5,910 kg
Heating
EN 14511-2
Heat output
31.63 kW
El input
9.87 kW
COP
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Sound power level indoor
44 dB(A)
Sound power level outdoor
88 dB(A)
EN 14825
ηs
153 %
Prated
17.00 kW
SCOP
3.89
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
15.70 kW
COP Tj = -7°C
2.70
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
9.40 kW
COP Tj = +2°C
3.74
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
6.10 kW
COP Tj = +7°C
4.91
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
6.40 kW
COP Tj = 12°C
6.17
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
16.90 kW
COP Tj = Tbiv
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
50 °C
Poff
55 W
PTO
26 W
PSB
55 W
PCK
1 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
8956 kWh