1,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.16 kW
5 kW
El input
1.3 kW
1.92 kW
COP
4.74
2.6
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
164 %
Prated
8 kW
8 kW
SCOP
6.31
4.17
Tbiv
4 °C
3 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.98 kW
6.93 kW
COP Tj = +2°C
3.72
2.34
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.93 kW
4.92 kW
COP Tj = +7°C
5.45
3.37
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.44 kW
3.15 kW
COP Tj = 12°C
8.29
5.59
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
6.43 kW
7.28 kW
COP Tj = Tbiv
4.15
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.98 kW
6.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.02 kW
1.07 kW
Annual energy consumption Qhe
1694 kWh
2563 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
106 %
Prated
6 kW
6 kW
SCOP
3.89
2.72
Tbiv
-12 °C
-13 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
3.72 kW
3.57 kW
COP Tj = -7°C
3.43
2.28
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.31 kW
2.06 kW
COP Tj = +2°C
4.83
3.44
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.89 kW
2.6 kW
COP Tj = +7°C
6.27
4.47
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
3.43 kW
3.22 kW
COP Tj = 12°C
8.11
6.04
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
4.34 kW
4.36 kW
COP Tj = Tbiv
2.74
1.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.11 kW
3.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.05
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6 kW
6 kW
Annual energy consumption Qhe
3800 kWh
5439 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.81
3.89
COP Tj = -15°C (if TOL<-20°C)
2.43
1.5
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
126 %
Prated
6.00 kW
7.00 kW
SCOP
4.63
3.22
Tbiv
-6 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.76 kW
5.10 kW
COP Tj = -7°C
2.88
1.86
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.16 kW
3.87 kW
COP Tj = +2°C
4.69
3.24
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.86 kW
2.60 kW
COP Tj = +7°C
6.04
4.41
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.46 kW
3.18 kW
COP Tj = 12°C
8.16
5.82
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
4.69 kW
5.78 kW
COP Tj = Tbiv
2.94
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.46 kW
2.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.54 kW
4.40 kW
Annual energy consumption Qhe
2678 kWh
4489 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
150 %
COP
3.62
Heating up time
02:53 h:min
Standby power input
35.1 W
Reference hot water temperature
53.8 °C
Mixed water at 40°C
275 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
105 %
COP
2.54
Heating up time
02:47 h:min
Standby power input
43.6 W
Reference hot water temperature
53.6 °C
Mixed water at 40°C
273 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
124 %
COP
2.99
Heating up time
02:33 h:min
Standby power input
41.5 W
Reference hot water temperature
53.8 °C
Mixed water at 40°C
274 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.16 kW
5 kW
El input
1.3 kW
1.92 kW
COP
4.74
2.6
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
164 %
Prated
8 kW
8 kW
SCOP
6.31
4.17
Tbiv
4 °C
3 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.98 kW
6.93 kW
COP Tj = +2°C
3.72
2.34
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.93 kW
4.92 kW
COP Tj = +7°C
5.45
3.37
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.44 kW
3.15 kW
COP Tj = 12°C
8.29
5.59
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
6.43 kW
7.28 kW
COP Tj = Tbiv
4.15
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.98 kW
6.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.02 kW
1.07 kW
Annual energy consumption Qhe
1694 kWh
2563 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
106 %
Prated
6 kW
6 kW
SCOP
3.89
2.72
Tbiv
-12 °C
-13 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
3.72 kW
3.57 kW
COP Tj = -7°C
3.43
2.28
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.31 kW
2.06 kW
COP Tj = +2°C
4.83
3.44
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.89 kW
2.6 kW
COP Tj = +7°C
6.27
4.47
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
3.43 kW
3.22 kW
COP Tj = 12°C
8.11
6.04
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
4.34 kW
4.36 kW
COP Tj = Tbiv
2.74
1.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.11 kW
3.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.05
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6 kW
6 kW
Annual energy consumption Qhe
3800 kWh
5439 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.81
3.89
COP Tj = -15°C (if TOL<-20°C)
2.43
1.5
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
126 %
Prated
6.00 kW
7.00 kW
SCOP
4.63
