Login

Subtype

Intelligent Inverter Heat Pump R32- P24T, P24T-B

Certificate Holder
Guangdong PHNIX Eco-Energy Solutions Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-10
Certification Body
BRE Global Limited
Subtype title
Intelligent Inverter Heat Pump R32- P24T, P24T-B
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

3,400 kg

Certification Date
05.09.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

P24T
Configure model
Model name
P24T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

24.15 kW

23.42 kW

El input

5.56 kW

8.24 kW

COP

4.34

2.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

121 %

Prated

18.04 kW

18.19 kW

SCOP

4.10

3.11

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

15.96 kW

16.09 kW

COP Tj = -7°C

2.93

2.07

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

9.86 kW

9.81 kW

COP Tj = +2°C

3.94

3.02

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

9.66 kW

9.61 kW

COP Tj = +7°C

4.93

3.76

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

11.44 kW

11.41 kW

COP Tj = 12°C

6.57

5.13

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.96 kW

16.09 kW

COP Tj = Tbiv

2.93

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.13 kW

18.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

59 W

59 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.01 kW

Annual energy consumption Qhe

9081 kWh

12100 kWh

P24T-B
Configure model
Model name
P24T-B
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

24.15 kW

23.42 kW

El input

5.56 kW

8.24 kW

COP

4.34

2.84

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

70 dB(A)

71 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

121 %

Prated

18.04 kW

18.19 kW

SCOP

4.10

3.11

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

15.96 kW

16.09 kW

COP Tj = -7°C

2.93

2.07

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

9.86 kW

9.81 kW

COP Tj = +2°C

3.94

3.02

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

9.66 kW

9.61 kW

COP Tj = +7°C

4.93

3.76

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

11.44 kW

11.41 kW

COP Tj = 12°C

6.57

5.13

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

15.96 kW

16.09 kW

COP Tj = Tbiv

2.93

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

18.13 kW

18.18 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

59 W

59 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.01 kW

Annual energy consumption Qhe

9081 kWh

12100 kWh