SHEEN EVO 2.0 PRM 45.2, 50.2, 55.2

Certificate Holder
Clivet s.p.a.
Via camp lonc 25 c.ap.
I-32032 z.i. Villapaiera - Feltre (BL)
Italy
Registration number
ICIM-PDC-000235
Certification Body
ICIM S.p.A.
Subtype title
SHEEN EVO 2.0 PRM 45.2, 50.2, 55.2
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

17,500 kg

Certification Date
25.01.2024
Testing basis
V12
Generate PDF Export model CSV Download certificate
  • Number of models 6

Models

WiSAN-YSE1 PRM-SC 45.2
Configure model
Model name
WiSAN-YSE1 PRM-SC 45.2
Application
Heating (low temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

118.50 kW

El input

31.35 kW

COP

3.78

Average Climate

EN 12102-1

Sound power level outdoor

84 dB(A)

EN 14825

ηs

161 %

Prated

79.13 kW

SCOP

4.11

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

70.00 kW

COP Tj = -7°C

2.31

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

42.61 kW

COP Tj = +2°C

4.16

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

31.15 kW

COP Tj = +7°C

5.55

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

25.20 kW

COP Tj = 12°C

7.00

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

70.00 kW

COP Tj = Tbiv

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

67.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

35 °C

Poff

135 W

PTO

200 W

PSB

135 W

PCK

135 W

Supplementary Heater: Type of energy input

n/a

Supplementary Heater: PSUP

11.69 kW

Annual energy consumption Qhe

39779 kWh

WiSAN-YSE1 PRM-EN 45.2
Configure model
Model name
WiSAN-YSE1 PRM-EN 45.2
Application
Heating (low temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

99.50 kW

El input

26.05 kW

COP

3.82

Average Climate

EN 12102-1

Sound power level outdoor

79 dB(A)

EN 14825

ηs

160 %

Prated

71.22 kW

SCOP

4.07

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

63.00 kW

COP Tj = -7°C

2.26

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

38.35 kW

COP Tj = +2°C

4.16

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

31.15 kW

COP Tj = +7°C

5.55

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

25.20 kW

COP Tj = 12°C

7.00

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

63.00 kW

COP Tj = Tbiv

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

60.69 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

35 °C

Poff

135 W

PTO

200 W

PSB

135 W

PCK

135 W

Supplementary Heater: Type of energy input

n/a

Supplementary Heater: PSUP

10.52 kW

Annual energy consumption Qhe

36107 kWh

WiSAN-YSE1 PRM-SC 50.2
Configure model
Model name
WiSAN-YSE1 PRM-SC 50.2
Application
Heating (low temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

130.50 kW

El input

35.27 kW

COP

3.70

Average Climate

EN 12102-1

Sound power level outdoor

85 dB(A)

EN 14825

ηs

160 %

Prated

85.00 kW

SCOP

4.07

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

75.19 kW

COP Tj = -7°C

2.27

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

45.77 kW

COP Tj = +2°C

4.07

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

29.42 kW

COP Tj = +7°C

5.44

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

13.08 kW

COP Tj = 12°C

7.00

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

75.19 kW

COP Tj = Tbiv

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

72.44 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

35 °C

Poff

135 W

PTO

200 W

PSB

135 W

PCK

135 W

Supplementary Heater: Type of energy input

n/a

Supplementary Heater: PSUP

12.56 kW

Annual energy consumption Qhe

43122 kWh

WiSAN-YSE1 PRM-EN 50.2
Configure model
Model name
WiSAN-YSE1 PRM-EN 50.2
Application
Heating (low temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

105.70 kW

El input

28.04 kW

COP

3.77

Average Climate

EN 12102-1

Sound power level outdoor

80 dB(A)

EN 14825

ηs

158 %

Prated

74.61 kW

SCOP

4.02

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

66.00 kW

COP Tj = -7°C

2.25

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

40.17 kW

COP Tj = +2°C

4.07

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

31.15 kW

COP Tj = +7°C

5.44

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

25.20 kW

COP Tj = 12°C

7.00

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

66.00 kW

COP Tj = Tbiv

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

63.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

35 °C

Poff

135 W

PTO

200 W

PSB

135 W

PCK

135 W

Supplementary Heater: Type of energy input

n/a

Supplementary Heater: PSUP

11.03 kW

Annual energy consumption Qhe

38384 kWh

WiSAN-YSE1 PRM-SC 55.2
Configure model
Model name
WiSAN-YSE1 PRM-SC 55.2
Application
Heating (low temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

139.00 kW

El input

38.29 kW

COP

3.63

Average Climate

EN 12102-1

Sound power level outdoor

85 dB(A)

EN 14825

ηs

159 %

Prated

90.00 kW

SCOP

4.04

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

79.62 kW

COP Tj = -7°C

2.26

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

48.46 kW

COP Tj = +2°C

4.05

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

31.15 kW

COP Tj = +7°C

5.44

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

25.20 kW

COP Tj = 12°C

7.00

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

79.62 kW

COP Tj = Tbiv

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

76.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

35 °C

Poff

135 W

PTO

200 W

PSB

135 W

PCK

135 W

Supplementary Heater: Type of energy input

n/a

Supplementary Heater: PSUP

13.30 kW

Annual energy consumption Qhe

46047 kWh

WiSAN-YSE1 PRM-EN 55.2
Configure model
Model name
WiSAN-YSE1 PRM-EN 55.2
Application
Heating (low temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Heat output

114.00 kW

El input

30.48 kW

COP

3.74

Average Climate

EN 12102-1

Sound power level outdoor