Login

Subtype

M thermal N series 12 14 16 kW

Certificate Holder
GD Midea Heating & Ventilating Equipment Co., Ltd.
Penglai Industry Road
528311 Beijiao, Shunde, Foshan
China
Registration number
ICIM-PDC-000226
Certification Body
ICIM S.p.A.
Subtype title
M thermal N series 12 14 16 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,100 kg

Certification Date
19.03.2024
Testing basis
V12
Generate PDF Export model CSV Download certificate
  • Number of models 6

Models

MHC-V12WD2N7-B***
Configure model
Model name
MHC-V12WD2N7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

11.9 kW

El input

2.44 kW

3.66 kW

COP

4.95

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

155 %

Prated

12.1 kW

12.1 kW

SCOP

4.93

3.95

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

10.70 kW

10.70 kW

COP Tj = -7°C

2.89

2.52

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.51 kW

6.74 kW

COP Tj = +2°C

4.71

3.83

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

5.46 kW

5.32 kW

COP Tj = +7°C

7.04

5.25

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

6.30 kW

5.94 kW

COP Tj = 12°C

8.64

6.46

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

10.70 kW

10.70 kW

COP Tj = Tbiv

2.89

2.52

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.72 kW

11.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

2.01

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.38 kW

0.83 kW

Annual energy consumption Qhe

5064 kWh

6312 kWh

MHC-V14WD2N7-B***
Configure model
Model name
MHC-V14WD2N7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.0 kW

13.8 kW

El input

2.98 kW

4.38 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

151 %

Prated

14.1 kW

13.8 kW

SCOP

4.75

3.85

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

12.47 kW

12.21 kW

COP Tj = -7°C

2.63

2.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

7.60 kW

7.51 kW

COP Tj = +2°C

4.52

3.71

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

5.49 kW

5.15 kW

COP Tj = +7°C

7.16

5.39

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

6.30 kW

6.13 kW

COP Tj = 12°C

8.66

6.84

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.47 kW

12.21 kW

COP Tj = Tbiv

2.63

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.63 kW

12.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

1.97

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.47 kW

1.55 kW

Annual energy consumption Qhe

6118 kWh

7405 kWh

MHC-V16WD2N7-B***
Configure model
Model name
MHC-V16WD2N7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.5 kW

16.0 kW

El input

3.44 kW

5.25 kW

COP

4.50

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

151 %

Prated

15.9 kW

14.7 kW

SCOP

4.70

3.85

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

14.07 kW

13.00 kW

COP Tj = -7°C

2.45

2.33

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

8.54 kW

7.96 kW

COP Tj = +2°C

4.53

3.68

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

5.50 kW

5.34 kW

COP Tj = +7°C

7.25

5.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

6.27 kW

5.98 kW

COP Tj = 12°C

8.80

6.58

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14.07 kW

13.00 kW

COP Tj = Tbiv

2.45

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

13.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.95

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.48 kW

1.31 kW

Annual energy consumption Qhe

6966 kWh

7862 kWh

MHC-V12WD2RN7-B***
Configure model
Model name
MHC-V12WD2RN7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

11.9 kW

El input

2.44 kW

3.66 kW

COP

4.95

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

155 %

Prated

12.1 kW

12.1 kW

SCOP

4.93

3.95

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

10.70 kW

10.70 kW

COP Tj = -7°C

2.89

2.52

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.51 kW

6.74 kW

COP Tj = +2°C

4.71

3.83

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

5.46 kW

5.32 kW

COP Tj = +7°C

7.04

5.25

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

6.30 kW

5.94 kW

COP Tj = 12°C

8.64

6.46

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

10.70 kW

10.70 kW

COP Tj = Tbiv

2.89

2.52

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.72 kW

11.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

2.01

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.38 kW

0.83 kW

Annual energy consumption Qhe

5064 kWh

6312 kWh

MHC-V14WD2RN7-B***
Configure model
Model name
MHC-V14WD2RN7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.0 kW

13.8 kW

El input

2.98 kW

4.38 kW

COP

4.70

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

151 %

Prated

14.1 kW

13.8 kW

SCOP

4.75

3.85

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

12.47 kW

12.21 kW

COP Tj = -7°C

2.63

2.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

7.60 kW

7.51 kW

COP Tj = +2°C

4.52

3.71

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

5.49 kW

5.15 kW

COP Tj = +7°C

7.16

5.39

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

6.30 kW

6.13 kW

COP Tj = 12°C

8.66

6.84

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.47 kW

12.21 kW

COP Tj = Tbiv

2.63

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.63 kW

12.25 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

1.97

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.47 kW

1.55 kW

Annual energy consumption Qhe

6118 kWh

7405 kWh

MHC-V16WD2RN7-B***
Configure model
Model name
MHC-V16WD2RN7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.5 kW

16.0 kW

El input

3.44 kW

5.25 kW

COP

4.50

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

151 %

Prated

15.9 kW

14.7 kW

SCOP

4.70

3.85

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

14.07 kW

13.00 kW

COP Tj = -7°C

2.45

2.33

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

8.54 kW

7.96 kW

COP Tj = +2°C

4.53

3.68

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

5.50 kW

5.34 kW

COP Tj = +7°C

7.25

5.40

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

6.27 kW

5.98 kW

COP Tj = 12°C

8.80

6.58

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

14.07 kW

13.00 kW

COP Tj = Tbiv

2.45

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.42 kW

13.39 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.43

1.95

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.48 kW

1.31 kW

Annual energy consumption Qhe

6966 kWh

7862 kWh