3.22
Tbiv
-6 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.76 kW
5.10 kW
COP Tj = -7°C
2.88
1.86
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.16 kW
3.87 kW
COP Tj = +2°C
4.69
3.24
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.86 kW
2.60 kW
COP Tj = +7°C
6.04
4.41
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.46 kW
3.18 kW
COP Tj = 12°C
8.16
5.82
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
4.69 kW
5.78 kW
COP Tj = Tbiv
2.94
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.46 kW
2.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.54 kW
4.40 kW
Annual energy consumption Qhe
2678 kWh
4489 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.16 kW
5 kW
El input
1.3 kW
1.92 kW
COP
4.74
2.6
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
164 %
Prated
8 kW
8 kW
SCOP
6.31
4.17
Tbiv
4 °C
3 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.98 kW
6.93 kW
COP Tj = +2°C
3.72
2.34
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.93 kW
4.92 kW
COP Tj = +7°C
5.45
3.37
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.44 kW
3.15 kW
COP Tj = 12°C
8.29
5.59
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
6.43 kW
7.28 kW
COP Tj = Tbiv
4.15
2.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.98 kW
6.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.72
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.02 kW
1.07 kW
Annual energy consumption Qhe
1694 kWh
2563 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
106 %
Prated
6 kW
6 kW
SCOP
3.89
2.72
Tbiv
-12 °C
-13 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
3.72 kW
3.57 kW
COP Tj = -7°C
3.43
2.28
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.31 kW
2.06 kW
COP Tj = +2°C
4.83
3.44
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.89 kW
2.6 kW
COP Tj = +7°C
6.27
4.47
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
3.43 kW
3.22 kW
COP Tj = 12°C
8.11
6.04
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
4.34 kW
4.36 kW
COP Tj = Tbiv
2.74
1.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.11 kW
3.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.05
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
6 kW
6 kW
Annual energy consumption Qhe
3800 kWh
5439 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.81
3.89
COP Tj = -15°C (if TOL<-20°C)
2.43
1.5
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
126 %
Prated
6.00 kW
7.00 kW
SCOP
4.63
3.22
Tbiv
-6 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.76 kW
5.10 kW
COP Tj = -7°C
2.88
1.86
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
3.16 kW
3.87 kW
COP Tj = +2°C
4.69
3.24
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.86 kW
2.60 kW
COP Tj = +7°C
6.04
4.41
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
3.46 kW
3.18 kW
COP Tj = 12°C
8.16
5.82
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
4.69 kW
5.78 kW
COP Tj = Tbiv
2.94
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.46 kW
2.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.67
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.54 kW
4.40 kW
Annual energy consumption Qhe
2678 kWh
4489 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.02 kW
6.78 kW
El input
1.71 kW
2.52 kW
COP
4.7
2.69
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
166 %
Prated
9 kW
9 kW
SCOP
6.39
4.23
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.35 kW
6.93 kW
COP Tj = +2°C
3.47
2.34
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.63 kW
5.98 kW
COP Tj = +7°C
5.43
3.4
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.46 kW
3.17 kW
COP Tj = 12°C
8.46
5.77
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
7.88 kW
7.65 kW
COP Tj = Tbiv
3.88
2.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.35 kW
6.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.65 kW
2.07 kW
Annual energy consumption Qhe
1883 kWh
2846 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
107 %
Prated
7 kW
7 kW
SCOP
3.9
2.75
Tbiv
-14 °C
-11 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
4.42 kW
4.29 kW
COP Tj = -7°C
3.24
2.27
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.58 kW
2.71 kW
COP Tj = +2°C
4.92
3.62
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.86 kW
2.63 kW
COP Tj = +7°C
6.31
4.58
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.44 kW
3.23 kW
COP Tj = 12°C
8.2
6.1
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
5.4 kW
4.84 kW
COP Tj = Tbiv
2.4
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.89 kW
3.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.84
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7 kW
7 kW
Annual energy consumption Qhe
4422 kWh
