Login

Subtype

Intelligent Inverter Heat Pump R32- P17A, P17T

Certificate Holder
Guangdong PHNIX Eco-Energy Solutions Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-09
Certification Body
BRE Global Limited
Subtype title
Intelligent Inverter Heat Pump R32- P17A, P17T
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,000 kg

Certification Date
05.09.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

P17A
Configure model
Model name
P17A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.72 kW

20.31 kW

El input

3.68 kW

7.18 kW

COP

4.54

2.83

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

70 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

126 %

Prated

12.61 kW

12.67 kW

SCOP

4.00

3.21

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

11.21 kW

COP Tj = -7°C

3.01

2.27

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.82 kW

6.91 kW

COP Tj = +2°C

3.67

2.81

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.90 kW

7.09 kW

COP Tj = +7°C

4.99

4.63

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.35 kW

7.16 kW

COP Tj = 12°C

6.50

5.76

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

11.15 kW

11.21 kW

COP Tj = Tbiv

3.01

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.66 kW

12.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.83

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

49 °C

49 °C

Poff

19 W

19 W

PTO

19 W

19 W

PSB

19 W

19 W

PCK

59 W

59 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.35 kW

Annual energy consumption Qhe

6512 kWh

8144 kWh

P17T
Configure model
Model name
P17T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.91 kW

20.61 kW

El input

3.92 kW

7.91 kW

COP

4.32

2.61

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

68 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

125 %

Prated

12.89 kW

12.93 kW

SCOP

4.01

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.41 kW

11.43 kW

COP Tj = -7°C

2.96

2.26

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.94 kW

7.05 kW

COP Tj = +2°C

3.73

2.92

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

7.54 kW

7.13 kW

COP Tj = +7°C

5.03

4.16

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

8.26 kW

8.38 kW

COP Tj = 12°C

6.38

5.77

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

11.41 kW

11.43 kW

COP Tj = Tbiv

2.96

2.26

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.85 kW

12.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

25 W

25 W

PTO

25 W

25 W

PSB

25 W

25 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.04 kW

0.00 kW

Annual energy consumption Qhe

6634 kWh

8341 kWh