Login

Subtype

TEAMAO 4 10/12/14 kW

Certificate Holder
FRISQUET SA
20 Rue Branly – Z.I.
77100 Meaux
France
Registration number
011-1W0561
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
TEAMAO 4 10/12/14 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,600 kg

Certification Date
01.12.2022
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 8

Models

TEAMAO 4 10 kW
Configure model
Model name
TEAMAO 4 10 kW
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.60 kW

3.08 kW

COP

5.00

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

131 %

Prated

10.00 kW

10.00 kW

SCOP

4.52

3.35

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

8.80 kW

8.80 kW

COP Tj = -7°C

3.10

2.00

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

5.70 kW

5.70 kW

COP Tj = +2°C

4.46

3.16

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.40 kW

5.20 kW

COP Tj = +7°C

5.68

4.77

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

4.50 kW

3.60 kW

COP Tj = 12°C

7.76

6.92

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

8.80 kW

8.80 kW

COP Tj = Tbiv

3.10

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.60 kW

8.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

1.93

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

17 W

16 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

1.40 kW

Annual energy consumption Qhe

4572 kWh

6174 kWh

TEAMAO 4 12 kW
Configure model
Model name
TEAMAO 4 12 kW
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.13 kW

3.77 kW

COP

4.70

2.65

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

11.70 kW

11.70 kW

SCOP

4.47

3.29

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

10.35 kW

10.35 kW

COP Tj = -7°C

2.78

1.94

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.30 kW

6.30 kW

COP Tj = +2°C

4.45

3.10

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.60 kW

5.30 kW

COP Tj = +7°C

5.83

4.73

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

4.40 kW

4.30 kW

COP Tj = 12°C

7.86

6.94

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.35 kW

10.35 kW

COP Tj = Tbiv

2.78

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.88

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

21 W

16 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.50 kW

Annual energy consumption Qhe

5409 kWh

7336 kWh

TEAMAO 4 14 kW
Configure model
Model name
TEAMAO 4 14 kW
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.90 kW

11.00 kW

El input

2.71 kW

4.23 kW

COP

4.39

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

126 %

Prated

13.60 kW

12.70 kW

SCOP

4.00

3.22

Tbiv

-4 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

10.43 kW

11.24 kW

COP Tj = -7°C

2.45

1.89

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.32 kW

6.84 kW

COP Tj = +2°C

3.91

3.00

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.60 kW

5.30 kW

COP Tj = +7°C

5.83

4.73

Cdh Tj = +7 °C

0.970

0.990

Pdh Tj = 12°C

4.40 kW

4.30 kW

COP Tj = 12°C

7.86

6.94

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.46 kW

11.24 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.75

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

26 W

17 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

2.10 kW

Annual energy consumption Qhe

7016 kWh

8144 kWh

TEAMAO 4 14 kW TRI
Configure model
Model name
TEAMAO 4 14 kW TRI
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.90 kW

11.00 kW

El input

2.71 kW

4.23 kW

COP

4.39

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

126 %

Prated

13.60 kW

12.70 kW

SCOP

4.00

3.22

Tbiv

-4 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

10.43 kW

11.24 kW

COP Tj = -7°C

2.45

1.89

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.32 kW

6.84 kW

COP Tj = +2°C

3.91

3.00

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.60 kW

5.30 kW

COP Tj = +7°C

5.83

4.73

Cdh Tj = +7 °C

0.970

0.990

Pdh Tj = 12°C

4.40 kW

4.30 kW

COP Tj = 12°C

7.86

6.94

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.46 kW

11.24 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.75

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

26 W

17 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

2.10 kW

Annual energy consumption Qhe

7016 kWh

8144 kWh

TEAMAO 4 SWELL 10kW
Configure model
Model name
TEAMAO 4 SWELL 10kW
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.60 kW

3.08 kW

COP

5.00

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

131 %

Prated

10.00 kW

10.00 kW

SCOP

4.52

3.35

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

8.80 kW

8.80 kW

COP Tj = -7°C

3.10

2.00

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

5.70 kW

5.70 kW

COP Tj = +2°C

4.46

3.16

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.40 kW

5.20 kW

COP Tj = +7°C

5.68

4.77

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

4.50 kW

3.60 kW

COP Tj = 12°C

7.76

6.92

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

8.80 kW

8.80 kW

COP Tj = Tbiv

3.10

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.60 kW

8.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.85

1.93

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

17 W

16 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.40 kW

1.40 kW

Annual energy consumption Qhe

4572 kWh

6174 kWh

TEAMAO 4 SWELL 12kW
Configure model
Model name
TEAMAO 4 SWELL 12kW
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.13 kW

3.77 kW

COP

4.70

2.65

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

129 %

Prated

11.70 kW

11.70 kW

SCOP

4.47

3.29

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

10.35 kW

10.35 kW

COP Tj = -7°C

2.78

1.94

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

6.30 kW

6.30 kW

COP Tj = +2°C

4.45

3.10

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.60 kW

5.30 kW

COP Tj = +7°C

5.83

4.73

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

4.40 kW

4.30 kW

COP Tj = 12°C

7.86

6.94

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.35 kW

10.35 kW

COP Tj = Tbiv

2.78

1.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.88

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

21 W

16 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.50 kW

1.50 kW

Annual energy consumption Qhe

5409 kWh

7336 kWh

TEAMAO 4 SWELL 14kW
Configure model
Model name
TEAMAO 4 SWELL 14kW
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.90 kW

11.00 kW

El input

2.71 kW

4.23 kW

COP

4.39

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

126 %

Prated

13.60 kW

12.70 kW

SCOP

4.00

3.22

Tbiv

-4 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

10.43 kW

11.24 kW

COP Tj = -7°C

2.45

1.89

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.32 kW

6.84 kW

COP Tj = +2°C

3.91

3.00

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.60 kW

5.30 kW

COP Tj = +7°C

5.83

4.73

Cdh Tj = +7 °C

0.970

0.990

Pdh Tj = 12°C

4.40 kW

4.30 kW

COP Tj = 12°C

7.86

6.94

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.46 kW

11.24 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.75

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

26 W

17 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

2.10 kW

Annual energy consumption Qhe

7016 kWh

8144 kWh

TEAMAO 4 SWELL 14kW TRI
Configure model
Model name
TEAMAO 4 SWELL 14kW TRI
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.90 kW

11.00 kW

El input

2.71 kW

4.23 kW

COP

4.39

2.60

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

126 %

Prated

13.60 kW

12.70 kW

SCOP

4.00

3.22

Tbiv

-4 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

10.43 kW

11.24 kW

COP Tj = -7°C

2.45

1.89

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

7.32 kW

6.84 kW

COP Tj = +2°C

3.91

3.00

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.60 kW

5.30 kW

COP Tj = +7°C

5.83

4.73

Cdh Tj = +7 °C

0.970

0.990

Pdh Tj = 12°C

4.40 kW

4.30 kW

COP Tj = 12°C

7.86

6.94

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

10.46 kW

11.24 kW

COP Tj = Tbiv

2.84

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.75

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

26 W

17 W

PSB

16 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

2.10 kW

Annual energy consumption Qhe

7016 kWh

8144 kWh