Login

Subtype

X-Force 16 kW

Certificate Holder
Inventor A.G. Electric Appliances S.A.
2 Thoukididou str. & 24th km National Road Athens - Lamia
14565 Agios Stefanos
Greece
Registration number
041-K014-07 / 1
Certification Body
BRE Global Limited
Subtype title
X-Force 16 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,700 kg

Certification Date
19.12.2022
Testing basis
Heat Pump Keymark Scheme Rules Rev 09
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

XFM*16S*
Configure model
Model name
XFM*16S*
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.32 kW

16.31 kW

El input

3.56 kW

5.64 kW

COP

4.58

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

131 %

Prated

15.45 kW

13.03 kW

SCOP

4.55

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.67 kW

11.53 kW

COP Tj = -7°C

2.68

2.02

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

8.23 kW

7.34 kW

COP Tj = +2°C

4.35

3.12

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.51 kW

4.99 kW

COP Tj = +7°C

6.48

4.66

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.53 kW

6.22 kW

COP Tj = 12°C

9.43

7.41

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

13.67 kW

11.53 kW

COP Tj = Tbiv

2.68

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.13 kW

10.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.87

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

98 W

98 W

PTO

98 W

98 W

PSB

98 W

98 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.32 kW

2.24 kW

Annual energy consumption Qhe

7024 kWh

8023 kWh