Login

Subtype

DC Inverter Type Air to Water Unit- R410A- 30kW

Certificate Holder
Zhongshan Amitime Electric Co., Ltd
5th Yandong Rd
Zhongshan City - Guangdong
China
Registration number
041-K027-21
Certification Body
BRE Global Limited
Subtype title
DC Inverter Type Air to Water Unit- R410A- 30kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

5,200 kg

Certification Date
31.10.2023
Testing basis
Heat Pump KEYMARK certification Scheme rules v12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Indoor unit: PAEVH-30V4DEA/IA, Outdoor unit: PAEVH-30V4DEA
Configure model
Model name
Indoor unit: PAEVH-30V4DEA/IA, Outdoor unit: PAEVH-30V4DEA
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.71 kW

27.22 kW

El input

3.99 kW

10.61 kW

COP

4.43

2.57

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

Sound power level outdoor

66 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

125 %

Prated

26.53 kW

24.61 kW

SCOP

4.04

3.21

Tbiv

-7 °C

-7 °C

TOL

-28 °C

-28 °C

Pdh Tj = -7°C

23.47 kW

21.77 kW

COP Tj = -7°C

2.76

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

14.31 kW

14.08 kW

COP Tj = +2°C

4.10

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

12.85 kW

11.39 kW

COP Tj = +7°C

5.04

4.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

13.87 kW

13.20 kW

COP Tj = 12°C

6.40

5.47

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

23.47 kW

21.77 kW

COP Tj = Tbiv

2.76

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

21.64 kW

20.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

10 W

10 W

PTO

12 W

12 W

PSB

10 W

10 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.89 kW

4.02 kW

Annual energy consumption Qhe

13563 kWh

15836 kWh