6273 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.23
3.89
COP Tj = -15°C (if TOL<-20°C)
2.34
1.5
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
126 %
Prated
8 kW
7 kW
SCOP
4.71
3.22
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.08 kW
5.10 kW
COP Tj = -7°C
2.82
1.86
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
4.39 kW
3.87 kW
COP Tj = +2°C
4.82
3.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.85 kW
2.60 kW
COP Tj = +7°C
6.33
4.41
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.46 kW
3.18 kW
COP Tj = 12°C
8.51
5.82
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
6.54 kW
5.78 kW
COP Tj = Tbiv
3.05
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.55 kW
2.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.45 kW
4.40 kW
Annual energy consumption Qhe
3512 kWh
4489 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
150 %
COP
3.62
Heating up time
02:53 h:min
Standby power input
35.1 W
Reference hot water temperature
53.8 °C
Mixed water at 40°C
275 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
105 %
COP
2.54
Heating up time
02:47 h:min
Standby power input
43.6 W
Reference hot water temperature
53.6 °C
Mixed water at 40°C
273 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
124 %
COP
2.99
Heating up time
02:33 h:min
Standby power input
41.5 W
Reference hot water temperature
53.8 °C
Mixed water at 40°C
274 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.02 kW
6.78 kW
El input
1.71 kW
2.52 kW
COP
4.7
2.69
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
166 %
Prated
9 kW
9 kW
SCOP
6.39
4.23
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.35 kW
6.93 kW
COP Tj = +2°C
3.47
2.34
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.63 kW
5.98 kW
COP Tj = +7°C
5.43
3.4
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.46 kW
3.17 kW
COP Tj = 12°C
8.46
5.77
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
7.88 kW
7.65 kW
COP Tj = Tbiv
3.88
2.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.35 kW
6.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.65 kW
2.07 kW
Annual energy consumption Qhe
1883 kWh
2846 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
107 %
Prated
7 kW
7 kW
SCOP
3.9
2.75
Tbiv
-14 °C
-11 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
4.42 kW
4.29 kW
COP Tj = -7°C
3.24
2.27
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.58 kW
2.71 kW
COP Tj = +2°C
4.92
3.62
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.86 kW
2.63 kW
COP Tj = +7°C
6.31
4.58
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.44 kW
3.23 kW
COP Tj = 12°C
8.2
6.1
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
5.4 kW
4.84 kW
COP Tj = Tbiv
2.4
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.89 kW
3.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.84
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7 kW
7 kW
Annual energy consumption Qhe
4422 kWh
6273 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.23
3.89
COP Tj = -15°C (if TOL<-20°C)
2.34
1.5
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
126 %
Prated
8 kW
7 kW
SCOP
4.71
3.22
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.08 kW
5.10 kW
COP Tj = -7°C
2.82
1.86
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
4.39 kW
3.87 kW
COP Tj = +2°C
4.82
3.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.85 kW
2.60 kW
COP Tj = +7°C
6.33
4.41
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.46 kW
3.18 kW
COP Tj = 12°C
8.51
5.82
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
6.54 kW
5.78 kW
COP Tj = Tbiv
3.05
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.55 kW
2.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.45 kW
4.40 kW
Annual energy consumption Qhe
3512 kWh
4489 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.02 kW
6.78 kW
El input
1.71 kW
2.52 kW
COP
4.7
2.69
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
166 %
Prated
9 kW
9 kW
SCOP
6.39
4.23
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.35 kW
6.93 kW
COP Tj = +2°C
3.47
2.34
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.63 kW
5.98 kW
COP Tj = +7°C
5.43
3.4
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.46 kW
3.17 kW
COP Tj = 12°C
8.46
5.77
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
7.88 kW
7.65 kW
COP Tj = Tbiv
3.88
2.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.35 kW
6.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.47
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.65 kW
2.07 kW
Annual energy consumption Qhe
1883 kWh
2846 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
107 %
Prated
7 kW
7 kW
SCOP
3.9
2.75
Tbiv
-14 °C
-11 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
