Login

Subtype

LIA 0608HXCF M

Certificate Holder
Glen Dimplex Deutschland GmbH
Am Goldenen Feld 18
D-95326 Kulmbach
Germany
Registration number
041-K029-03
Certification Body
BRE Global Limited
Subtype title
LIA 0608HXCF M
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,500 kg

Certification Date
08.06.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 11
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

LIA 0608 M + LIA HX
Configure model
Model name
LIA 0608 M + LIA HX
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.20 kW

6.00 kW

El input

1.24 kW

2.00 kW

COP

5.00

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

258 %

165 %

Prated

6.12 kW

5.15 kW

SCOP

6.63

4.19

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.94 kW

5.03 kW

COP Tj = +2°C

3.91

2.48

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.93 kW

3.31 kW

COP Tj = +7°C

5.89

3.67

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.80 kW

1.60 kW

COP Tj = 12°C

8.20

5.29

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

3.93 kW

3.31 kW

COP Tj = Tbiv

5.89

3.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.94 kW

5.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.91

2.48

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.18 kW

0.12 kW

Annual energy consumption Qhe

1251 kWh

1640 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

111 %

Prated

5.63 kW

4.26 kW

SCOP

4.21

2.85

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.42 kW

2.70 kW

COP Tj = -7°C

3.59

2.46

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

2.06 kW

1.61 kW

COP Tj = +2°C

5.21

3.36

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

1.47 kW

1.02 kW

COP Tj = +7°C

6.24

3.94

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.44 kW

1.37 kW

COP Tj = 12°C

7.66

6.35

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

4.60 kW

3.48 kW

COP Tj = Tbiv

2.53

1.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.48 kW

2.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.96

1.13

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.15 kW

2.16 kW

Annual energy consumption Qhe

3301 kWh

3681 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.60

3.48

COP Tj = -15°C (if TOL<-20°C)

2.53

1.86

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

138 %

Prated

6.82 kW

5.70 kW

SCOP

4.95

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.03 kW

5.05 kW

COP Tj = -7°C

3.09

2.17

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.88 kW

3.12 kW

COP Tj = +2°C

4.85

3.51

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

2.40 kW

2.09 kW

COP Tj = +7°C

6.63

4.54

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

1.39 kW

1.28 kW

COP Tj = 12°C

7.83

5.59

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.03 kW

5.05 kW

COP Tj = Tbiv

3.09

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.36 kW

4.52 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.76

1.91

WTOL

65 °C

65 °C

Poff

14 W

14 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.45 kW

1.18 kW

Annual energy consumption Qhe

2846 kWh

3345 kWh