0,970 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.30 kW
3.10 kW
El input
0.65 kW
1.22 kW
COP
5.07
2.55
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
125 %
Prated
4.40 kW
4.20 kW
SCOP
4.60
3.21
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.90 kW
3.70 kW
COP Tj = -7°C
3.09
1.96
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
2.40 kW
2.30 kW
COP Tj = +2°C
4.43
3.09
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.10 kW
1.80 kW
COP Tj = +7°C
6.07
4.37
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.40 kW
2.30 kW
COP Tj = 12°C
7.85
6.19
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
3.90 kW
3.70 kW
COP Tj = Tbiv
3.09
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.90 kW
3.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.76
1.63
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
1.000
WTOL
55 °C
55 °C
Poff
4 W
4 W
PTO
9 W
9 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.50 kW
0.90 kW
Annual energy consumption Qhe
1977 kWh
2707 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
132 %
COP
3.30
Heating up time
1:30 h:min
Standby power input
30.0 W
Reference hot water temperature
54.0 °C
Mixed water at 40°C
216 l