Login

Subtype

M thermal N series 8 10 kW

Certificate Holder
GD Midea Heating & Ventilating Equipment Co., Ltd.
Penglai Industry Road
528311 Beijiao, Shunde, Foshan
China
Registration number
ICIM-PDC-000225
Certification Body
ICIM S.p.A.
Subtype title
M thermal N series 8 10 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,100 kg

Certification Date
19.03.2024
Testing basis
V12
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

MHC-V8WD2N7-B***
Configure model
Model name
MHC-V8WD2N7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.0 kW

8.0 kW

El input

1.52 kW

2.39 kW

COP

5.25

3.35

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

159 %

Prated

7.9 kW

8.2 kW

SCOP

5.35

4.05

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

6.99 kW

7.26 kW

COP Tj = -7°C

3.30

2.46

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.51 kW

4.51 kW

COP Tj = +2°C

5.30

4.02

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.88 kW

3.72 kW

COP Tj = +7°C

6.87

5.27

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

4.52 kW

4.40 kW

COP Tj = 12°C

9.03

6.90

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

6.99 kW

7.26 kW

COP Tj = Tbiv

3.30

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

8.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.11

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3051 kWh

4168 kWh

MHC-V10WD2N7-B***
Configure model
Model name
MHC-V10WD2N7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.5 kW

9.5 kW

El input

1.92 kW

2.97 kW

COP

4.95

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

157 %

Prated

9.8 kW

10.0 kW

SCOP

5.33

4.00

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

8.67 kW

8.85 kW

COP Tj = -7°C

3.19

2.23

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

5.50 kW

5.48 kW

COP Tj = +2°C

5.19

3.98

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.93 kW

3.78 kW

COP Tj = +7°C

7.17

5.48

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

4.53 kW

4.43 kW

COP Tj = 12°C

9.12

7.03

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

8.67 kW

8.85 kW

COP Tj = Tbiv

3.19

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.75 kW

8.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

2.06

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

1.02 kW

Annual energy consumption Qhe

3802 kWh

5148 kWh

MHC-V8WD2RN7-B***
Configure model
Model name
MHC-V8WD2RN7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.0 kW

8.0 kW

El input

1.52 kW

2.39 kW

COP

5.25

3.35

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

159 %

Prated

7.9 kW

8.2 kW

SCOP

5.35

4.05

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

6.99 kW

7.26 kW

COP Tj = -7°C

3.30

2.46

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.51 kW

4.51 kW

COP Tj = +2°C

5.30

4.02

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.88 kW

3.72 kW

COP Tj = +7°C

6.87

5.27

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

4.52 kW

4.40 kW

COP Tj = 12°C

9.03

6.90

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

6.99 kW

7.26 kW

COP Tj = Tbiv

3.30

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.90 kW

8.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

2.11

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3051 kWh

4168 kWh

MHC-V10WD2RN7-B***
Configure model
Model name
MHC-V10WD2RN7-B***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.5 kW

9.5 kW

El input

1.92 kW

2.97 kW

COP

4.95

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

157 %

Prated

9.8 kW

10.0 kW

SCOP

5.33

4.00

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

8.67 kW

8.85 kW

COP Tj = -7°C

3.19

2.23

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

5.50 kW

5.48 kW

COP Tj = +2°C

5.19

3.98

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.93 kW

3.78 kW

COP Tj = +7°C

7.17

5.48

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

4.53 kW

4.43 kW

COP Tj = 12°C

9.12

7.03

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

8.67 kW

8.85 kW

COP Tj = Tbiv

3.19

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.75 kW

8.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.65

2.06

WTOL

80.00 °C

80.00 °C

Poff

11.00 W

11.00 W

PTO

16.00 W

16.00 W

PSB

11.00 W

11.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

1.02 kW

Annual energy consumption Qhe

3802 kWh

5148 kWh