Login

Subtype

Monobloc ACHP-H series 08/H10

Certificate Holder
Ningbo AUX Electric Co., Ltd
1166 Mingguang North Road
315191 Ningbo Zhejiang
China
Registration number
011-1W0586
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Monobloc ACHP-H series 08/H10
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,450 kg

Certification Date
17.02.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 12 (as of 2023-03)
Generate PDF Export model CSV
  • Number of models 6

Models

ACHP-H08/4R3HA-M
Configure model
Model name
ACHP-H08/4R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

8.30 kW

El input

1.62 kW

2.60 kW

COP

5.20

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

272 %

173 %

Prated

8.10 kW

7.60 kW

SCOP

6.51

4.24

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.80 kW

7.30 kW

COP Tj = +2°C

3.98

2.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.22 kW

4.89 kW

COP Tj = +7°C

5.88

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.31 kW

2.17 kW

COP Tj = 12°C

9.23

5.55

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.21 kW

4.89 kW

COP Tj = Tbiv

6.26

3.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

7.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.98

2.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

1573 kWh

2304 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

132 %

Prated

8.10 kW

6.60 kW

SCOP

5.20

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.18 kW

5.84 kW

COP Tj = -7°C

3.30

2.30

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.36 kW

3.55 kW

COP Tj = +2°C

5.09

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.80 kW

2.28 kW

COP Tj = +7°C

6.82

4.28

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.25 kW

1.02 kW

COP Tj = 12°C

8.35

5.33

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.17 kW

5.84 kW

COP Tj = Tbiv

3.30

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.44 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.66 kW

1.70 kW

Annual energy consumption Qhe

3216 kWh

4015 kWh

ACHP-H10/4R3HA-M
Configure model
Model name
ACHP-H10/4R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.00 kW

3.23 kW

COP

5.00

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

267 %

177 %

Prated

8.60 kW

8.60 kW

SCOP

6.42

4.36

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.20 kW

8.20 kW

COP Tj = +2°C

3.84

2.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.53 kW

5.53 kW

COP Tj = +7°C

5.85

3.93

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.46 kW

2.53 kW

COP Tj = 12°C

9.04

5.82

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.53 kW

5.53 kW

COP Tj = Tbiv

5.85

3.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.20 kW

8.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.84

2.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.40 kW

Annual energy consumption Qhe

1701 kWh

2545 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

9.20 kW

7.70 kW

SCOP

5.07

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.14 kW

6.81 kW

COP Tj = -7°C

3.17

2.03

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.95 kW

4.15 kW

COP Tj = +2°C

5.02

3.46

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.18 kW

2.67 kW

COP Tj = +7°C

6.30

4.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.42 kW

1.18 kW

COP Tj = 12°C

8.33

7.01

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.14 kW

6.81 kW

COP Tj = Tbiv

3.17

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.40 kW

5.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.47 kW

Annual energy consumption Qhe

3743 kWh

4553 kWh

ACHP-H08/4R3HA-M(NE)
Configure model
Model name
ACHP-H08/4R3HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

8.30 kW

El input

1.62 kW

2.60 kW

COP

5.20

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

272 %

173 %

Prated

8.10 kW

7.60 kW

SCOP

6.51

4.24

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.80 kW

7.30 kW

COP Tj = +2°C

3.98

2.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.22 kW

4.89 kW

COP Tj = +7°C

5.88

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.31 kW

2.17 kW

COP Tj = 12°C

9.23

5.55

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.21 kW

4.89 kW

COP Tj = Tbiv

6.26

3.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

7.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.98

2.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

1573 kWh

2304 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

132 %

Prated

8.10 kW

6.60 kW

SCOP

5.20

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.18 kW

5.84 kW

COP Tj = -7°C

3.30

2.30

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.36 kW

3.55 kW

COP Tj = +2°C

5.09

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.80 kW

2.28 kW

COP Tj = +7°C

6.82

4.28

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.25 kW

1.02 kW

COP Tj = 12°C

8.35

5.33

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.17 kW

5.84 kW

COP Tj = Tbiv

3.30

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.44 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.66 kW

