Login

Subtype

Wall-mounted heat pump water heater-150L-B1

Certificate Holder
GD Midea Air-Conditioning Equipment Co., Ltd.
Lingang Road,
Guangdong
China
Registration number
011-1W0768
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Wall-mounted heat pump water heater-150L-B1
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R290
Mass of Refrigerant

0,150 kg

Certification Date
25.01.2024
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 12 (as of 2023-03)
Generate PDF Export model CSV
  • Number of models 2

Models

EU-RSJ-09/150RDN7-B1
Configure model
Model name
EU-RSJ-09/150RDN7-B1
Units
Indoor
Climate zone (for heating)
Colder + Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

137 %

COP

3.02

Heating up time

6:10 h:min

Standby power input

22.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

155 l

Colder Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.49

Heating up time

7:10 h:min

Standby power input

24.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

158 l

Average Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

122 %

COP

2.67

Heating up time

6:32 h:min

Standby power input

23.0 W

Reference hot water temperature

51.9 °C

Mixed water at 40°C

160 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

RSJ-09/150RDN7-B1
Configure model
Model name
RSJ-09/150RDN7-B1
Units
Indoor
Climate zone (for heating)
Colder + Warmer
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Warmer Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

137 %

COP

3.02

Heating up time

6:10 h:min

Standby power input

22.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

155 l

Colder Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

103 %

COP

2.49

Heating up time

7:10 h:min

Standby power input

24.0 W

Reference hot water temperature

52.1 °C

Mixed water at 40°C

158 l

Average Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

122 %

COP

2.67

Heating up time

6:32 h:min

Standby power input

23.0 W

Reference hot water temperature

51.9 °C

Mixed water at 40°C

160 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed