Login

Subtype

M thermal A HT Series 8 10 kW

Certificate Holder
GD Midea Heating & Ventilating Equipment Co., Ltd.
Penglai Industry Road
528311 Beijiao, Shunde, Foshan
China
Registration number
ICIM-PDC-000198
Certification Body
ICIM S.p.A.
Subtype title
M thermal A HT Series 8 10 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,100 kg

Certification Date
08.09.2023
Testing basis
V12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

MHC-V8WD2N7-***
Configure model
Model name
MHC-V8WD2N7-***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.4 kW

7.8 kW

El input

1.68 kW

2.44 kW

COP

5.00

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

149 %

Prated

8.00 kW

6.80 kW

SCOP

5.19

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.09 kW

5.97 kW

COP Tj = -7°C

3.06

2.37

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.53 kW

3.71 kW

COP Tj = +2°C

5.10

3.85

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.96 kW

3.62 kW

COP Tj = +7°C

7.47

5.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.51 kW

4.31 kW

COP Tj = 12°C

9.66

6.77

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.09 kW

5.97 kW

COP Tj = Tbiv

3.06

2.37

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.97 kW

6.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.03 kW

0.34 kW

Annual energy consumption Qhe

3184 kWh

3676 kWh

MHC-V10WD2N7-***
Configure model
Model name
MHC-V10WD2N7-***
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.0 kW

9.5 kW

El input

2.13 kW

3.11 kW

COP

4.70

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

149 %

Prated

9.2 kW

7.8 kW

SCOP

5.07

3.82

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

8.11 kW

6.88 kW

COP Tj = -7°C

2.84

2.31

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.10 kW

4.23 kW

COP Tj = +2°C

4.96

3.80

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.96 kW

3.62 kW

COP Tj = +7°C

7.47

5.21

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.48 kW

4.31 kW

COP Tj = 12°C

9.56

6.86

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

8.11 kW

6.88 kW

COP Tj = Tbiv

2.84

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

7.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.99

WTOL

75.00 °C

75.00 °C

Poff

9.00 W

9.00 W

PTO

14.00 W

14.00 W

PSB

9.00 W

9.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.66 kW

0.35 kW

Annual energy consumption Qhe

3744 kWh

4215 kWh