1,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
3.90 kW
El input
1.12 kW
1.44 kW
COP
4.67
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
240 %
150 %
Prated
5 kW
5 kW
SCOP
6.07
3.84
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.94 kW
3.71 kW
COP Tj = +2°C
3.55
2.12
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.3 kW
3.28 kW
COP Tj = +7°C
5.52
3.39
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
2.76 kW
2.32 kW
COP Tj = 12°C
7.7
5.03
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
4.23 kW
4.02 kW
COP Tj = Tbiv
3.96
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.94 kW
3.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.55
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.06 kW
1.29 kW
Annual energy consumption Qhe
1101 kWh
1741 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
148 %
108 %
Prated
5 kW
5 kW
SCOP
3.77
2.76
Tbiv
-12 °C
-11 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
3.15 kW
3.18 kW
COP Tj = -7°C
3.4
2.44
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
1.9 kW
1.89 kW
COP Tj = +2°C
4.61
3.55
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.27 kW
1.62 kW
COP Tj = +7°C
6.12
4.27
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.09 kW
1.79 kW
COP Tj = 12°C
5.97
5.18
Cdh Tj = +12 °C
0.97
0.97
Pdh Tj = Tbiv
3.69 kW
3.39 kW
COP Tj = Tbiv
3
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.24 kW
2.45 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.59
1.4
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5 kW
5 kW
Annual energy consumption Qhe
3267 kWh
4461 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.26
2.77
COP Tj = -15°C (if TOL<-20°C)
2.43
1.59
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
125 %
Prated
5.00 kW
5.60 kW
SCOP
4.72
3.20
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.36 kW
3.80 kW
COP Tj = -7°C
2.96
1.92
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.73 kW
3.30 kW
COP Tj = +2°C
4.68
3.27
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.34 kW
2.01 kW
COP Tj = +7°C
6.07
4.24
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.77 kW
2.51 kW
COP Tj = 12°C
8.02
5.80
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.36 kW
4.15 kW
COP Tj = Tbiv
2.96
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.93 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.07 kW
3.00 kW
Annual energy consumption Qhe
2186 kWh
3613 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
152 %
COP
3.68
Heating up time
02:30 h:min
Standby power input
33 W
Reference hot water temperature
53.6 °C
Mixed water at 40°C
277 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
100 %
COP
2.42
Heating up time
02:44 h:min
Standby power input
41 W
Reference hot water temperature
53.5 °C
Mixed water at 40°C
270 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
125 %
COP
3.02
Heating up time
02:34 h:min
Standby power input
38 W
Reference hot water temperature
53.7 °C
Mixed water at 40°C
279 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
3.90 kW
El input
1.12 kW
1.44 kW
COP
4.67
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
240 %
150 %
Prated
5 kW
5 kW
SCOP
6.07
3.84
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.94 kW
3.71 kW
COP Tj = +2°C
3.55
2.12
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.3 kW
3.28 kW
COP Tj = +7°C
5.52
3.39
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
2.76 kW
2.32 kW
COP Tj = 12°C
7.7
5.03
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
4.23 kW
4.02 kW
COP Tj = Tbiv
3.96
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.94 kW
3.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.55
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.06 kW
1.29 kW
Annual energy consumption Qhe
1101 kWh
1741 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
148 %
108 %
Prated
5 kW
5 kW
SCOP
3.77
2.76
Tbiv
-12 °C
-11 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
3.15 kW
3.18 kW
COP Tj = -7°C
3.4
2.44
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
1.9 kW
1.89 kW
COP Tj = +2°C
4.61
3.55
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.27 kW
1.62 kW
COP Tj = +7°C
6.12
4.27
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.09 kW
1.79 kW
COP Tj = 12°C
5.97
5.18
Cdh Tj = +12 °C
0.97
0.97
Pdh Tj = Tbiv
3.69 kW
3.39 kW
COP Tj = Tbiv
3
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.24 kW
2.45 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.59
1.4
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
5 kW
5 kW
Annual energy consumption Qhe
3267 kWh
4461 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.26
2.77
COP Tj = -15°C (if TOL<-20°C)
2.43
1.59
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
125 %
Prated
5.00 kW
5.60 kW
SCOP
4.72
3.20
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.36 kW
3.80 kW
COP Tj = -7°C
2.96
1.92
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.73 kW
3.30 kW
COP Tj = +2°C
4.68
3.27
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.34 kW
2.01 kW
COP Tj = +7°C
6.07
4.24
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.77 kW
2.51 kW
COP Tj = 12°C
8.02
5.80
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.36 kW
4.15 kW
COP Tj = Tbiv
2.96
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.93 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.07 kW
3.00 kW
Annual energy consumption Qhe
2186 kWh
3613 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.21 kW
3.9 kW
El input
1.12 kW
1.44 kW
COP
4.67
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
240 %
150 %
Prated
5 kW
5 kW
SCOP
6.07
3.84
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.94 kW
3.71 kW
COP Tj = +2°C
3.55
2.12
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
3.3 kW
3.28 kW
COP Tj = +7°C
5.52
3.39
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
2.76 kW
2.32 kW
COP Tj = 12°C
7.7
5.03
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
4.23 kW
4.02 kW
COP Tj = Tbiv
3.96
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.94 kW
3.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.55
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.06 kW
1.29 kW
Annual energy consumption Qhe
1101 kWh
1741 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
148 %
108 %
Prated
5 kW
5 kW
SCOP
3.77
2.76
Tbiv
-12 °C
-11 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
3.15 kW
3.18 kW
COP Tj = -7°C
3.4
2.44
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
1.9 kW
1.89 kW
COP Tj = +2°C
4.61
3.55
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.27 kW
1.62 kW
COP Tj = +7°C
6.12
4.27
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.09 kW
1.79 kW
COP Tj = 12°C
5.97
5.18
Cdh Tj = +12 °C
0.97
0.97
Pdh Tj = Tbiv
3.69 kW
3.39 kW
COP Tj = Tbiv
3
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.24 kW
2.45 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.59
1.4
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5 kW
5 kW
Annual energy consumption Qhe
3267 kWh
4461 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.26
2.77
COP Tj = -15°C (if TOL<-20°C)
2.43
1.59
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
125 %
Prated
5 kW
5.6 kW
SCOP
4.72
3.20
Tbiv
-7 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.36 kW
3.80 kW
COP Tj = -7°C
2.96
1.92
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.73 kW
3.30 kW
COP Tj = +2°C
4.68
3.27
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.34 kW
2.01 kW
COP Tj = +7°C
6.07
4.24
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.77 kW
2.51 kW
COP Tj = 12°C
8.02
5.80
Cdh Tj = +12 °C
0.97
0.97
Pdh Tj = Tbiv
4.36 kW
4.15 kW
COP Tj = Tbiv
2.96
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.93 kW
2.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.07 kW
3.00 kW
Annual energy consumption Qhe
2186 kWh
3613 kWh