10,910 kg
Heating
EN 14511-2
Heat output
30.29 kW
El input
8.36 kW
COP
3.62
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Sound power level indoor
44 dB(A)
Sound power level outdoor
88 dB(A)
EN 14825
ηs
142 %
Prated
17.00 kW
SCOP
3.63
Tbiv
-10 °C
TOL
-10 °C
Pdh Tj = -7°C
15.30 kW
COP Tj = -7°C
2.53
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
9.50 kW
COP Tj = +2°C
3.72
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
6.40 kW
COP Tj = +7°C
4.98
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
5.40 kW
COP Tj = 12°C
5.71
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
16.90 kW
COP Tj = Tbiv
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.35
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
50 °C
Poff
132 W
PTO
131 W
PSB
132 W
PCK
4 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
0.00 kW
Annual energy consumption Qhe
9603 kWh