
2.19
Pdh Tj = +7°C
3.22 kW
3.92 kW
COP Tj = +7°C
5.01
3.45
Pdh Tj = 12°C
1.50 kW
2.49 kW
COP Tj = 12°C
6.19
5.05
Pdh Tj = Tbiv
5.28 kW
5.65 kW
COP Tj = Tbiv
2.98
2.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.28 kW
5.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.98
2.19
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
4 W
4 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1341 kWh
1918 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
150 %
112 %
Prated
3.90 kW
4.00 kW
SCOP
3.83
2.87
Tbiv
-17 °C
-16 °C
TOL
-20 °C
-18 °C
Pdh Tj = -7°C
2.46 kW
2.32 kW
COP Tj = -7°C
3.43
2.52
Pdh Tj = +2°C
1.48 kW
1.79 kW
COP Tj = +2°C
4.59
3.51
Pdh Tj = +7°C
1.13 kW
2.13 kW
COP Tj = +7°C
5.13
4.33
Pdh Tj = 12°C
1.21 kW
2.55 kW
COP Tj = 12°C
5.24
5.51
Pdh Tj = Tbiv
3.43 kW
3.37 kW
COP Tj = Tbiv
2.31
1.76
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.08 kW
3.11 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.12
1.59
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
4 W
4 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.90 kW
4.00 kW
Annual energy consumption Qhe
2511 kWh
3430 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.27
3.29
COP Tj = -15°C (if TOL<-20°C)
2.49
1.85
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
49 dB(A)
49 dB(A)
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
172 %
125 %
Prated
4.40 kW
4.10 kW
SCOP
4.39
3.20
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.88 kW
3.57 kW
COP Tj = -7°C
2.99
2.13
Pdh Tj = +2°C
2.51 kW
2.34 kW
COP Tj = +2°C
4.50
3.20
Pdh Tj = +7°C
1.50 kW
2.13 kW
COP Tj = +7°C
5.32
4.08
Pdh Tj = 12°C
1.23 kW
2.52 kW
COP Tj = 12°C
5.57
5.22
Pdh Tj = Tbiv
4.37 kW
4.05 kW
COP Tj = Tbiv
2.70
1.83
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.37 kW
4.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.83
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
4 W
4 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2072 kWh
2647 kWh