Login

Subtype

Monobloc ACHP-H series 12/14/16

Certificate Holder
Ningbo AUX Electric Co., Ltd
1166 Mingguang North Road
315191 Ningbo Zhejiang
China
Registration number
011-1W0741
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Monobloc ACHP-H series 12/14/16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,350 kg

Certification Date
27.11.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Version 12 (2023-03)
Generate PDF Export model CSV
  • Number of models 12

Models

ACHP-H12/5R2HA-M
Configure model
Model name
ACHP-H12/5R2HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.45 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

12.20 kW

12.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.50

3.67

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.60

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.69 kW

4.12 kW

COP Tj = 12°C

9.38

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5314 kWh

6477 kWh

ACHP-H14/5R2HA-M
Configure model
Model name
ACHP-H14/5R2HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.38 kW

COP

4.80

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.52

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

6.40

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.68 kW

2.15 kW

COP Tj = 12°C

10.00

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6317 kWh

7563 kWh

ACHP-H16/5R2HA-M
Configure model
Model name
ACHP-H16/5R2HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.10 kW

15.10 kW

El input

3.21 kW

4.79 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

150 %

Prated

15.50 kW

14.00 kW

SCOP

4.77

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.38 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.35 kW

7.54 kW

COP Tj = +2°C

4.48

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.37 kW

4.85 kW

COP Tj = +7°C

6.73

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.38 kW

4.43 kW

COP Tj = 12°C

10.05

8.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.71 kW

12.38 kW

COP Tj = Tbiv

3.01

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.08 kW

3.50 kW

Annual energy consumption Qhe

6604 kWh

7563 kWh

ACHP-H12/5R2HA-M(NE)
Configure model
Model name
ACHP-H12/5R2HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.45 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

12.20 kW

12.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.50

3.67

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.60

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.69 kW

4.12 kW

COP Tj = 12°C

9.38

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5314 kWh

6477 kWh

ACHP-H14/5R2HA-M(NE)
Configure model
Model name
ACHP-H14/5R2HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.38 kW

COP

4.80

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.52

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

6.40

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.68 kW

2.15 kW

COP Tj = 12°C

10.00

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6317 kWh

7563 kWh

ACHP-H16/5R2HA-M(NE)
Configure model
Model name
ACHP-H16/5R2HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.10 kW

15.10 kW

El input

3.21 kW

4.79 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

150 %

Prated

15.50 kW

14.00 kW

SCOP

4.77

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.38 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.35 kW

7.54 kW

COP Tj = +2°C

4.48

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.37 kW

4.85 kW

COP Tj = +7°C

6.73

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.38 kW

4.43 kW

COP Tj = 12°C

10.05

8.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.71 kW

12.38 kW

COP Tj = Tbiv

3.01

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.08 kW

3.50 kW

Annual energy consumption Qhe

6604 kWh

7563 kWh

ACHP-H12/4R2HA-M
Configure model
Model name
ACHP-H12/4R2HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.45 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

12.20 kW

12.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.50

3.67

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.60

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.69 kW

4.12 kW

COP Tj = 12°C

9.38

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5314 kWh

6477 kWh

ACHP-H14/4R2HA-M
Configure model
Model name
ACHP-H14/4R2HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.38 kW

COP

4.80

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.52

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

6.40

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.68 kW

2.15 kW

COP Tj = 12°C

10.00

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6317 kWh

7563 kWh

ACHP-H16/4R2HA-M
Configure model
Model name
ACHP-H16/4R2HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.10 kW

15.10 kW

El input

3.21 kW

4.79 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

150 %

Prated

15.50 kW

14.00 kW

SCOP

4.77

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.38 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.35 kW

7.54 kW

COP Tj = +2°C

4.48

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.37 kW

4.85 kW

COP Tj = +7°C

6.73

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.38 kW

4.43 kW

COP Tj = 12°C

10.05

8.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.71 kW

12.38 kW

COP Tj = Tbiv

3.01

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.08 kW

3.50 kW

Annual energy consumption Qhe

6604 kWh

7563 kWh

ACHP-H12/4R2HA-M(NE)
Configure model
Model name
ACHP-H12/4R2HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.45 kW

3.69 kW

COP

4.90

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

12.20 kW

12.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.79 kW

10.62 kW

COP Tj = -7°C

3.02

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.57 kW

6.46 kW

COP Tj = +2°C

4.50

3.67

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.22 kW

4.15 kW

COP Tj = +7°C

6.60

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.69 kW

4.12 kW

COP Tj = 12°C

9.38

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.79 kW

10.62 kW

COP Tj = Tbiv

3.02

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.10 kW

9.16 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.10 kW

2.84 kW

Annual energy consumption Qhe

5314 kWh

6477 kWh

ACHP-H14/4R2HA-M(NE)
Configure model
Model name
ACHP-H14/4R2HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

2.92 kW

4.38 kW

COP

4.80

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

150 %

Prated

14.50 kW

14.00 kW

SCOP

4.72

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.83 kW

12.38 kW

COP Tj = -7°C

3.00

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.81 kW

7.54 kW

COP Tj = +2°C

4.52

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.02 kW

4.85 kW

COP Tj = +7°C

6.40

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.68 kW

2.15 kW

COP Tj = 12°C

10.00

7.60

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.83 kW

12.38 kW

COP Tj = Tbiv

3.00

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.46 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.04 kW

3.50 kW

Annual energy consumption Qhe

6317 kWh

7563 kWh

ACHP-H16/4R2HA-M(NE)
Configure model
Model name
ACHP-H16/4R2HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.10 kW

15.10 kW

El input

3.21 kW

4.79 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

150 %

Prated

15.50 kW

14.00 kW

SCOP

4.77

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.38 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.35 kW

7.54 kW

COP Tj = +2°C

4.48

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.37 kW

4.85 kW

COP Tj = +7°C

6.73

5.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.38 kW

4.43 kW

COP Tj = 12°C

10.05

8.75

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.71 kW

12.38 kW

COP Tj = Tbiv

3.01

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

10.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

2.13

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.08 kW

3.50 kW

Annual energy consumption Qhe

6604 kWh

7563 kWh