4.42 kW
4.29 kW
COP Tj = -7°C
3.24
2.27
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.58 kW
2.71 kW
COP Tj = +2°C
4.92
3.62
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.86 kW
2.63 kW
COP Tj = +7°C
6.31
4.58
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.44 kW
3.23 kW
COP Tj = 12°C
8.2
6.1
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
5.4 kW
4.84 kW
COP Tj = Tbiv
2.4
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.89 kW
3.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.84
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
7 kW
7 kW
Annual energy consumption Qhe
4422 kWh
6273 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.23
3.89
COP Tj = -15°C (if TOL<-20°C)
2.34
1.5
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
126 %
Prated
8 kW
7 kW
SCOP
4.71
3.22
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.08 kW
5.10 kW
COP Tj = -7°C
2.82
1.86
Cdh Tj = -7 °C
0.99
1
Pdh Tj = +2°C
4.39 kW
3.87 kW
COP Tj = +2°C
4.82
3.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.85 kW
2.60 kW
COP Tj = +7°C
6.33
4.41
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.46 kW
3.18 kW
COP Tj = 12°C
8.51
5.82
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
6.54 kW
5.78 kW
COP Tj = Tbiv
3.05
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.55 kW
2.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.51
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.45 kW
4.40 kW
Annual energy consumption Qhe
3512 kWh
4489 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.92 kW
7.87 kW
El input
1.91 kW
2.89 kW
COP
4.68
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
255 %
169 %
Prated
10 kW
9.6 kW
SCOP
6.46
4.3
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.85 kW
6.93 kW
COP Tj = +2°C
3.38
2.34
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.92 kW
6.31 kW
COP Tj = +7°C
5.57
3.51
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.53 kW
3.19 kW
COP Tj = 12°C
8.72
5.87
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
8.41 kW
7.65 kW
COP Tj = Tbiv
3.77
2.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.85 kW
6.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.38
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.15 kW
2.67 kW
Annual energy consumption Qhe
2069 kWh
2980 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
107 %
Prated
8 kW
7.8 kW
SCOP
3.93
2.74
Tbiv
-14 °C
-10 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
4.74 kW
4.82 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.98 kW
2.84 kW
COP Tj = +2°C
5.01
3.64
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.71 kW
2.65 kW
COP Tj = +7°C
6.11
4.7
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.44 kW
3.23 kW
COP Tj = 12°C
8.24
6.15
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
6.15 kW
5.08 kW
COP Tj = Tbiv
2.49
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.4 kW
3.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.94
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8 kW
7.8 kW
Annual energy consumption Qhe
5012 kWh
7014 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.95
3.89
COP Tj = -15°C (if TOL<-20°C)
2.43
1.5
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
125 %
Prated
9 kW
8 kW
SCOP
4.53
3.21
Tbiv
-6 °C
-4 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.79 kW
5.10 kW
COP Tj = -7°C
2.81
1.86
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.78 kW
4.58 kW
COP Tj = +2°C
4.35
3.35
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.89 kW
2.57 kW
COP Tj = +7°C
6.47
4.29
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.53 kW
3.20 kW
COP Tj = 12°C
8.72
5.96
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
7.03 kW
6.10 kW
COP Tj = Tbiv
2.91
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.20 kW
2.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.80 kW
5.40 kW
Annual energy consumption Qhe
4103 kWh
5147 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
150 %
COP
3.62
Heating up time
02:53 h:min
Standby power input
35.1 W
Reference hot water temperature
53.8 °C
Mixed water at 40°C
275 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
105 %
COP
2.54
Heating up time
02:47 h:min
Standby power input
43.6 W
Reference hot water temperature
53.6 °C
Mixed water at 40°C
273 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
124 %
COP
2.99
Heating up time
02:33 h:min
Standby power input
41.5 W
Reference hot water temperature
53.8 °C
Mixed water at 40°C
274 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.92 kW
7.87 kW
El input
1.91 kW
2.89 kW
COP
4.68
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
255 %
169 %
Prated
10 kW
9.6 kW
SCOP
6.46
4.3
