8,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
35.36 kW
33.33 kW
El input
8.74 kW
11.83 kW
COP
4.04
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
32 dB(A)
32 dB(A)
Sound power level outdoor
71 dB(A)
72 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
134 %
Prated
32.41 kW
37.01 kW
SCOP
3.98
3.44
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
28.67 kW
32.74 kW
COP Tj = -7°C
2.82
2.04
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
18.20 kW
19.98 kW
COP Tj = +2°C
4.04
3.50
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
15.76 kW
16.23 kW
COP Tj = +7°C
5.01
4.51
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
17.48 kW
18.95 kW
COP Tj = 12°C
5.69
5.93
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
28.67 kW
32.74 kW
COP Tj = Tbiv
2.82
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
26.09 kW
31.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
36 W
36 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.32 kW
5.71 kW
Annual energy consumption Qhe
16825 kWh
22261 kWh