Login

Subtype

X-Force 16 kW T

Certificate Holder
Inventor A.G. Electric Appliances S.A.
2 Thoukididou str. & 24th km National Road Athens - Lamia
14565 Agios Stefanos
Greece
Registration number
041-K014-13
Certification Body
BRE Global Limited
Subtype title
X-Force 16 kW T
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,100 kg

Certification Date
06.02.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

XFM*16T*
Configure model
Model name
XFM*16T*
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.92 kW

16.38 kW

El input

3.64 kW

5.89 kW

COP

4.38

2.78

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

129 %

Prated

14.89 kW

12.93 kW

SCOP

4.50

3.30

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.18 kW

11.44 kW

COP Tj = -7°C

2.56

1.93

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.02 kW

7.41 kW

COP Tj = +2°C

4.42

3.35

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.90 kW

4.83 kW

COP Tj = +7°C

6.05

4.03

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.33 kW

5.68 kW

COP Tj = 12°C

8.44

5.83

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

13.18 kW

11.44 kW

COP Tj = Tbiv

2.56

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.47 kW

11.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.38

1.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

30 W

30 W

PSB

12 W

12 W

PCK

25 W

25 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.42 kW

1.25 kW

Annual energy consumption Qhe

6831 kWh

8097 kWh