1.70 kW

Annual energy consumption Qhe

3216 kWh

4015 kWh

ACHP-H10/4R3HA-M(NE)
Configure model
Model name
ACHP-H10/4R3HA-M(NE)
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.00 kW

3.23 kW

COP

5.00

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

267 %

177 %

Prated

8.60 kW

8.60 kW

SCOP

6.42

4.36

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.20 kW

8.20 kW

COP Tj = +2°C

3.84

2.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.53 kW

5.53 kW

COP Tj = +7°C

5.85

3.93

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.46 kW

2.53 kW

COP Tj = 12°C

9.04

5.82

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.53 kW

5.53 kW

COP Tj = Tbiv

5.85

3.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.20 kW

8.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.84

2.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.40 kW

Annual energy consumption Qhe

1701 kWh

2545 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

9.20 kW

7.70 kW

SCOP

5.07

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.14 kW

6.81 kW

COP Tj = -7°C

3.17

2.03

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.95 kW

4.15 kW

COP Tj = +2°C

5.02

3.46

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.18 kW

2.67 kW

COP Tj = +7°C

6.30

4.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.42 kW

1.18 kW

COP Tj = 12°C

8.33

7.01

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.14 kW

6.81 kW

COP Tj = Tbiv

3.17

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.40 kW

5.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.47 kW

Annual energy consumption Qhe

3743 kWh

4553 kWh

ACHP-H08/5R3HA-M
Configure model
Model name
ACHP-H08/5R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.40 kW

8.30 kW

El input

1.62 kW

2.60 kW

COP

5.20

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

272 %

173 %

Prated

8.10 kW

7.60 kW

SCOP

6.51

4.24

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.80 kW

7.30 kW

COP Tj = +2°C

3.98

2.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.22 kW

4.89 kW

COP Tj = +7°C

5.88

3.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.31 kW

2.17 kW

COP Tj = 12°C

9.23

5.55

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.21 kW

4.89 kW

COP Tj = Tbiv

6.26

3.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.80 kW

7.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.98

2.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.30 kW

0.30 kW

Annual energy consumption Qhe

1573 kWh

2304 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

132 %

Prated

8.10 kW

6.60 kW

SCOP

5.20

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.18 kW

5.84 kW

COP Tj = -7°C

3.30

2.30

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.36 kW

3.55 kW

COP Tj = +2°C

5.09

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.80 kW

2.28 kW

COP Tj = +7°C

6.82

4.28

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.25 kW

1.02 kW

COP Tj = 12°C

8.35

5.33

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.17 kW

5.84 kW

COP Tj = Tbiv

3.30

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.44 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.04

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.66 kW

1.70 kW

Annual energy consumption Qhe

3216 kWh

4015 kWh

ACHP-H10/5R3HA-M
Configure model
Model name
ACHP-H10/5R3HA-M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.00 kW

10.00 kW

El input

2.00 kW

3.23 kW

COP

5.00

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

267 %

177 %

Prated

8.60 kW

8.60 kW

SCOP

6.42

4.36

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.20 kW

8.20 kW

COP Tj = +2°C

3.84

2.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.53 kW

5.53 kW

COP Tj = +7°C

5.85

3.93

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.46 kW

2.53 kW

COP Tj = 12°C

9.04

5.82

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.53 kW

5.53 kW

COP Tj = Tbiv

5.85

3.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.20 kW

8.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.84

2.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.40 kW

Annual energy consumption Qhe

1701 kWh

2545 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

136 %

Prated

9.20 kW

7.70 kW

SCOP

5.07

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.14 kW

6.81 kW

COP Tj = -7°C

3.17

2.03

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.95 kW

4.15 kW

COP Tj = +2°C

5.02

3.46

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.18 kW

2.67 kW

COP Tj = +7°C

6.30

4.50

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.42 kW

1.18 kW

COP Tj = 12°C

8.33

7.01

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.14 kW

6.81 kW

COP Tj = Tbiv

3.17

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.40 kW

5.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.63

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

20 W

20 W

PTO

30 W

30 W

PSB

20 W

20 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.47 kW

Annual energy consumption Qhe

3743 kWh

4553 kWh