Login

Subtype

Monobloc ACHP-H series 04/06

Certificate Holder
Ningbo AUX Electric Co., Ltd
1166 Mingguang North Road
315191 Ningbo Zhejiang
China
Registration number
011-1W0739
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Monobloc ACHP-H series 04/06
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,550 kg

Certification Date
27.11.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Version 12 (2023-03)
Generate PDF Export model CSV
  • Number of models 4

Models

ACHP-H04/4R2HA-M
Configure model
Model name
ACHP-H04/4R2HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.50 kW

4.60 kW

El input

0.87 kW

1.44 kW

COP

5.15

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

5.50 kW

5.50 kW

SCOP

4.95

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.87 kW

4.87 kW

COP Tj = -7°C

2.96

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.96 kW

2.96 kW

COP Tj = +2°C

4.84

3.75

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.90 kW

1.90 kW

COP Tj = +7°C

6.46

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.02 kW

2.16 kW

COP Tj = 12°C

11.71

7.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.87 kW

4.87 kW

COP Tj = Tbiv

2.96

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.16 kW

0.00 kW

Annual energy consumption Qhe

2295 kWh

2950 kWh

ACHP-H06/4R2HA-M
Configure model
Model name
ACHP-H06/4R2HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.35 kW

6.40 kW

El input

1.27 kW

1.97 kW

COP

5.00

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

151 %

Prated

6.80 kW

6.30 kW

SCOP

4.92

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

5.57 kW

COP Tj = -7°C

2.85

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.66 kW

3.39 kW

COP Tj = +2°C

4.98

3.72

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.35 kW

2.18 kW

COP Tj = +7°C

6.38

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.17 kW

2.07 kW

COP Tj = 12°C

9.67

7.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.02 kW

5.57 kW

COP Tj = Tbiv

2.85

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.42 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

0.30 kW

Annual energy consumption Qhe

2818 kWh

3381 kWh

ACHP-H04/4R2HA-M(NE)
Configure model
Model name
ACHP-H04/4R2HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.50 kW

4.60 kW

El input

0.87 kW

1.44 kW

COP

5.15

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

151 %

Prated

5.50 kW

5.50 kW

SCOP

4.95

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.87 kW

4.87 kW

COP Tj = -7°C

2.96

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.96 kW

2.96 kW

COP Tj = +2°C

4.84

3.75

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.90 kW

1.90 kW

COP Tj = +7°C

6.46

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.02 kW

2.16 kW

COP Tj = 12°C

11.71

7.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.87 kW

4.87 kW

COP Tj = Tbiv

2.96

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.34 kW

5.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.16 kW

0.00 kW

Annual energy consumption Qhe

2295 kWh

2950 kWh

ACHP-H06/4R2HA-M(NE)
Configure model
Model name
ACHP-H06/4R2HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.35 kW

6.40 kW

El input

1.27 kW

1.97 kW

COP

5.00

3.25

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

151 %

Prated

6.80 kW

6.30 kW

SCOP

4.92

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.02 kW

5.57 kW

COP Tj = -7°C

2.85

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.66 kW

3.39 kW

COP Tj = +2°C

4.98

3.72

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.35 kW

2.18 kW

COP Tj = +7°C

6.38

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.17 kW

2.07 kW

COP Tj = 12°C

9.67

7.91

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.02 kW

5.57 kW

COP Tj = Tbiv

2.85

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.42 kW

6.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

2 W

2 W

PTO

30 W

30 W

PSB

2 W

2 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

0.30 kW

Annual energy consumption Qhe

2818 kWh

3381 kWh