1,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.00 kW
6.00 kW
El input
1.26 kW
2.26 kW
COP
4.76
2.65
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
131 %
Prated
8.00 kW
8.00 kW
SCOP
4.53
3.34
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
7.10 kW
7.10 kW
COP Tj = -7°C
3.00
2.03
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
4.70 kW
4.30 kW
COP Tj = +2°C
4.45
3.16
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.10 kW
5.30 kW
COP Tj = +7°C
6.00
4.86
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.20 kW
3.10 kW
COP Tj = 12°C
8.00
6.47
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
7.10 kW
7.10 kW
COP Tj = Tbiv
3.00
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.93
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.30 kW
1.30 kW
Annual energy consumption Qhe
3652 kWh
4946 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.00 kW
6.00 kW
El input
1.26 kW
2.26 kW
COP
4.76
2.65
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
131 %
Prated
8.00 kW
8.00 kW
SCOP
4.53
3.34
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
7.10 kW
7.10 kW
COP Tj = -7°C
3.00
2.03
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
4.70 kW
4.30 kW
COP Tj = +2°C
4.45
3.16
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
5.10 kW
5.30 kW
COP Tj = +7°C
6.00
4.86
Cdh Tj = +7 °C
0.980
0.990
Pdh Tj = 12°C
3.20 kW
3.10 kW
COP Tj = 12°C
8.00
6.47
Cdh Tj = +12 °C
0.960
0.970
Pdh Tj = Tbiv
7.10 kW
7.10 kW
COP Tj = Tbiv
3.00
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.70 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.93
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.30 kW
1.30 kW
Annual energy consumption Qhe
3652 kWh
4946 kWh