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.85 kW
6.93 kW
COP Tj = +2°C
3.38
2.34
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.92 kW
6.31 kW
COP Tj = +7°C
5.57
3.51
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.53 kW
3.19 kW
COP Tj = 12°C
8.72
5.87
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
8.41 kW
7.65 kW
COP Tj = Tbiv
3.77
2.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.85 kW
6.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.38
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.15 kW
2.67 kW
Annual energy consumption Qhe
2069 kWh
2980 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
107 %
Prated
8 kW
7.8 kW
SCOP
3.93
2.74
Tbiv
-14 °C
-10 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
4.74 kW
4.82 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.98 kW
2.84 kW
COP Tj = +2°C
5.01
3.64
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.71 kW
2.65 kW
COP Tj = +7°C
6.11
4.7
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.44 kW
3.23 kW
COP Tj = 12°C
8.24
6.15
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
6.15 kW
5.08 kW
COP Tj = Tbiv
2.49
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.4 kW
3.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.94
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8 kW
7.8 kW
Annual energy consumption Qhe
5012 kWh
7014 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.95
3.89
COP Tj = -15°C (if TOL<-20°C)
2.43
1.5
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
125 %
Prated
9 kW
8 kW
SCOP
4.53
3.21
Tbiv
-6 °C
-4 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.79 kW
5.10 kW
COP Tj = -7°C
2.81
1.86
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.78 kW
4.58 kW
COP Tj = +2°C
4.35
3.35
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.89 kW
2.57 kW
COP Tj = +7°C
6.47
4.29
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.53 kW
3.20 kW
COP Tj = 12°C
8.72
5.96
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
7.03 kW
6.10 kW
COP Tj = Tbiv
2.91
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.20 kW
2.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.80 kW
5.40 kW
Annual energy consumption Qhe
4103 kWh
5147 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.92 kW
7.87 kW
El input
1.91 kW
2.89 kW
COP
4.68
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
255 %
169 %
Prated
10 kW
9.6 kW
SCOP
6.46
4.3
Tbiv
4 °C
4 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.85 kW
6.93 kW
COP Tj = +2°C
3.38
2.34
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
5.92 kW
6.31 kW
COP Tj = +7°C
5.57
3.51
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
3.53 kW
3.19 kW
COP Tj = 12°C
8.72
5.87
Cdh Tj = +12 °C
0.98
0.98
Pdh Tj = Tbiv
8.41 kW
7.65 kW
COP Tj = Tbiv
3.77
2.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.85 kW
6.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.38
2.34
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.15 kW
2.67 kW
Annual energy consumption Qhe
2069 kWh
2980 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
107 %
Prated
8 kW
7.8 kW
SCOP
3.93
2.74
Tbiv
-14 °C
-10 °C
TOL
-20 °C
-17 °C
Pdh Tj = -7°C
4.74 kW
4.82 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.98 kW
2.84 kW
COP Tj = +2°C
5.01
3.64
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.71 kW
2.65 kW
COP Tj = +7°C
6.11
4.7
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.44 kW
3.23 kW
COP Tj = 12°C
8.24
6.15
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
6.15 kW
5.08 kW
COP Tj = Tbiv
2.49
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.4 kW
3.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.94
1.33
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
8 kW
7.8 kW
Annual energy consumption Qhe
5012 kWh
7014 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.95
3.89
COP Tj = -15°C (if TOL<-20°C)
2.43
1.5
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
125 %
Prated
9 kW
8 kW
SCOP
4.53
3.21
Tbiv
-6 °C
-4 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.79 kW
5.10 kW
COP Tj = -7°C
2.81
1.86
Cdh Tj = -7 °C
1
1
Pdh Tj = +2°C
4.78 kW
4.58 kW
COP Tj = +2°C
4.35
3.35
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.89 kW
2.57 kW
COP Tj = +7°C
6.47
4.29
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.53 kW
3.20 kW
COP Tj = 12°C
8.72
5.96
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
7.03 kW
6.10 kW
COP Tj = Tbiv
2.91
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.20 kW
2.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1
0.99
WTOL
60 °C
60 °C
Poff
11 W
11 W
PTO
0 W
0 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.80 kW
5.40 kW
Annual energy consumption Qhe
4103 kWh
5147 kWh